摘要
In the present study, an overview of the capacitor bank energizing transients is presented and the means of harmonic mitigation technique are investigated. Capacitor bank connection is essential due to reactive compensation reasons. Transients produced upon of capacitor bank energizing, reach in harmonics, may be harmful for the capacitor and become an increasing concern for both electric utilities and customers since its switching usually occurs quite frequently. We know that power factor correction capacitors are sensitive to harmonics and one factor of the failures of power capacitors indicates the prime odd harmonics like 5th, 7th, 11th, 13th harmonics. A time domain simulation using PSCAD/EMTDC was performed to predict the harmonic spectrum of the distorted voltage waveform in a real 11kV Romanian distribution subsystem.
引用
收藏
页码:1087 / +
页数:3
相关论文
共 50 条
  • [1] Mitigation of Capacitor Bank Switching Transients by Using SVCs in Large Plants Instead of Capacitor bank and Circuit Breaker
    Taherzadeh, M.
    Rostaminia, R.
    Joorabian, M.
    Saniei, M.
    4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), 2013, : 321 - 327
  • [2] Solid-State Capacitor Switching Transient Limiter based on Kalman Filter algorithm for mitigation of capacitor bank switching transients
    Ghanbari, T.
    Farjah, E.
    Naseri, F.
    Tashakor, N.
    Givi, H.
    Khayam, R.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 90 : 1069 - 1081
  • [3] Analysis and Mitigation of Shunt Capacitor Bank Switching Transients on 132 kV Grid Station, Qasimabad Hyderabad
    Katyara, Sunny
    Hashmani, Ashfaque Ahmed
    Chowdhry, Bhawani Shankar
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2015, 34 (03) : 291 - 300
  • [4] Influence of Harmonic on the Protections of Capacitor Bank
    Cen, Xu
    Liu, Shuming
    Li, Qionglin
    Tao, Shun
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 2543 - +
  • [5] Modeling and Mitigation for High Frequency Switching Transients Due to Energization in Offshore Wind Farms
    Xin, Yanli
    Liu, Bo
    Tang, Wenhu
    Wu, Qinghua
    ENERGIES, 2016, 9 (12):
  • [6] Back-to-back capacitor energization transients mitigation: Comparison of pre-insertion inductors versus surge reactors on a 46 kV subtransmission system
    Bohmann, LJ
    Demler, JR
    Barna, BA
    ELECTRIC MACHINES AND POWER SYSTEMS, 1997, 25 (09): : 1023 - 1034
  • [7] Analysis and control of large shunt capacitor bank switching transients
    Das, JC
    Conference Record of 2005 Annual Pulp and Paper Industry Technical Conference, 2005, : 131 - 140
  • [8] Energization transients of shunt reactors
    Wang, X
    Iravani, MR
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1997, 12 (04) : 1626 - 1631
  • [9] Resistive Capacitive Switching Technique for the Mitigation of Power Capacitor Switching Transients
    Yuvraj, Gaikwad J.
    Thorat, A. R.
    2019 8TH IEEE INTERNATIONAL CONFERENCE ON COMPUTATION OF POWER, ENERGY, INFORMATION AND COMMUNICATION (ICCPEIC'19), 2019, : 109 - 112
  • [10] Analysis and control of large-shunt-capacitor-bank switching transients
    Das, JC
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (06) : 1444 - 1451