Design of an x-ray FEL undulator

被引:0
|
作者
Carr, R [1 ]
机构
[1] Stanford Linear Accelerator Ctr, Stanford Synchrotron Radiat Lab, Stanford, CA 94309 USA
来源
TOWARDS X-RAY FREE ELECTRON LASERS: WORKSHOP ON SINGLE PASS, HIGH GAIN FELS STARTING FROM NOISE, AIMING AT COHERENT X-RAYS | 1997年 / 413期
关键词
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An undulator designed to be used far an x-ray free electron laser has to meet a set of stringent requirements. With no optical cavity, an x-ray FEL operates in the single pass Self Amplified Spontaneous Emission (SASE) mode; an electron macropulse is microbunched by an undulator and the radiation it creates. The microbunched pulse emits spontaneous radiation and coherent FEL radiation, whose power may reach saturation in a sufficiently long and perfect undulator. The pulse must have low emittance and high current, and its trajectory in the undulator must keep the radiation and the pulse together with a very high degree of overlap. In this paper we use the case of the Linear Coherent Light Source (LCLS) x-ray free electron laser to illustrate design concepts for long free electron laser undulators. [1,2] The LCLS is intended to create 1.5 Angstrom x-rays using an electron beam with 15 GeV energy, 1.5 pi mm-mrad normalized emittance, 3400 A peak current, and 280 fsec FWHM bunch duration. According to our simulations, this 2 sigma(r) = 65 mm rms diameter beam must overlap its radiation with a walkoff of no more than 5 mu m RMS per 11.7 meter field gain length for efficient gain. The energy spread of the beam is sigma(E) = 0.0002 E-L. This places severe limitations on the magnetic field errors and on mechanical tolerances. In this paper we shall discuss how to meet these requirements.
引用
收藏
页码:143 / 154
页数:12
相关论文
共 50 条
  • [31] Conceptual design of a soft X-ray SASE-FEL source
    Alesini, D
    Bertolucci, S
    Biagini, ME
    Biscari, C
    Boni, R
    Boscolo, M
    Castellano, M
    Clozza, A
    Di Pirro, G
    Drago, A
    Esposito, A
    Ferrario, M
    Fusco, V
    Gallo, A
    Ghigo, A
    Guiducci, S
    Incurvati, M
    Laurelli, P
    Ligi, C
    Marcellini, F
    Migliorati, M
    Milardi, C
    Palumbo, L
    Pellegrino, L
    Preger, M
    Raimondi, P
    Ricci, R
    Sanelli, C
    Sgamma, F
    Spataro, B
    Serio, M
    Stecchi, A
    Stella, A
    Tazzioli, F
    Vaccarezza, C
    Vescovi, M
    Vicario, C
    Zobov, M
    Acerbi, E
    Alessandria, F
    Barni, D
    Bellomo, G
    Birattari, C
    Boscolo, I
    Bosotti, A
    Broggi, F
    Cialdi, S
    De Martinis, C
    Giove, D
    Maroli, C
    X-RAY AND INNER-SHELL PROCESSES, 2003, 652 : 53 - 58
  • [32] Improved Generation of Higher Harmonics and Suppression of the Lowest Harmonics in an X-Ray FEL with a Two-Frequency Undulator
    Zhukovsky, K. V.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2018, 73 (05) : 462 - 469
  • [33] Improved Generation of Higher Harmonics and Suppression of the Lowest Harmonics in an X-Ray FEL with a Two-Frequency Undulator
    K. V. Zhukovsky
    Moscow University Physics Bulletin, 2018, 73 : 462 - 469
  • [34] RAY SCIENCE X-ray FEL shines brightly
    Jamison, Steven
    NATURE PHOTONICS, 2010, 4 (09) : 589 - 591
  • [35] DESIGN CONSIDERATIONS FOR A NEW WEAK-FIELD SOFT-X-RAY UNDULATOR FEL DRIVER FOR PEP
    TATCHYN, R
    CREMER, T
    CSONKA, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2): : 152 - 164
  • [36] X-RAY MICROSCOPY WITH THE NSLS SOFT-X-RAY UNDULATOR
    KIRZ, J
    ADE, H
    ANDERSON, E
    ATTWOOD, D
    BUCKLEY, C
    HELLMAN, S
    HOWELLS, M
    JACOBSEN, C
    KERN, D
    LINDAAS, S
    MCNULTY, I
    OVERSLUIZEN, M
    RARBACK, H
    RIVERS, M
    ROTHMAN, S
    SAYRE, D
    SHU, D
    PHYSICA SCRIPTA, 1990, T31 : 12 - 17
  • [37] X-ray focusing test and x-ray imaging test by a microcapillary x-ray lens at an undulator beamline
    Kohmura, Y
    Awaji, M
    Suzuki, Y
    Ishikawa, T
    Dudchik, YI
    Kolchevsky, NN
    Komarov, FF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (11): : 4161 - 4167
  • [38] OBSERVATION OF X-RAY UNDULATOR RADIATION ON PEP
    LAVENDER, W
    BROWN, G
    TROXEL, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1414 - 1418
  • [39] X-RAY UNDULATOR PROGRAM ON PEP.
    Brown, G.S.
    Nuclear instruments and methods in physics research, 1987, A266 (1-3):
  • [40] PERFORMANCE OF A HARD X-RAY UNDULATOR AT CHESS
    BILDERBACK, DH
    BATTERMAN, BW
    BEDZYK, MJ
    FINKELSTEIN, K
    HENDERSON, C
    MERLINI, A
    SCHILDKAMP, W
    SHEN, Q
    WHITE, J
    BLUM, EB
    VICCARO, PJ
    MILLS, DM
    KIM, S
    SHENOY, GK
    ROBINSON, KE
    JAMES, FE
    SLATER, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1419 - 1425