Robust arterial input function surrogate measurement from the superior sagittal sinus complex signal for fast dynamic contrast-enhanced MRI in the brain

被引:1
作者
Bourassa-Moreau, Benoit [1 ]
Lebel, Rejean [1 ]
Gilbert, Guillaume [2 ]
Mathieu, David [3 ,4 ]
Lepage, Martin [1 ,4 ]
机构
[1] Univ Sherbrooke, Ctr Imagerie Mol Sherbrooke, Dept Med Nucl & Radiobiol, Sherbrooke, PQ, Canada
[2] Philips Healthcare Canada, MR Clin Sci, Markham, ON, Canada
[3] Univ Sherbrooke, Dept Chirurg, Serv Neurochirurg, Sherbrooke, PQ, Canada
[4] Ctr Rech Ctr Hosp Univ Sherbrooke, Ctr Integre Sante & Serv Sociaux Estrie, Sherbrooke, PQ, Canada
关键词
arterial input function; brain perfusion; complex signal; dynamic contrast-enhanced MRI; inflow; superior sagittal sinus; DCE-MRI; BLOOD; PARAMETERS; MAGNITUDE; PERFUSION; INFLOW;
D O I
10.1002/mrm.28922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurately estimating the arterial input function for dynamic contrast-enhanced MRI is challenging. An arterial input function is typically determined from signal magnitude changes related to a contrast agent, often leading to underestimation of peak concentrations. Alternatively, signal phase recovers the accurate peak concentration for straight vessels but suffers from high noise. A recent method proposed to fit the signal in the complex plane by combining the advantages of the previous 2 methods. The purpose of this work is to refine this complex-based method to determine the venous output function (VOF), an arterial input function surrogate, from the superior sagittal sinus. Methods: We propose a state-of-the-art complex-based method that includes direct compensation for blood inflow and signal phase correction accounting for the curvature of the superior sagittal sinus, generally assumed collinear with B-0. We compared the magnitude-, phase-, and complex-based VOF determination methods against various simulated biases as well as for 29 brain metastases patients. Results: Angulation of the superior sagittal sinus relative to B-0 varied widely within patients, and its effect on the signal phase caused an underestimation of peak concentrations of up to 65%. Correction significantly increased the VOF peak concentration for the phase-and complex-based VOFs in the cohort. The phase-based method recovered accurate peak concentrations but lacked precision in the tail of the VOF. Our complex-based VOF completely recovered the effect of inflow and resulted in a high-peak concentration with limited noise. Conclusion: The new complex-based method resulted in high-quality VOF robust against superior sagittal sinus curvature and variations in patient positioning.
引用
收藏
页码:3052 / 3066
页数:15
相关论文
共 27 条
[1]  
Akbudak E., 2004, Syllabus of the ISMRM workshop on Quantitative Cerebral Perfusion Imaging Using MRI: A Technical Perspective, P10
[2]  
Bourassa-Moreau B., 2017, P 25 ANN M ISMRM HON P 25 ANN M ISMRM HON, P1902
[3]  
Bourassa-Moreau B., 2020, P 28 ANN M ISMRM VIR
[4]  
Bourassa-Moreau B., 2018, P 26 ANN M ISMRM PAR P 26 ANN M ISMRM PAR, P493
[5]   Bolus delay and dispersion in perfusion MRI: Implications for tissue predictor models in stroke [J].
Calamante, F ;
Willats, L ;
Gadian, DG ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1180-1185
[6]   Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI [J].
Cheng, Hai-Ling Margaret .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :736-743
[7]   Determining and optimizing the precision of quantitative measurements of perfusion from dynamic contrast enhanced MRI [J].
Dale, BM ;
Jesberger, JA ;
Lewin, JS ;
Hillenbrand, CM ;
Duerk, JL .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (05) :575-584
[8]   Phantom Validation of DCE-MRI Magnitude and Phase-Based Vascular Input Function Measurements [J].
Foltz, Warren ;
Driscoll, Brandon ;
Lee, Sangjune Laurence ;
Nayak, Krishna ;
Nallapareddy, Naren ;
Fatemi, Ali ;
Menard, Cynthia ;
Coolens, Catherine ;
Chung, Caroline .
TOMOGRAPHY, 2019, 5 (01) :77-89
[9]  
Foottit C., 2011, P 19 ANN M ISMRM MON P 19 ANN M ISMRM MON, P2038
[10]   Determination of the Venous Output Function From MR Signal Phase: Feasibility for Quantitative DCE-MRI in Human Brain [J].
Foottit, Claire ;
Cron, Greg O. ;
Hogan, Matthew J. ;
Nguyen, Thanh Binh ;
Cameron, Ian .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :772-781