Aptasensor for label-free square-wave voltammetry detection of potassium ions based on gold nanoparticle amplification

被引:10
作者
Chen, Zhengbo [1 ]
Zhou, Tianhui [1 ]
Zhang, Chenmeng [1 ]
Ma, He [1 ]
Lin, Yuqing [1 ]
Li, Kai [1 ]
机构
[1] Capital Normal Univ, Dept Chem, Beijing 100048, Peoples R China
关键词
G-QUADRUPLEX; DNA; APTAMER; SWITCH; ASSAY; SENSITIVITY; SELECTIVITY; SURFACES; SENSORS;
D O I
10.1039/c4ra05058d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Herein, we present a very simple and label-free square-wave voltammetry (SWV) aptasensor to detect potassium ions (K+), in which a K+-specific aptamer was used as an ion recognition element, and a redox couple [Fe(CN)(6)](3-/4-) as a redox probe. At the bare gold electrode, the redox couple [Fe(CN)(6)](3-/4-) can very easily access the electrode surface to produce a very strong SWV signal. At the K+-specific aptamer/gold electrode surface, in the presence of K+, the single-stranded DNA with guanine (G)-rich sequences could fold into a secondary structure, G-quadruplex, which resulted in less availability for a redox reaction, and led to a smaller SWV current. To improve signal intensity, gold nanoparticles (AuNPs) were anchored to a gold electrode surface which had been previously modified with self-assembled monolayers of p-aminothiophenol. The SWV peak current decreased with K+ concentration, and the plot of the SWV peak current against the logarithm of K+ concentration is linear over the range from 10 pM to 0.1 mu M and 0.5 mu M to 1 mM, with a detection limit of 0.13 pM. The aptasensor also showed a very good selectivity for K+ without being affected by the coexistence of other ions.
引用
收藏
页码:48671 / 48675
页数:5
相关论文
共 38 条
[1]  
[Anonymous], 1973, PURE APPL CHEM, DOI DOI 10.1351/PAC197334010035
[2]   A highly sensitive and selective resonance scattering spectral assay for potassium ion based on aptamer and nanosilver aggregation reactions [J].
Cai, Wei ;
Fan, Yanyan ;
Jiang, Zhiliang ;
Yao, Junen .
TALANTA, 2010, 81 (4-5) :1810-1815
[3]   Electrochemical sensing of DNA using gold nanoparticles [J].
Castaneda, M. T. ;
Alegret, S. ;
Merkoci, A. .
ELECTROANALYSIS, 2007, 19 (7-8) :743-753
[4]   Graphene Fluorescence Resonance Energy Transfer Aptasensor for the Thrombin Detection [J].
Chang, Haixin ;
Tang, Longhua ;
Wang, Ying ;
Jiang, Jianhui ;
Li, Jinghong .
ANALYTICAL CHEMISTRY, 2010, 82 (06) :2341-2346
[5]   Colorimetric detection of potassium ions using aptamer-functionalized gold nanoparticles [J].
Chen, Zhengbo ;
Huang, Yanqin ;
Li, Xiaoxiao ;
Zhou, Tong ;
Ma, He ;
Qiang, Hong ;
Liu, Yifei .
ANALYTICA CHIMICA ACTA, 2013, 787 :189-192
[6]   Label-free dual assay of DNA sequences and potassium ions using an aptamer probe and a molecular light switch complex [J].
Choi, Min Sun ;
Yoon, Minji ;
Baeg, Jin-Ook ;
Kim, Jinheung .
CHEMICAL COMMUNICATIONS, 2009, (47) :7419-7421
[7]   G-quartets 40 years later:: From 5′-GMP to molecular biology and supramolecular chemistry [J].
Davis, JT .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (06) :668-698
[8]   Sensitive Bifunctional Aptamer-Based Electrochemical Biosensor for Small Molecules and Protein [J].
Deng, Chunyan ;
Chen, Jinhua ;
Nie, Lihua ;
Nie, Zhou ;
Yao, Shouzhuo .
ANALYTICAL CHEMISTRY, 2009, 81 (24) :9972-9978
[9]   ORGANIZATION OF AU COLLOIDS AS MONOLAYER FILMS ONTO ITO GLASS SURFACES - APPLICATION OF THE METAL COLLOID FILMS AS BASE INTERFACES TO CONSTRUCT REDOX-ACTIVE MONOLAYERS [J].
DORON, A ;
KATZ, E ;
WILLNER, I .
LANGMUIR, 1995, 11 (04) :1313-1317
[10]   CONTROLLED NUCLEATION FOR REGULATION OF PARTICLE-SIZE IN MONODISPERSE GOLD SUSPENSIONS [J].
FRENS, G .
NATURE-PHYSICAL SCIENCE, 1973, 241 (105) :20-22