Wear predictions for UHMWPE material with various surface properties used on the femoral component in total knee arthroplasty: a computational simulation study

被引:25
作者
Kang, Kyoung-Tak [1 ]
Son, Juhyun [1 ]
Kim, Ho-Joong [2 ,3 ,4 ]
Baek, Changhyun [5 ]
Kwon, Oh-Ryong [6 ]
Koh, Yong-Gon [6 ]
机构
[1] Yonsei Univ, Dept Mech Engn, 50 Yonsei Ro, Seoul 03722, South Korea
[2] Seoul Natl Univ, Coll Med, Spine Ctr, 82 Gumi Ro 173 Beon Gil, Seongnam Si 13620, Gyeonggi Do, South Korea
[3] Seoul Natl Univ, Coll Med, Dept Orthopaed Surg, 82 Gumi Ro 173 Beon Gil, Seongnam Si 13620, Gyeonggi Do, South Korea
[4] Seoul Natl Univ, Bundang Hosp, 82 Gumi Ro 173 Beon Gil, Seongnam Si 13620, Gyeonggi Do, South Korea
[5] Cyber Univ Korea, Dept Mech & Control Engn, 106 Bukchon Ro, Seoul 03051, South Korea
[6] Yonsei Sarang Hosp, Dept Orthopaed Surg, Joint Reconstruct Ctr, 10 Hyoryeong Ro, Seoul 06698, South Korea
关键词
MOLECULAR-WEIGHT POLYETHYLENE; FINITE-ELEMENT-ANALYSIS; IN-VITRO WEAR; REPLACEMENT WEAR; HIP SIMULATOR; KINEMATICS; PROSTHESES; COATINGS; BEHAVIOR; MACHINE;
D O I
10.1007/s10856-017-5916-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The wear of ultrahigh-molecular weight polyethylene (UHMWPE) tibial inserts in total knee arthroplasty (TKA) remains a major limitation that hinders the longevity of clinically successful devices. Surface properties significantly affect the overall performance of TKA, and surface modification with mechanically and chemically stable materials is an effective method for overcoming the wear of TKA. However, wear tests are not cost-efficient or time-efficient; thus, the effects of geometric, loading, and alignment perturbations are often evaluated via parametric studies. Computational wear prediction using a finite element (FE) model followed by validation through comparison with experimental data is effective for assessing new prosthetic designs or surface change methods prior to functional testing and surgical implementation. The aim of this study was to evaluate the weight loss, wear depth, and kinematics for different surface properties, including nanostructured diamond (NSD), diamond-like carbon (DLC), titanium-nitride (TiN), and oxidized zirconium (OxZr) on femoral components in TKA using FE analysis under gait-cycle loading conditions. Weight loss and wear depth were lowest with OxZr followed by TiN, NSD, and DLC. However, the DLC femoral component did not show any improvement in wear rate compared to an uncoated cobalt-chromium (Co-Cr) femoral component. Not all surface changes applied in this study did lead to improvement in wear performance. However, this study demonstrates the potential of OxZr and TiN for reducing UHMWPE wear and offers new insights into the effects of wear on TKA.
引用
收藏
页数:10
相关论文
共 37 条
[1]   Computational wear prediction of artificial knee joints based on a new wear law and formulation [J].
Abdelgaied, Abdellatif ;
Liu, Feng ;
Brockett, Claire ;
Jennings, Louise ;
Fisher, John ;
Jin, Zhongmin .
JOURNAL OF BIOMECHANICS, 2011, 44 (06) :1108-1116
[2]  
AMSTUTZ HC, 1992, CLIN ORTHOP RELAT R, P7
[3]  
[Anonymous], 2002, 142431 ISO
[4]   CONTACT AND RUBBING OF FLAT SURFACES [J].
ARCHARD, JF .
JOURNAL OF APPLIED PHYSICS, 1953, 24 (08) :981-988
[5]   Investigation of wear of knee prostheses in a new displacement/force-controlled simulator [J].
Barnett, PI ;
McEwen, HMJ ;
Auger, DD ;
Stone, MH ;
Ingham, E ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) :51-61
[6]   Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics [J].
Benson, LC ;
DesJardins, JD ;
LaBerge, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :496-504
[7]   Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator [J].
Benson, LC ;
DesJardins, JD ;
Harman, MK ;
LaBerge, M .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) :409-418
[8]   Hip simulator study of the influence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions [J].
Bowsher, JG ;
Shelton, JC .
WEAR, 2001, 250 :167-179
[9]   Wear behavior of UHMWPE sliding on artificial hip arthroplasty materials [J].
Cho, HJ ;
Wei, WJ ;
Kao, HC ;
Cheng, CK .
MATERIALS CHEMISTRY AND PHYSICS, 2004, 88 (01) :9-16
[10]   UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation [J].
DesJardins, John D. ;
Burnikel, Brian ;
LaBerge, Martine .
WEAR, 2008, 264 (3-4) :245-256