Pulsatility index variations using two different transit-time flowmeters in coronary artery bypass surgery

被引:18
作者
Nordgaard, Havard B. [1 ]
Vitale, Nicola [2 ]
Astudillo, Rafael [2 ]
Renzulli, Attilio [4 ]
Romundstad, Pal [3 ]
Haaverstad, Rune [1 ,5 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7489 Trondheim, Norway
[2] St Olavs Univ Hosp, Dept Cardiothorac Surg, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Publ Hlth, N-7489 Trondheim, Norway
[4] Univ Magna Grecia, Dept Cardiac Surg, Catanzaro, Italy
[5] Univ Bergen, Dept Surg Sci, Bergen, Norway
关键词
CABG; Coronary graft assessment; Flowmetry; Pulsatile index; PI; Transit-time; FLOW MEASUREMENT; OFF-PUMP; BLOOD-FLOW; VALIDATION; PATENCY;
D O I
10.1016/j.ejcts.2009.11.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Transit-time flow measurement is widely accepted as an intra-operative assessment in coronary artery bypass grafting (CABG). However, the two most commonly applied flowmeters, manufactured by MediStim ASA and Transonic Inc., have different default filter settings of 20 and 10 Hz, respectively. This may cause different flow measurements, which will influence the reported results. The aim was to compare pulsatility index (PI) values recorded by the MediStim and Transonic flowmeters in two different clinical settings: (1) analysis of the flow patterns recorded simultaneously by both flowmeters in the same CABGs; and (2) evaluation of flow patterns under different levels of filter settings in the same grafts. Methods: Graft flow and PI were measured using the two different flowmeters simultaneously in 19 bypass grafts. Finally, eight grafts were assessed under different digital filter settings at 5, 10, 20, 30, 50 and 100 Hz. Results: The Transonic flowmeter provided substantially lower PI as compared with the MediStim flowmeter. By increasing the filter setting in the flowmeter, PI increased considerably. Conclusions: The MediStim flowmeter displayed a lower PI than the Transonic, due to a lower filter setting. In the Transonic, flow signals are filtered at a lower level, rendering a 'smoother' pattern of flow curves. Because different filter settings determine different PIs, caution must be taken when flow values and flowmeters are compared. The type of flowmeter should be indicated whenever graft flow measurements and derived indexes are provided. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1063 / 1067
页数:5
相关论文
共 22 条
[1]   Pulsatility index determination by flowmeter measurement: A new indicator for vascular resistance? [J].
Aleksic, M ;
Heckenkamp, J ;
Gawenda, M ;
Brunkwall, J .
EUROPEAN SURGICAL RESEARCH, 2004, 36 (06) :345-349
[2]   The impact of intraoperative transit time flow measurement on the results of on-pump coronary surgery [J].
Becit, Necip ;
Erkut, Bitgehan ;
Ceviz, Munacettin ;
Unlu, Yahya ;
Colak, Abdurrahim ;
Kocak, Hikmet .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 32 (02) :313-318
[3]   Transit time flow measurement: Experimental validation and comparison of three different systems [J].
Beldi, G ;
Bosshard, A ;
Hess, OM ;
Althaus, U ;
Walpoth, BH .
ANNALS OF THORACIC SURGERY, 2000, 70 (01) :212-217
[4]   Pre-clinical validation of a new intra-operative "dual beam Doppler" blood flowmeter in an artificial circuit [J].
Cikirikcioglu, M ;
Cikirikcioglu, YB ;
Khabiri, E ;
Djebaili, MK ;
Kalangos, A ;
Walpoth, BH .
HEART SURGERY FORUM, 2006, 9 (01) :E499-E505
[5]   Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting [J].
D'Ancona, G ;
Karamanoukian, HL ;
Ricci, M ;
Schmid, S ;
Bergsland, J ;
Salerno, TA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) :287-293
[6]   Is intraoperative measurement of coronary blood flow a good predictor of graft patency? [J].
D'Ancona, G ;
Karamanoukian, HL ;
Bergsland, J .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (05) :1075-1076
[7]   Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery [J].
Di Giammarco, Gabriele ;
Pano, Marco ;
Cirmeni, Sergio ;
Pelini, Piero ;
Vitolla, Giuseppe ;
Di Mauro, Michele .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (03) :468-474
[8]   THE RELATIONSHIP BETWEEN ULTRASONIC PULSATILITY INDEX AND PROXIMAL ARTERIAL-STENOSIS IN A CANINE MODEL [J].
EVANS, DH ;
BARRIE, WW ;
ASHER, MJ ;
BENTLEY, S ;
BELL, PRF .
CIRCULATION RESEARCH, 1980, 46 (04) :470-475
[9]  
Goel P., 2003, IND J THORAC CARDIOV, V19, P108
[10]   ARTERIAL ASSESSMENT BY DOPPLER-SHIFT ULTRASOUND [J].
GOSLING, RG ;
KING, DH .
PROCEEDINGS OF THE ROYAL SOCIETY OF MEDICINE-LONDON, 1974, 67 (06) :447-449