Motion artifact reducing reconstruction of 4D CT image data for the analysis of respiratory dynamics

被引:30
|
作者
Werner, R.
Ehrhardt, J.
Frenzel, T.
Saering, D.
Lu, W.
Low, D.
Handels, H.
机构
[1] Univ Hamburg, Med Ctr Hamburg Eppendorf, Dept Med Informat, D-20246 Hamburg, Germany
[2] AK St Georg Hosp, Hermann Holthusen Inst Radiotherapy, Hamburg, Germany
[3] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO USA
关键词
computed X-ray tomography; 4D CT; computer-assisted image analysis; respiratory motion; lung cancer;
D O I
10.1160/ME9040
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objectives: Respiratory motion represents a major problem in radiotherapy of thoracic and abdominal tumors. Methods for compensation require comprehensive knowledge of underlying dynamics. Therefore, 4D (= 3D + t) CT data can be helpful. But modern CT scanners cannot scan a large region of interest simultaneously. So patients hove to be scanned in segments. Commonly used approaches for reconstructing the data segments into 4D CT images cause motion artifacts. In order to reduce the artifacts, a new method for 4D CT reconstruction is presented. The resulting data sets are used to analyze respiratory motion. Methods. Spatiotemporal CT image sequences of lung cancer patients were acquired using a multi-slice CT in cine mode during free breathing. 4D CT reconstruction was done by optical flow based temporal interpolation. The resulting 4D image data were compared with data generated by the commonly used nearest neighbor reconstruction. Subsequent motion analysis is mainly concerned with tumor mobility. Results: The presented optical flow-based method enables the reconstruction of 3D CT images at arbitrarily chosen points of the patient's breathing cycle. A considerable reduction of motion artifacts has been proven in eight patient data sets. Motion analysis showed that tumor mobility differs strongly between the patients. Conclusions. Due to the proved reduction of motion artifacts, the optical flow-based 4D CT reconstruction offers the possibility of high-quality motion analysis. Because the method is based on an interpolation scheme, it additionally has the potential to enable the reconstruction of 4D CT data from a lesser number of scans.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [1] Analysis of free breathing motion using artifact reduced 4D CT image data
    Ehrhardt, Jan
    Werner, Rene
    Frenzel, Thorsten
    Lu, Wei
    Low, Daniel
    Handels, Heinz
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [2] Compensating respiratory motion in PET image reconstruction using 4D PET/CT
    Qiao, Feng
    Pan, Tinsu
    Clark, John W., Jr.
    Mawlawi, Osama R.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2595 - 2598
  • [3] Analysis of tumor-influenced respiratory dynamics using motion artifact reduced thoracic 4D CT images
    Werner, Ren
    Ehrhardt, Jan
    Frenzel, Thorsten
    Lu, Wei
    Low, Daniel
    Handels, Heinz
    ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 181 - +
  • [4] Modeling respiratory motion for reducing motion artifacts in 4D CT images
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Balter, Peter A.
    Dong, Lei
    MEDICAL PHYSICS, 2013, 40 (04)
  • [5] 4D CT image reconstruction with diffeomorphic motion model
    Hinkle, Jacob
    Szegedi, Martin
    Wang, Brian
    Salter, Bill
    Joshi, Sarang
    MEDICAL IMAGE ANALYSIS, 2012, 16 (06) : 1307 - 1316
  • [6] An iterative image reconstruction algorithm for 4D PET/CT incorporating respiratory motion correction
    Lamare, F.
    Ledesma-Carbayo, M.
    Kontaxakis, G.
    Santos, A.
    Jarritt, P.
    Mawlawi, O.
    Le Rest, C. Cheze
    Visvikis, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S147 - S147
  • [7] 4D POSITRON EMISSION TOMOGRAPHY IMAGE RECONSTRUCTION BASED ON BIOMECHANICAL RESPIRATORY MOTION
    Manescu, Petru
    Ladjal, Hamid
    Touileb, Yazid
    Azencot, Joseph
    Beuve, Michael
    Shariat, Behzad
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 99 - 102
  • [8] Effect of motion estimation methods on respiratory motion compensation in 4D quantitative PET image reconstruction
    Chen, Si
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [9] Respiratory motion-conditioned 4D CT: A method to determine respiratory motion tolerances to reduce motion artifacts during 4D CT acquisition
    Vedam, S
    George, R
    Keall, P
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S204 - S205
  • [10] Modeling respiratory motion for reducing motion artifacts in 4D CT images (vol 40, 041716, 2013)
    Zhang, Yongbin
    Yang, Jinzhong
    Zhang, Lifei
    Court, Laurence E.
    Baiter, Peter A.
    Dong, Lei
    MEDICAL PHYSICS, 2015, 42 (11) : 6768 - 6768