Comparison of two- and three-dimensional camera systems in laparoscopic performance: a novel 3D system with one camera

被引:86
作者
Kong, Seong-Ho [1 ]
Oh, Byung-Mo [2 ]
Yoon, Hongman [1 ]
Ahn, Hye Seong [1 ]
Lee, Hyuk-Joon [1 ]
Chung, Sun Geun [2 ]
Shiraishi, Norio [3 ]
Kitano, Seigo [3 ]
Yang, Han-Kwang [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Surg, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Rehabil Med, Seoul 110744, South Korea
[3] Oita Univ, Fac Med, Dept Surg 1, Oita 87011, Japan
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2010年 / 24卷 / 05期
关键词
Imaging and virtual reality; Surgical; Training; SURGICAL SKILLS; VISION; IMPACT; PRECISION;
D O I
10.1007/s00464-009-0740-8
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study evaluated the effects of a three-dimensional (3D) imaging system on laparoscopy performance compared with the conventional 2D system using a novel one-camera 3D system. In this study, 21 novices and 6 experienced surgeons performed two tasks with 2D and 3D systems in 4 consecutive days. Performance time and error as well as subjective parameters such as depth perception and visual discomforts were assessed in each session. Electromyography was used to evaluate the usage of muscles. The 3D system provided significantly greater depth perception than the 2D system. The errors during the two tasks were significantly lower with 3D system in novice group, but performance time was not different between the 2D and 3D systems. The novices had more dizziness with the 3D system in first 2 days. However, the severity of dizziness was minimal (less than 2 of 10) and overcome with the passage of time. About 54% of the novices and 80% of the experienced surgeons preferred the 3D system. Electromyography (EMG) showed a tendency toward less usage of the right arm and more usage of the left arm with the 3D system. The new 3D imaging system increased the accuracy of laparoscopy performance, with greater depth perception and only minimal dizziness. The authors expect that the 3D laparoscopic system could provide good depth perception and accuracy in surgery.
引用
收藏
页码:1132 / 1143
页数:12
相关论文
共 31 条
[1]  
Becker H, 1993, Endosc Surg Allied Technol, V1, P40
[2]   A comparison of forearm and thumb muscle electromyographic responses to the use of laparoscopic instruments with either a finger grasp or a palm grasp [J].
Berguer, R ;
Gerber, S ;
Kilpatrick, G ;
Remler, M ;
Beckley, D .
ERGONOMICS, 1999, 42 (12) :1634-1645
[3]   Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery [J].
Berguer, R ;
Smith, WD ;
Chung, YH .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (10) :1204-1207
[4]  
BIRKETT DH, 1994, SURG ENDOSC-ULTRAS, V8, P1448
[5]   Computer vision syndrome: A review [J].
Blehm, C ;
Vishnu, S ;
Khattak, A ;
Mitra, S ;
Yee, RW .
SURVEY OF OPHTHALMOLOGY, 2005, 50 (03) :253-262
[6]   Three-dimensional imaging improves surgical performance for both novice and experienced operators using the da Vinci Robot System [J].
Byrn, John C. ;
Schluender, Stefanie ;
Divino, Celia M. ;
Conrad, John ;
Gurland, Brooke ;
Shlasko, Edward ;
Szold, Amir .
AMERICAN JOURNAL OF SURGERY, 2007, 193 (04) :519-522
[7]   Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery [J].
Chan, ACW ;
Chung, SCS ;
Yim, APC ;
Lau, JYW ;
Ng, EKW ;
Li, AKC .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (05) :438-440
[8]   Effect of reduced stereoscopic camera separation on ring placement with a surgical telerobot [J].
Fishman, Jonathan M. ;
Ellis, Stephen R. ;
Hasser, Christopher J. ;
Stern, John D. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (11) :2396-2400
[9]   PicSOr - An objective test of perceptual skill that predicts laparoscopic technical skill in three initial studies of laparoscopic performance [J].
Gallagher, AG ;
Cowie, R ;
Crothers, I ;
Jordan-Black, JA ;
Satava, RM .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2003, 17 (09) :1468-1471
[10]   Can armrests improve comfort and task performance in laparoscopic surgery? [J].
Galleano, R ;
Carter, F ;
Brown, S ;
Frank, T ;
Cuschieri, A .
ANNALS OF SURGERY, 2006, 243 (03) :329-333