As the surge for renewable and clean energy resources increases, new challenges emerge. One of the challenges related to the use of hydrogen as a clean energy source is safety. In this study, a microwave hydrogen sensor has been presented for detection of hydrogen leakage. An analytical model is developed and the performance of the sensor is investigated using numerical analysis tools. It has been shown that with optimal geometrical parameters of the sensor structure, a wide range of sensitivity levels depending on a wide range of Q-factor can be achieved. Utilizing a palladium disk with a radius of 750 mu m can detect hydrogen with a sensitivity as high as 30 MHz per % hydrogen when g = 10 mu m. Average error between analytical model and numerical results is 0.23%. With reference to this work, it is believed that more compact and sensitive microwave hydrogen sensors will be produced for future uses.
引用
收藏
页数:7
相关论文
共 27 条
[1]  
Abdollahi M, 2019, IEEE C EVOL COMPUTAT, P119, DOI [10.1109/cec.2019.8790259, 10.1109/CEC.2019.8790259]
[2]   Noninvasive Glucose Sensing in Aqueous Solutions Using an Active Split-Ring Resonator [J].
Abdolrazzaghi, Mohammad ;
Katchinskiy, Nir ;
Elezzabi, Abdulhakem Y. ;
Light, Peter E. ;
Daneshmand, Mojgan .
IEEE SENSORS JOURNAL, 2021, 21 (17) :18742-18755
[3]   Microwaves-Based High Sensitivity Sensors for Crack Detection in Metallic Materials [J].
Albishi, Ali M. ;
Ramahi, Omar M. .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (05) :1864-1872
[4]  
[Anonymous], 2001, Coplanar Waveguide Circuits, Components, and Systems
[5]   Material Characterization Using Complementary Split-Ring Resonators [J].
Boybay, Muhammed Said ;
Ramahi, Omar M. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2012, 61 (11) :3039-3046
[6]   Study on Pd functionalization of microcantilever for hydrogen detection promotion [J].
Chou, Yen-I ;
Chiang, Hsu-Cheng ;
Wang, Chi-Chuan .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (01) :72-78
[7]   SOLID-STATE SENSORS FOR TRACE HYDROGEN GAS-DETECTION [J].
CHRISTOFIDES, C ;
MANDELIS, A .
JOURNAL OF APPLIED PHYSICS, 1990, 68 (06) :R1-R30
[8]   Detection of VOCs by microwave transduction using dealuminated faujasite DAY zeolites as gas sensitive materials [J].
de Fonseca, B. ;
Rossignol, J. ;
Bezverkhyy, I. ;
Bellat, J. P. ;
Stuerga, D. ;
Pribetich, P. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 :558-565
[9]   Sound-resonance hydrogen sensor [J].
Dong, SX ;
Bai, FM ;
Li, JF ;
Viehland, D .
APPLIED PHYSICS LETTERS, 2003, 82 (25) :4590-4592
[10]   Hydrogen Gas Sensors Based on Semiconductor Oxide Nanostructures [J].
Gu, Haoshuang ;
Wang, Zhao ;
Hu, Yongming .
SENSORS, 2012, 12 (05) :5517-5550