Screening mammography detected cancers: Sensitivity of a computer-aided detection system applied to full-field digital mammograms

被引:58
作者
Yang, Sang Kyu
Moon, Woo Kyung
Cho, Nariya
Park, Jeong Seon
Cha, Joo Hee
Kim, Sun Mi
Kim, Seung Ja
Im, Jung-Gi
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
[2] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul 100744, South Korea
[3] Seoul Natl Univ Hosp, Clin Res Inst, Seoul 100744, South Korea
[4] Boramae Municipal Hosp, Dept Radiol, Seoul, South Korea
[5] Seoul Natl Univ, Bundang Hosp, Dept Radiol, Bundang, South Korea
关键词
BREAST-CANCER; FILM MAMMOGRAPHY; DIAGNOSIS; MASSES; TRIAL;
D O I
10.1148/radiol.2441060756
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively evaluate the sensitivity of the performance of a computer-aided detection ( CAD) system applied to full-field digital mammograms for detection of breast cancers in a screening group, with histologic findings as the reference standard. Materials and Methods: This study had institutional review board approval, and patient informed consent was waived. A commercially available CAD system was applied to the digital mammograms of 103 women ( mean age, 51 years; range, 35 - 69 years) with 103 breast cancers detected with screening. Sensitivity values of the CAD system according to mammographic appearance, breast composition, and histologic findings were analyzed. Normal mammograms from 100 women ( mean age, 54 years; age range, 35 - 75 years) with no mammographic and clinical abnormality during 2- year follow- up were used to determine false- positive CAD system marks. Differences between the cancer detection rates in fatty and dense breasts for the CAD system were compared by using the X-2 test. Results: The CAD system correctly marked 99 ( 96.1%) of 103 breast cancers. The CAD system marked all 44 breast cancers that manifested as microcalcifications only, all 23 breast cancers that manifested as a mass with microcalcifications, and 32 ( 89%) of 36 lesions that appeared as a mass only. The sensitivity of the CAD system in the fatty breast group was 95% ( 59 of 62) and in the dense breast group was 98% ( 40 of 41) ( P = .537). The CAD system correctly marked all 31 lesions of ductal carcinoma in situ ( DCIS), all 22 lesions of invasive ductal carcinoma with DCIS, the single invasive lobular carcinoma lesion, and 45 ( 92%) of 49 lesions of invasive ductal carcinoma. On normal mammograms, the mean number of false-positive marks per patient was 1.80 ( range, 0 - 10 marks; median, 1 mark). Conclusion: The CAD system can correctly mark most (96.1%) asymptomatic breast cancers detected with digital mammographic screening, with acceptable false- positive marks (1.80 per patient). (c) RSNA, 2007.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 24 条
[1]  
American College of Radiology, 2003, BREAST IM REP DAT SY
[2]   Computer-aided detection in screening mammography: Variability in cues [J].
Baker, JA ;
Lo, JY ;
Delong, DM ;
Floyd, CE .
RADIOLOGY, 2004, 233 (02) :411-417
[3]   Computer-aided detection in direct digital full-field mammography: initial results [J].
Baum, F ;
Fischer, U ;
Obenauer, S ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (12) :3015-3017
[4]   Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection [J].
Birdwell, RL ;
Ikeda, DM ;
O'Shaughnessy, KF ;
Sickles, EA .
RADIOLOGY, 2001, 219 (01) :192-202
[5]   Evaluation of breast cancer with a computer-aided detection system by mammographic appearance and histopathology [J].
Brem, RF ;
Rapelyea, JA ;
Zisman, G ;
Hoffmeister, JW ;
DeSimio, MP .
CANCER, 2005, 104 (05) :931-935
[6]   Impact of breast density on computer-aided detection for breast cancer [J].
Brem, RF ;
Hoffmeister, JW ;
Rapelyea, JA ;
Zisman, G ;
Mohtashemi, K ;
Jindal, G ;
DiSimio, MP ;
Rogers, SK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) :439-444
[7]   Improvement in sensitivity of screening mammography with computer-aided detection: A multiinstitutional trial [J].
Brem, RF ;
Baum, J ;
Lechner, M ;
Kaplan, S ;
Souders, S ;
Naul, LG ;
Hoffmeister, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) :687-693
[8]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[9]   Invasive lobular carcinoma of the breast: Mammographic characteristics and computer-aided detection [J].
Evans, WP ;
Burhenne, LJW ;
Laurie, L ;
O'Shaughnessy, KF ;
Castellino, RA .
RADIOLOGY, 2002, 225 (01) :182-189
[10]   Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center [J].
Freer, TW ;
Ulissey, MJ .
RADIOLOGY, 2001, 220 (03) :781-786