Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery

被引:18
|
作者
Nordgaard, Havard B. [1 ]
Vitale, Nicola [2 ]
Astudillo, Rafael [2 ]
Renzulli, Attilio [4 ]
Romundstad, Pal [3 ]
Haaverstad, Rune [1 ,5 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7489 Trondheim, Norway
[2] St Olavs Univ Hosp, Dept Cardiothorac Surg, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Publ Hlth, N-7489 Trondheim, Norway
[4] Univ Magna Grecia, Dept Cardiac Surg, Catanzaro, Italy
[5] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
CABG; Coronary graft assessment; Flowmetry; Pulsatile index; PI; Transit-time; FLOW MEASUREMENT; OFF-PUMP; BLOOD-FLOW; VALIDATION; PATENCY;
D O I
10.1016/j.ejcts.2009.11.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement is widely accepted as an intra-operative assessment in coronary artery bypass grafting (CABG). However, the two most commonly applied flowmeters, manufactured by MediStim ASA and Transonic Inc., have different default filter settings of 20 and 10 Hz, respectively. This may cause different flow measurements, which will influence the reported results. The aim was to compare pulsatility index (PI) values recorded by the MediStim and Transonic flowmeters in two different clinical settings: (1) analysis of the flow patterns recorded simultaneously by both flowmeters in the same CABGs; and (2) evaluation of flow patterns under different levels of filter settings in the same grafts. Methods: Graft flow and PI were measured using the two different flowmeters simultaneously in 19 bypass grafts. Finally, eight grafts were assessed under different digital filter settings at 5, 10, 20, 30, 50 and 100 Hz. Results: The Transonic flowmeter provided substantially lower PI as compared with the MediStim flowmeter. By increasing the filter setting in the flowmeter, PI increased considerably. Conclusions: The MediStim flowmeter displayed a lower PI than the Transonic, due to a lower filter setting. In the Transonic, flow signals are filtered at a lower level, rendering a 'smoother' pattern of flow curves. Because different filter settings determine different PIs, caution must be taken when flow values and flowmeters are compared. The type of flowmeter should be indicated whenever graft flow measurements and derived indexes are provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 50 条
  • [21] Intraoperative assessment of grafts in coronary revascularization using the transit-time flowmetry method (TTF)
    Zelazny, Piotr
    Szapiel, Grzegorz
    Witt-Majchrzak, Anna
    Buzun, Leszek
    Dmyterko, Andrzej
    Kuklinski, Maciej
    Morozow, Lew
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2010, 7 (01): : 12 - 17
  • [22] Neurocognitive Function in Patients Undergoing Coronary Artery Bypass Graft Surgery With Cardiopulmonary Bypass: The Effect of Two Different Rewarming Strategies
    Sahu, Bikash
    Chauhan, Sandeep
    Kiran, Usha
    Bisoi, Akshay
    Lakshmy, Ramakrishnan
    Selvaraj, Thiruvenkadam
    Nehra, Ashima
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2009, 23 (01) : 14 - 21
  • [23] Prediction of cerebral infarction after bypass surgery in adult moyamoya disease: using pulsatility index on TCD
    Ding, Jiangbo
    Chang, Xuying
    Ma, Peiyu
    Yang, Guangwu
    Zhang, Ruoyu
    Li, Yuanyuan
    Lei, Ting
    Mu, Linjie
    Zhang, Xingkui
    Li, Zhigao
    Tang, Jinwei
    Tang, Zhiwei
    BMC NEUROLOGY, 2024, 24 (01)
  • [24] Transit time flow measurement in coronary artery bypass grafting: For every patient and every surgeon
    Sandner, Sigrid
    Salerno, Tomas
    Gaudino, Mario F. L.
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (12) : 4456 - 4459
  • [25] Relation of Fractional Flow Reserve With Transit Time Coronary Artery Bypass Graft Flow Measurement
    Noda, Mika
    Takami, Yoshiyuki
    Amano, Kentaro
    Sakurai, Yusuke
    Akita, Kiyotoshi
    Maekawa, Atsuo
    Takagi, Yasushi
    ANNALS OF THORACIC SURGERY, 2021, 111 (01): : 134 - 140
  • [26] Relation of quantitative flow ratio with transit time coronary artery bypass graft flow measurement
    Chen, Cong
    Zhao, Yang
    Li, Wei
    Zhang, Kui
    Dang, Haiming
    Liu, Taoshuai
    Song, Yue
    Zheng, Jubing
    Dong, Ran
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [27] Techniques and standards in intraoperative graft verification by transit time flow measurement after coronary artery bypass graft surgery: a critical review
    Niclauss, Lars
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 51 (01) : 26 - 33
  • [28] The study of using infrared thermal image to assist surgery of coronary artery bypass
    Chang Chia-Jui
    Tsai Chien-Sung
    Tang Shiang-Feng
    Yang Chi-Shih
    Lin Wen-Jen
    Liu Chiang-Lung
    Chen Tzu-Chiang
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2018, 37 (01) : 1 - 7
  • [29] Preserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation
    Nakajima, Hiroyuki
    Iguchi, Atsushi
    Tabata, Mimiko
    Kambe, Masaru
    Ikeda, Masahiro
    Uwabe, Kazuhiko
    Asakura, Toshihisa
    Niinami, Hiroshi
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
  • [30] The Impact of Intraoperative Transit-Time Flow Measurement on Off-Pump and On-Pump Bypass Surgery Based on Three Months: A Propensity Score Matching Study
    Calik, Eyup Serhat
    Arslan, Umit
    HEART SURGERY FORUM, 2024, 27 (11): : E1339 - E1350