Distance and near contrast sensitivity function after multifocal intraocular lens implantation

被引:190
作者
Montés-Micó, R
Alió, JL
机构
[1] Univ Miguel Hernandez, Res Dev & Innovat Dept, Inst Oftalmol Alicante, Alicante 03015, Spain
[2] Univ Miguel Hernandez, Sch Med, Alicante 03015, Spain
关键词
D O I
10.1016/S0886-3350(02)01648-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate contrast sensitivity at distance and near after multifocal intraocular lens (IOL) implantation. Setting. Ophthalmologic Institute of Alicante, University Miguel Hernandez, Alicante, Spain. Methods: Contrast sensitivity was measured with the Stereo Optical Functional Acuity Contrast Test at distance and near in 21 patients with a refractive multifocal IOL (Array SA-40N, AMO). A control group with a monofocal IOL (SI-40NB, AMO) was also studied to allow comparison of results. Contrast sensitivity was measured 1, 3, 6, 12, and 18 months after IOL implantation. Results: There was a statistically significant greater reduction in contrast sensitivity at distance at all spatial frequencies in the multifocal group than in the monofocal group during the first month. At 3 months, contrast sensitivity at 12 and 18 cycles per deg remained reduced in the multifocal group; contrast sensitivity at the other frequencies did not differ from that in the monofocal group (P>0.1). At 6, 12, and 18 months, contrast sensitivity at all spatial frequencies was not significantly different between groups (P>0.1). There was a statistically significant greater reduction in near contrast sensitivity in the multifocal group than in the monofocal group at all spatial frequencies during the first and third month after surgery (P<.01). No statistically significant differences were found between groups after 6 months (P>0.1). Contrast sensitivity at distance and near in the multifocal group improved over time (P<.01). Conclusions: The Array IOL provided contrast sensitivity at distance comparable to that obtained with the monofocal IOL between 3 and 6 months after implantation. Near contrast sensitivity improved over time but was always lower than at distance and in the monofocal near-corrected patients, which is acceptable to avoid near visual function degradation.
引用
收藏
页码:703 / 711
页数:9
相关论文
共 28 条
[1]   CONTRAST SENSITIVITY AND READING THROUGH MULTIFOCAL INTRAOCULAR LENSES [J].
AKUTSU, H ;
LEGGE, GE ;
SHOWALTER, M ;
LINDSTROM, RL ;
ZABEL, RW ;
KIRBY, VM .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (08) :1076-1080
[2]   MULTIFOCAL INTRAOCULAR LENSES [J].
DUFFEY, RJ ;
ZABEL, RW ;
LINDSTROM, RL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04) :423-429
[3]   NEW MULTIFOCAL INTRAOCULAR-LENS DESIGN [J].
HANSEN, TE ;
CORYDON, L ;
KRAG, S ;
THIM, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :38-41
[4]   Correlation between pupillary size and intraocular lens decentration and visual acuity of a zonal-progressive multifocal lens and a monofocal lens [J].
Hayashi, K ;
Hayashi, H ;
Nakao, F ;
Hayashi, F .
OPHTHALMOLOGY, 2001, 108 (11) :2011-2017
[5]   OPTICAL-PERFORMANCE OF MULTIFOCAL INTRAOCULAR LENSES [J].
HOLLADAY, JT ;
VANDIJK, H ;
LANG, A ;
PORTNEY, V ;
WILLIS, TR ;
SUN, R ;
OKSMAN, HC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (04) :413-422
[6]   Cataract extraction with multifocal intraocular lens implantation: Clinical, functional, and quality-of-life outcomes - Multicenter clinical trial in Germany and Austria [J].
Javitt, J ;
Brauweiler, HP ;
Jacobi, KW ;
Klemen, U ;
Kohnen, S ;
Quentin, CD ;
Teping, C ;
Pham, T ;
Knorz, MC ;
Poetzsch, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09) :1356-1366
[7]   Cataract extraction with multifocal intraocular lens implantation - A multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes [J].
Javitt, JC ;
Steinert, RF .
OPHTHALMOLOGY, 2000, 107 (11) :2040-+
[8]   CLINICAL-RESULTS OF THE MULTIFOCAL LENS [J].
KEATES, RH ;
PEARCE, JL ;
SCHNEIDER, RT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (05) :557-560
[9]  
Montés-Micó R, 2002, J REFRACT SURG, V18, P9
[10]  
Montés-Micó R, 2001, J REFRACT SURG, V17, P646