摘要
Objectives: Respiratory motion represents a major problem in radiotherapy of thoracic and abdominal tumors. Methods for compensation require comprehensive knowledge of underlying dynamics. Therefore, 4D (= 3D + t) CT data can be helpful. But modern CT scanners cannot scan a large region of interest simultaneously. So patients hove to be scanned in segments. Commonly used approaches for reconstructing the data segments into 4D CT images cause motion artifacts. In order to reduce the artifacts, a new method for 4D CT reconstruction is presented. The resulting data sets are used to analyze respiratory motion. Methods. Spatiotemporal CT image sequences of lung cancer patients were acquired using a multi-slice CT in cine mode during free breathing. 4D CT reconstruction was done by optical flow based temporal interpolation. The resulting 4D image data were compared with data generated by the commonly used nearest neighbor reconstruction. Subsequent motion analysis is mainly concerned with tumor mobility. Results: The presented optical flow-based method enables the reconstruction of 3D CT images at arbitrarily chosen points of the patient's breathing cycle. A considerable reduction of motion artifacts has been proven in eight patient data sets. Motion analysis showed that tumor mobility differs strongly between the patients. Conclusions. Due to the proved reduction of motion artifacts, the optical flow-based 4D CT reconstruction offers the possibility of high-quality motion analysis. Because the method is based on an interpolation scheme, it additionally has the potential to enable the reconstruction of 4D CT data from a lesser number of scans.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
[21]   Reconstruction of 4D deformed CT for moving anatomy [J].
Docef, Alen ;
Murphy, Martin J. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (06) :591-598
[22]   Respiratory motion correction in 4D-PET by simultaneous motion estimation and image reconstruction (SMEIR) [J].
Kalantari, Faraz ;
Li, Tianfang ;
Jin, Mingwu ;
Wang, Jing .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (15) :5639-5661
[23]   AI-Enhanced 4D CT Radiotherapy Planning for Personalized Lung Cancer Treatment with Respiratory Motion Management [J].
Trabelsi, Mariem ;
Ben Salem, Lotfi ;
Romdhane, Hamida ;
Ben-Sellem, Dorra .
INDIAN JOURNAL OF SURGICAL ONCOLOGY, 2025,
[24]   An algorithm for 4D CT image sorting using spatial continuity [J].
Li, Chen ;
Liu, Jie .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (03) :323-333
[25]   Characterisation of Respiratory Motion Extracted from 4D MRI [J].
Abd Rahni, Ashrani Aizzuddin ;
Lewis, Emma ;
Wells, Kevin .
MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
[26]   Evaluation and commissioning of a surface based system for respiratory sensing in 4D CT [J].
Spadea, Maria Francesca ;
Baroni, Guido ;
Gierga, David P. ;
Turcotte, Julie C. ;
Chen, George T. Y. ;
Sharp, Gregory C. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (01) :162-169
[27]   Clinical application of breathing-adapted 4D CT: image quality comparison to conventional 4D CT [J].
Werner, Rene ;
Szkitsak, Juliane ;
Madesta, Frederic ;
Buettgen, Laura ;
Wimmert, Lukas ;
Sentker, Thilo ;
Fietkau, Rainer ;
Haderlein, Marlen ;
Bert, Christoph ;
Gauer, Tobias ;
Hofmann, Christian .
STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (07) :686-691
[28]   Clinical application of breathing-adapted 4D CT: image quality comparison to conventional 4D CT [J].
René Werner ;
Juliane Szkitsak ;
Frederic Madesta ;
Laura Büttgen ;
Lukas Wimmert ;
Thilo Sentker ;
Rainer Fietkau ;
Marlen Haderlein ;
Christoph Bert ;
Tobias Gauer ;
Christian Hofmann .
Strahlentherapie und Onkologie, 2023, 199 :686-691
[29]   Abdominal and pancreatic motion correlation using 4D CT, 4D transponders, and a gating belt [J].
Betancourt, Ricardo ;
Zou, Wei ;
Plastaras, John P. ;
Metz, James M. ;
Teo, Boon-Keng ;
Kassaee, Alireza .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03) :13-24
[30]   Assessment of a quantitative metric for 4D CT artifact evaluation by observer consensus [J].
Castillo, Sarah J. ;
Castillo, Richard ;
Balter, Peter ;
Pan, Tinsu ;
Ibbott, Geoffrey ;
Hobbs, Brian ;
Yuan, Ying ;
Guerrero, Thomas .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03) :190-201