In vitro optical quality comparison of 2 trifocal intraocular lenses and 1 progressive multifocal intraocular lens

被引:29
作者
Dominguez-Vicent, Alberto [1 ]
Juan Esteve-Taboada, Jose [1 ]
Del Aguila-Carrasco, Antonio J. [1 ]
Monsalvez-Romin, Daniel [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Optometry Res Grp, Dept Opt & Optometry & Sci Vis, Valencia, Spain
关键词
MODULATION TRANSFER-FUNCTION; BILATERAL IMPLANTATION; PUPIL SIZE; CLINICAL-OUTCOMES; CATARACT-SURGERY; DIFFRACTIVE IOL; VISUAL OUTCOMES; IMAGE QUALITY; PERFORMANCE; DECENTRATION;
D O I
10.1016/j.jcrs.2015.06.040
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the optical quality of 3 multifocal intraocular lenses (IOLs): the Mini Well Ready progressive multifocal aspheric IOL, the AT LISA trifocal diffractive IOL, and the Fine-vision full diffractive trifocal IOL. SETTING: University of Valencia, Valencia, Spain. DESIGN: Experimental study. METHODS: An instrument designed for measuring real-time modulation transfer function (MTF) and IOL power was used to measure the optical quality of each IOL for 3.0 mm and 4.5 mm apertures. This instrument measures both sagittal and tangential MTFs. The optical quality of each IOL was evaluated with the MTF, through-focus MTF, defocus tolerance, Strehl ratio MTF, and relative percentage of light in each focus. These metrics were evaluated at best focus for each IOL. RESULTS: Through-focus graphs corresponding to trifocal IOLs showed 3 mean peaks. Nevertheless, the progressive multifocal aspheric IOL showed 2 main areas, 1 corresponding to distance vision focus and the other including both intermediate and near vision foci. CONCLUSIONS: The results obtained in the present study suggest that the progressive multifocal aspheric IOL might be considered for cataract surgery.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 41 条
[11]   Quality-of-life improvements in cataract patients with bilateral blue light-filtering intraocular lenses: Clinical trial [J].
Espindle, D ;
Crawford, B ;
Maxwell, A ;
Rajagopalan, K ;
Barnes, R ;
Harris, B ;
Hileman, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (10) :1952-1959
[12]   Correlation between optics quality of multifocal intraocular lenses and visual acuity Tolerance to modulation transfer function decay [J].
Felipe, Adelina ;
Pastor, Francisco ;
Artigas, Jose M. ;
Diez-Ajenjo, Amparo ;
Gene, Andres ;
Menezo, Jose L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :557-562
[13]   Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench [J].
Gatinel, Damien ;
Houbrechts, Yvette .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07) :1093-1099
[14]   Design and qualification of a diffractive trifocal optical profile for intraocular lenses [J].
Gatinel, Damien ;
Pagnoulle, Christophe ;
Houbrechts, Yvette ;
Gobin, Laure .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) :2060-2067
[15]  
International Organization for Standardization, 2006, 119799 ISO
[16]  
International Organization for Standardization, 2014, 119792 ISO
[17]   Cataract extraction with multifocal intraocular lens implantation - A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes [J].
Javitt, JC ;
Steinert, RF .
OPHTHALMOLOGY, 2000, 107 (11) :2040-+
[18]   KINOFORM LENSES [J].
JORDAN, JA ;
HIRSCH, PM ;
LESEM, LB ;
VANROOY, DL .
APPLIED OPTICS, 1970, 9 (08) :1883-&
[19]   Modulation transfer function and pupil size in multifocal and monofocal intraocular lenses in vitro [J].
Kawamorita, T ;
Uozato, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (12) :2379-2385
[20]  
KOCH DD, 1991, OPHTHALMOLOGY, V98, P1030