Motion artifact reducing reconstruction of 4D CT image data for the analysis of respiratory dynamics

被引:30
作者
Werner, R.
Ehrhardt, J.
Frenzel, T.
Saering, D.
Lu, W.
Low, D.
Handels, H.
机构
[1] Univ Hamburg, Med Ctr Hamburg Eppendorf, Dept Med Informat, D-20246 Hamburg, Germany
[2] AK St Georg Hosp, Hermann Holthusen Inst Radiotherapy, Hamburg, Germany
[3] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO USA
关键词
computed X-ray tomography; 4D CT; computer-assisted image analysis; respiratory motion; lung cancer;
D O I
10.1160/ME9040
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objectives: Respiratory motion represents a major problem in radiotherapy of thoracic and abdominal tumors. Methods for compensation require comprehensive knowledge of underlying dynamics. Therefore, 4D (= 3D + t) CT data can be helpful. But modern CT scanners cannot scan a large region of interest simultaneously. So patients hove to be scanned in segments. Commonly used approaches for reconstructing the data segments into 4D CT images cause motion artifacts. In order to reduce the artifacts, a new method for 4D CT reconstruction is presented. The resulting data sets are used to analyze respiratory motion. Methods. Spatiotemporal CT image sequences of lung cancer patients were acquired using a multi-slice CT in cine mode during free breathing. 4D CT reconstruction was done by optical flow based temporal interpolation. The resulting 4D image data were compared with data generated by the commonly used nearest neighbor reconstruction. Subsequent motion analysis is mainly concerned with tumor mobility. Results: The presented optical flow-based method enables the reconstruction of 3D CT images at arbitrarily chosen points of the patient's breathing cycle. A considerable reduction of motion artifacts has been proven in eight patient data sets. Motion analysis showed that tumor mobility differs strongly between the patients. Conclusions. Due to the proved reduction of motion artifacts, the optical flow-based 4D CT reconstruction offers the possibility of high-quality motion analysis. Because the method is based on an interpolation scheme, it additionally has the potential to enable the reconstruction of 4D CT data from a lesser number of scans.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
[31]   Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET [J].
Feng, Tao ;
Wang, Jizhe ;
Fung, George ;
Tsui, Benjamin .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) :151-168
[32]   Development of a 3D Printed Motion Mechanism for a 4D Respiratory Motion Phantom [J].
Ahmad, Muhammad Akmal ;
Mustaza, Seri Mastura ;
Mokri, Siti Salasiah ;
Azmi, Nor Aniza ;
Ahmad, Rozilawati ;
Ramli, Rizauddin ;
Rahman, Wan Nordiana Wan Abdul ;
Abd Rahni, Ashrani Aizzuddin .
2020 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES 2020): LEADING MODERN HEALTHCARE TECHNOLOGY ENHANCING WELLNESS, 2021, :132-135
[33]   Abdominal organ motion measured using 4D CT [J].
Brandner, Edward D. ;
Wu, Andrew ;
Chen, Hungcheng ;
Heron, Dwight ;
Kalnicki, Shalom ;
Komanduri, Krishna ;
Gerszten, Kristina ;
Burton, Steve ;
Ahmed, Irfan ;
Shou, Zhenyu .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :554-560
[34]   Reducing 4D CT artifacts using optimized sorting based on anatomic similarity [J].
Johnston, Eric ;
Diehn, Maximilian ;
Murphy, James D. ;
Loo, Billy W., Jr. ;
Maxim, Peter G. .
MEDICAL PHYSICS, 2011, 38 (05) :2424-2429
[35]   4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling [J].
Yang, Deshan ;
Lu, Wei ;
Low, Daniel A. ;
Deasy, Joseph O. ;
Hope, Andrew J. ;
El Naqa, Issam .
MEDICAL PHYSICS, 2008, 35 (10) :4577-4590
[36]   REGION BASED 4D TOMOGRAPHIC IMAGE RECONSTRUCTION: APPLICATION TO CARDIAC X-RAY CT [J].
Van Eyndhoven, G. ;
Batenburg, K. J. ;
Sijbers, J. .
2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, :113-117
[37]   Integrated Segmentation and Non-linear Registration for Organ Segmentation and Motion Field Estimation in 4D CT Data [J].
Schmidt-Richberg, A. ;
Handels, H. ;
Ehrhardt, J. .
METHODS OF INFORMATION IN MEDICINE, 2009, 48 (04) :344-349
[38]   An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing [J].
Ehrhardt, Jan ;
Werner, Rene ;
Saering, Dennis ;
Frenzel, Thorsten ;
Lu, Wei ;
Low, Daniel ;
Handels, Heinz .
MEDICAL PHYSICS, 2007, 34 (02) :711-721
[39]   Joint surface reconstruction and 4D deformation estimation from sparse data and prior knowledge for marker-less Respiratory motion tracking [J].
Berkels, Benjamin ;
Bauer, Sebastian ;
Ettl, Svenja ;
Arold, Oliver ;
Hornegger, Joachim ;
Rumpf, Martin .
MEDICAL PHYSICS, 2013, 40 (09)
[40]   Influence of 4D CT Motion Artifacts on Correspondence Model-based 4D Dose Accumulation [J].
Sothmann, Thilo ;
Gauer, Tobias ;
Werner, Rene .
MEDICAL IMAGING 2018: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2018, 10576