Conceptual design and analysis of a semi-passive containment cooling system for a large concrete containment

被引:47
作者
Byun, CS
Jerng, DW
Todreas, NE
Driscoll, MJ
机构
[1] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
[2] Korea Elect Power Res Inst, Taejon, South Korea
关键词
D O I
10.1016/S0029-5493(00)00228-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An internal evaporator-only (IEO) concept has been developed as a semi-passive containment cooling system for a large dry concrete containment. The function of this system is to keep the containment integrity by maintaining the internal pressure not to exceed ultimate design pressure, i.e. 0.83 MPa (120 psia) in the absence of any other containment cooling following a severe accident, which postulates core damage and hydrogen combustion. The ability of the concept to protect the containment was evaluated for the design basis accident (DBA) large break loss of coolant accident (LB LOCA) and severe accident scenarios (LB LOCA without Emergency Core Cooling System (ECCS) and containment spray flow, 100% zirconium oxidation and complete hydrogen combustion). All were modeled using the GOTHIC computer code. It was concluded that a practical system requiring four IEO loops could be utilized to meet design criteria for severe accident scenarios. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:227 / 242
页数:16
相关论文
共 14 条
[1]  
AHMAD A, 1983, NUREGCR2666
[2]  
American Society of Mechanical Engineers (ASME), 1971, ASME BOIL PRESS VESS
[3]  
[Anonymous], 1987, NUREG1150 USNRC
[4]  
DECACHARD FD, 1997, THERMAL HYDRAULIC MO, P49
[5]  
GEORGE TL, 1997, GOTHIC CONTAINMENT A
[6]  
*IAEA, 1993, STAT ADV CONT SYST N, P752
[7]  
KIM YH, 1998, NITANPTR059
[8]   FLAMMABILITY LIMITS OF HYDROGEN-OXYGEN-DILUENT MIXTURES [J].
KUMAR, RK .
JOURNAL OF FIRE SCIENCES, 1985, 3 (04) :245-262
[9]  
Leiendecker M., 1998, Transactions of the American Nuclear Society, V78, P263
[10]  
LEIENDECKER M, 1997, MITANPTR053