500 kW supercritical CO2 power generation system for waste heat recovery: System design and compressor performance test results

被引:28
作者
Cha, Jae Eun [1 ]
Park, Joo Hyun [1 ]
Lee, Gibbeum [1 ]
Seo, Han [1 ]
Lee, Sunil [1 ]
Chung, Heung-June [1 ]
Lee, Si Woo [2 ]
机构
[1] Korea Atom Energy Res Inst, Daejeon 34057, South Korea
[2] Jinsol Turbo, Daejeon 305509, South Korea
关键词
Carbon dioxide (CO2); Brayton cycle; Waste heat recovery; Supercritical; RECOMPRESSION CYCLE; BRAYTON CYCLES; RANKINE CYCLES; REACTOR;
D O I
10.1016/j.applthermaleng.2021.117028
中图分类号
O414.1 [热力学];
学科分类号
摘要
The supercritical CO2 Brayton cycle has received attention as a next generation power conversion system. However, technical challenges that relate to the design and operation of the system remain to be overcome. In particular, achieving turbomachinery operation with design points is imperative to demonstrate the feasibility of the technology. This study aims to provide the current research status of the supercritical CO2 power generation system in KAERI, with a focus on the detailed design of the system and operation of the compressor. In this study, cycle design (a simple recuperated cycle layout) of the system was developed using an in-house code for the optimization of a pilot plant of a 500 kW supercritical CO2 power generation system for waste heat recovery. A thermal efficiency of 16.5% of the proposed cycle was achieved. In addition, the detailed design of key components, such as turbomachines and heat exchangers, was developed. Furthermore, the first-step configuration, a compressor performance test loop, of the supercritical CO2 power generation system pilot plant was accomplished. The compressor was designed and manufactured as a hermetic system for the supercritical CO2 power generation system. A compressor performance test was conducted to verify the target performance of the compressor. The operation of the compressor at the design point was achieved during the test; the compressor inlet was 33 degrees C at 7.68 MPa, and the compressor rotational speed was 34200 rpm; its efficiency was 83.7%, and the pressure ratio was 1.756.
引用
收藏
页数:15
相关论文
共 56 条
[1]   A comparative performance analysis and thermo-sustainability indicators of modified low-heat organic Rankine cycles (ORCs): An exergy-based procedure [J].
Abam, F. I. ;
Ekwe, E. B. ;
Effiom, S. O. ;
Ndukwu, M. C. .
ENERGY REPORTS, 2018, 4 :110-118
[2]   REVIEW OF SUPERCRITICAL CO2 POWER CYCLE TECHNOLOGY AND CURRENT STATUS OF RESEARCH AND DEVELOPMENT [J].
Ahn, Yoonhan ;
Bae, Seong Jun ;
Kim, Minseok ;
Cho, Seong Kuk ;
Baik, Seungjoon ;
Lee, Jeong Ik ;
Cha, Jae Eun .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2015, 47 (06) :647-661
[3]   Planning for Successful Transients and Trips in a 1MWe-Scale High-Temperature sCO2 Test Loop [J].
Allison, Timothy C. ;
Moore, J. Jeffrey ;
Hofer, Doug ;
Towler, Meera Day ;
Thorp, Joseph .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2019, 141 (06)
[4]  
[Anonymous], 2010, ASME B31.1
[5]  
[Anonymous], 2014, 4 INT S SUP CO2 POW
[6]  
[Anonymous], 2012, SAND2012-9546
[7]  
[Anonymous], 2007, NIST REFERENCE FLUID
[8]  
Aritomi Masanori, 2011, Journal of Power and Energy Systems, V5, P45, DOI 10.1299/jpes.5.45
[9]   Preliminary studies of compact Brayton cycle performance for Small Modular High Temperature Gas-cooled Reactor system [J].
Bae, Seong Jun ;
Lee, Jekyoung ;
Ahn, Yoonhan ;
Lee, Jeong Ik .
ANNALS OF NUCLEAR ENERGY, 2015, 75 :11-19
[10]   Preliminary assessment of sCO2 power cycles for application to CSP Solar Tower plants [J].
Binotti, Marco ;
Astolfi, Marco ;
Campanari, Stefano ;
Manzolini, Giampaolo ;
Silva, Paolo .
8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 :1116-1122