Effect of storage medium and aging duration on mechanical properties of self-adhesive resin-based cements

被引:5
作者
Liebermann, Anja [1 ]
Ilie, Nicoleta [2 ]
Roos, Malgorzata [3 ]
Stawarczyk, Bogna [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dent Sch, Dept Prosthodont, Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Dent Sch, Dept Operat Restorat Dent Periodontol & Pedodont, Munich, Germany
[3] Univ Zurich, Epidemiol Biostat & Prevent Inst, Dept Biostat, Zurich, Switzerland
关键词
Artificial saliva; Distilled water; Martens hardness; Physiological saliva; Self-adhesive resin-based cement; Sodium chloride; DENTAL COMPOSITES; HUMAN SALIVA; IN-VITRO; ARTIFICIAL SALIVA; WATER SORPTION; BOND STRENGTH; HARDNESS; SOLUBILITY; MONOMERS; ENAMEL;
D O I
10.5301/jabfm.5000362
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background: The aim of this study was to investigate the effects of storage medium and aging duration on Martens hardness (HM) and indentation modulus (E-IT) of self-adhesive resin-based cements (SARCs). Methods: A total of 416 discs were fabricated from 8 SARCs (n = 52 per SARC): (i) BeautyCem (BEA), (ii) Bifix SE (BIF), (iii) Clearfil SA Cement Automix (CLE), (iv) RelyX Unicem2 Automix (RXU), (v) SeT (SET), (vi) SmartCem 2 (SMC), (vii) SoloCem (SOC) and (viii) SpeedCEM (SPC). The specimens were ground and stored in (a) physiological saliva, (b) artificial saliva, (c) sodium chloride and (d) distilled water, at 37 degrees C for 1, 7, 14, 28, 90 and 180 days. Non-aged specimens (3 hours after photo-initiation) of each SARC acted as control groups. HM and E-IT were assessed using a universal hardness testing machine. Data were analyzed using Kolmogorov-Smirnov and Kruskal-Wallis tests and paired t-test, and 3-, 2- and 1-way ANOVA with post hoc Scheffe test (p<0.05). Results: SARC materials exerted the highest influence on HM and E-IT values (p<0.001, partial eta squared [eta(2)(P)] = 0.753 and 0.433, respectively), closely followed by aging duration (p<0.001, eta(2)(P) = 0.516 and 0.255) and storage medium (p< 0.001, eta(2)(P)= 0.043 and 0.033). The interaction effect of the combinations of the 3 independent parameters was also significant (p< 0.001, eta(2)(P) = 0.163 and 0.133). The lowest initial HM and E-IT was presented by CLE, followed by SET and SPC; highest HM was for BIF, followed by RXU and SMC. SET gave a greater HM and E-IT percentage decrease than SOC, SPC, BEA, SMC, RXU or CLE. Conclusions: Aging duration is a major factor affecting the micromechanical properties of SARCs, while storage medium was shown to have a significant but minor role.
引用
收藏
页码:E206 / E214
页数:9
相关论文
共 50 条
[41]   Setting characteristics and mechanical properties of self-adhesive resin luting agents [J].
Pilo, Raphael ;
Papadogiannis, Dimitris ;
Zinelis, Spiros ;
Eliades, George .
DENTAL MATERIALS, 2017, 33 (03) :344-357
[42]   The effect of curing mode on extent of polymerization and microhardness of dual-cured, self-adhesive resin cements [J].
Cadenaro, Milena ;
Navarra, Chiara Ottavia ;
Antoniolli, Francesca ;
Mazzoni, Annalisa ;
Di Lenarda, Roberto ;
Rueggeberg, Frederick Allen ;
Breschi, Lorenzo .
AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (01) :14-18
[43]   Effect of root canal sealers on bond strength of fibreglass posts cemented with self-adhesive resin cements [J].
Cecchin, D. ;
Farina, A. P. ;
Souza, M. A. ;
Carlini-Junior, B. ;
Ferraz, C. C. R. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (04) :314-320
[44]   pH neutralization and influence on mechanical strength in self-adhesive resin luting agents [J].
Zorzin, Jose ;
Petschelt, Anselm ;
Ebert, Johannes ;
Lohbauer, Ulrich .
DENTAL MATERIALS, 2012, 28 (06) :672-679
[45]   Titanium dioxide nanotubes addition to self-adhesive resin cement: Effect on physical and biological properties [J].
Ramos-Tonello, Carla M. ;
Lisboa-Filho, Paulo N. ;
Arruda, Larisa B. ;
Tokuhara, Cintia K. ;
Oliveira, Rodrigo C. ;
Furuse, Adilson Y. ;
Rubo, Jose H. ;
Borges, Ana Flavia S. .
DENTAL MATERIALS, 2017, 33 (07) :866-875
[46]   Bonding Effectiveness of a Self-adhesive Resin-based Luting Cement to Dentin After Provisional Cement Contamination [J].
Bagis, Bora ;
Bagis, Yildirim H. ;
Hasanreisoglu, Ufuk .
JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (06) :543-550
[47]   Adhesive Durability Inside the Root Canal Using Self-adhesive Resin Cements for Luting Fiber Posts [J].
Bitter, K. ;
Maletic, A. ;
Neumann, K. ;
Breschi, L. ;
Sterzenbach, G. ;
Taschner, M. .
OPERATIVE DENTISTRY, 2017, 42 (06) :E167-E176
[48]   Influence of ultrasound application on inlays luting with self-adhesive resin cements [J].
Cantoro, Amerigo ;
Goracci, Cecilia ;
Coniglio, Ivanovic ;
Magni, Elisa ;
Polimeni, Antonella ;
Ferrari, Marco .
CLINICAL ORAL INVESTIGATIONS, 2011, 15 (05) :617-623
[49]   Hygroscopic expansion of self-adhesive resin cements and the integrity of all-ceramic crowns [J].
Kirsten, Magdalena ;
Matta, Ragai Edward ;
Belli, Renan ;
Lohbauer, Ulrich ;
Wichmann, Manfred ;
Petschelt, Anselm ;
Zorzin, Jose .
DENTAL MATERIALS, 2018, 34 (08) :1102-1111
[50]   Does Silane Application Affect Bond Strength Between Self-Adhesive Resin Cements and Feldspathic Porcelain? [J].
Thiranukoon, Pakpilai ;
Klaisiri, Awiruth ;
Sriamporn, Tool ;
Swasdison, Somporn ;
Thamrongananskul, Niyom .
JOURNAL OF COMPOSITES SCIENCE, 2025, 9 (02)