PURPOSE: To determine the accuracy of glaucoma detection by frequency-doubling perimetry. METHODS: Stereoview optic nerve photographs, visual field examination, intraocular pressure measurements, medical and ocular history, and a screening and full threshold frequency-doubling perimetry examination were performed in a prospective study of consecutive subjects, Inclusion criteria included age of 45 years or older, absence of ocular disease other than glaucoma, cataract, or mild drusen, and Snellen visual acuity of 20/60 or better. A total of 125 eyes in 102 glaucoma subjects and 95 eyes of 95 normal subjects were included. Each eye was classified as "normal," "glaucoma," Or "uncertain" by each of three ophthalmologists on the basis of all available clinical information with the exception of frequency-doubling perimetry results. Those in the glaucoma group were subclassified as having early (n = 51), moderate (n = 42), or severe (n = 32) glaucoma on the basis of automated Humphrey visual field criteria. In the glaucoma group, two eyes from a subject were allowed to be included (23 of 102 subjects) if they differed in level of damage because they were never analyzed within the same statistical analysis. RESULTS: Several diagnostic algorithms were evaluated. Algorithms based on the most depressed single point, pair of adjacent points, and cluster of three points performed nearly identically. For the screening test, if any abnormality was identified, specificity was 95%, whereas sensitivity was 39%, 86%, and 100% for early, moderate, and severe glaucoma, respectively. For the full threshold test, with at least one point depressed to the P < 0.5% level, specificity measured 91%, whereas sensitivity was 35%, 88%, and 100% for early, moderate, and severe glaucoma, respectively, The two global indices, mean deviation and pattern standard deviation, were also evaluated and were generally less accurate. CONCLUSION: Frequency-doubling perimetry, which is rapid and easily administered, is effective at detecting moderate and severe disease and appears well suited for glaucoma screening. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:740 / 745
页数:6
相关论文
共 50 条
  • [41] Performance of frequency-doubling technology perimetry in a population-based prevalence survey of glaucoma - The Tajimi study
    Iwase, Aiko
    Tomidokoro, Atsuo
    Araie, Makoto
    Shirato, Shiroaki
    Shimizu, Hiroyuki
    Kitazawa, Yoshiaki
    OPHTHALMOLOGY, 2007, 114 (01) : 27 - 32
  • [42] Performance of glaucoma mass screening with only a visual field test using frequency-doubling technology perimetry
    Iwasaki, A
    Sugita, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (04) : 529 - 537
  • [43] Frequency doubling perimetry in glaucoma early diagnosis
    De Gregorio, F
    Trani, M
    Sedran, L
    Virno, M
    Pannarale, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S69 - S69
  • [44] Influence of test reliability on the screening performance of frequency-doubling perimetry
    Heeg, GP
    Jansonius, NM
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (03) : 585 - 587
  • [45] Learning effect and measurement variability in frequency-doubling technology perimetry in chronic open-angle glaucoma
    Matsuo, H
    Tomita, G
    Suzuki, Y
    Araie, M
    JOURNAL OF GLAUCOMA, 2002, 11 (06) : 467 - 473
  • [46] Cumulative defect (Bebie) curves for frequency-doubling technology perimetry
    Johnson, CA
    Spry, PGD
    PERIMETRY UPDATE 2002/2003, 2004, : 3 - 12
  • [47] Rarebit and frequency-doubling technology perimetry in children and young adults
    Martin, L
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (06): : 670 - 677
  • [48] Screening for glaucomatous visual field loss with frequency-doubling perimetry
    Johnson, CA
    Samuels, SJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (02) : 413 - 425
  • [49] Frequency-doubling threshold Perimetry in predicting glaucoma in a population-based study - The Beijing eye study
    Wang, Ya Xing
    Xu, Liang
    Zhang, Rong Xiu
    Jonas, Jost B.
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (10) : 1402 - 1406
  • [50] Comparing a parallel PERG, automated perimetry, and frequency-doubling thresholds
    Maddess, T
    James, AC
    Goldberg, I
    Wine, S
    Dobinson, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (12) : 3827 - 3832