Reproducibility and validity of the assessment of clinical furcation parameters as related to different probes

被引:26
作者
Eickholz, P [1 ]
Kim, TS [1 ]
机构
[1] Univ Heidelberg, Sch Dent, Dept Operat Dent & Periodontol, Heidelberg, Germany
关键词
furcation/diagnosis; periodontal probes; reproducibility of results;
D O I
10.1902/jop.1998.69.3.328
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
THE AIM OF THIS STUDY WAS To investigate the reliability of the assessment of clinical furcation parameters (horizontal attachment levels [CAL-H], class of furcation invasion). Replicate measurements of CAL-H and furcation class were performed within 14 days in 420 molars of 105 patients with advanced periodontitis using a Nabers- (n = 50), a TPS- (n = 30) and a PCPUNC15-probe (n = 25). Validity of clinical assessments was assessed by intrasurgical measurements. The standard deviation of single measurements Cs) was calculated as a measure of the reproducibility of CAL-H measurements and weighted kappa-coefficients (kappa(w)) to estimate the agreement of furcation class assessments. The s ranged from 0.55 to 1.13 nam (Nabers), 0.55 to 1.02 mm (TPS), and 0.58 to 1.11 mm (PUNC15). For all probes, a statistically significantly smaller measurement error was observed in buccal and lingual sites than in mesiolingual and distolingual furcations (P < 0.005). The kappa(w) ranged from 0.59 to 0.89 (Nabers), 0.50 to 0.80 (TPS), and 0.53 to 0.72 (PCPUNC15). Multiple linear regression analysis identified distolingual location, probing depth (PD) and CAL-H as factors influencing the variability of CAL-H measurements. Whereas there was no statistically significant difference between pre-and intrasurgical CAL-H measurements using the Nabers probe, the TPS and PCPUNC15 probe underestimated CAL-H for distolingual furcations (P < 0.025). Using the Nabers probe, no asymmetries between pre- and intrasurgically obtained class of furcation involvement were revealed, while the TPS and PCPUNC15 probe underestimated furcation degrees (P < 0.1). Multiple linear regression analysis identified distolingual location and height of furcation, as well as PD, vertical attachment level (CAL-V) and type of probe, as factors influencing the validity of CAL-H measurements. Clinical diagnosis of furcation lesions using the 3 mm incrementally marked Nabers probe provides reproducible and valid information about furcation invasion.
引用
收藏
页码:328 / 336
页数:9
相关论文
共 35 条
[1]  
Altman D, 1991, PRACTICAL STAT MED R, P211
[2]  
[Anonymous], INT J PERIODONTICS R
[3]  
ARMITAGE P, 1987, STAT METHODS MED RES, P210
[4]   REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS [J].
BADERSTEN, A ;
NILVEUS, R ;
EGELBERG, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) :475-485
[5]   CLASS-II FURCATIONS TREATED BY GUIDED TISSUE REGENERATION IN HUMANS - CASE-REPORTS [J].
CAFFESSE, RG ;
SMITH, BA ;
DUFF, B ;
MORRISON, EC ;
MERRILL, D ;
BECKER, W .
JOURNAL OF PERIODONTOLOGY, 1990, 61 (08) :510-514
[6]  
CLEMMER BA, 1974, J PERIODONT RES S14, V9, P118
[7]   FALSE POSITIVE RATES IN THE DETERMINATION OF CHANGES IN PROBING DEPTH-RELATED PERIODONTAL MEASUREMENTS [J].
COHEN, ME ;
RALLS, SA .
JOURNAL OF PERIODONTAL RESEARCH, 1988, 23 (03) :161-165
[8]   POWER AND SAMPLE-SIZE CALCULATIONS - A REVIEW AND COMPUTER-PROGRAM [J].
DUPONT, WD ;
PLUMMER, WD .
CONTROLLED CLINICAL TRIALS, 1990, 11 (02) :116-128
[9]   THE RELIABILITY OF FURCATION MEASUREMENTS [J].
EICKHOLZ, P ;
STAEHLE, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1994, 21 (09) :611-614
[10]  
Eickholz P, 1991, Dtsch Zahnarztl Z, V46, P356