A self-adaptive sampling digital image correlation algorithm for accurate displacement measurement

被引:28
作者
Yuan, Yuan [1 ]
Huang, Jianyong [1 ,2 ]
Fang, Jing [1 ]
Yuan, Fan [2 ]
Xiong, Chunyang [1 ]
机构
[1] Peking Univ, Coll Engn, Beijing 100871, Peoples R China
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
基金
中国国家自然科学基金;
关键词
Self-adaptive sampling algorithm; Weighted ZNSSD criterion; Gaussian window; Displacement measurement; Cellular traction force microscopy;
D O I
10.1016/j.optlaseng.2014.05.006
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Digital image correlation (DIC) is nowadays widely applied to many engineering areas as an effective optical displacement measurement technique. To minimize the potential effect of spatial sampling locations on full-field displacement measurement, this paper develops a self-adaptive sampling DIC algorithm for accurate and reliable displacement computation over entire specimen surfaces. Depending on local deformation states, the algorithm can automatically optimize spatial distribution of sampling points over specimen surfaces in a self-adaptive manner in combination with the well-developed DIC algorithm with Gaussian windows. Both a series of well-designed computer-simulated speckle images and actual cell-substrate deformation ones are employed to verify the feasibility and effectiveness of the proposed algorithm, which demonstrates that the set of self-adaptive sampling algorithm is capable of recovering more accurate and precise full-field displacements compared to the conventional DIC algorithm with equidistant sampling. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 20 条
[1]   Full-field 3D measurement using multi-camera digital image correlation system [J].
Chen, Fanxiu ;
Chen, Xu ;
Xie, Xin ;
Feng, Xiu ;
Yang, Lianxiang .
OPTICS AND LASERS IN ENGINEERING, 2013, 51 (09) :1044-1052
[2]   Extended digital image correlation method for micro-region deformation measurement [J].
Chen JinLong ;
Zhang XiaoChuan ;
Zhan Nan .
SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (06) :1355-1361
[3]   Deformation measurement across crack using two-step extended digital image correlation method [J].
Chen, Jinlong ;
Zhang, Xiaochuan ;
Zhan, Nan ;
Hu, Xiaoyan .
OPTICS AND LASERS IN ENGINEERING, 2010, 48 (11) :1126-1131
[4]   Digital image correlation: from displacement measurement to identification of elastic properties - a review [J].
Hild, F ;
Roux, S .
STRAIN, 2006, 42 (02) :69-80
[5]   Evaluation of the quality of a speckle pattern in the digital image correlation method by mean subset fluctuation [J].
Hua, Tao ;
Xie, Huimin ;
Wang, Simon ;
Hu, Zhenxing ;
Chen, Pengwan ;
Zhang, Qingming .
OPTICS AND LASER TECHNOLOGY, 2011, 43 (01) :9-13
[6]   Digital Image Correlation with Self-Adaptive Gaussian Windows [J].
Huang, J. ;
Pan, X. ;
Peng, X. ;
Yuan, Y. ;
Xiong, C. ;
Fang, J. ;
Yuan, F. .
EXPERIMENTAL MECHANICS, 2013, 53 (03) :505-512
[7]   Cellular Traction Force Reconstruction Based on a Self-adaptive Filtering Scheme [J].
Huang, Jianyong ;
Deng, Hao ;
Peng, Xiaoling ;
Li, Shanshan ;
Xiong, Chunyang ;
Fang, Jing .
CELLULAR AND MOLECULAR BIOENGINEERING, 2012, 5 (02) :205-216
[8]   Determination of Cellular Tractions on Elastic Substrate Based on an Integral Boussinesq Solution [J].
Huang, Jianyong ;
Peng, Xiaoling ;
Qin, Lei ;
Zhu, Tao ;
Xiong, Chunyang ;
Zhang, Youyi ;
Fang, Jing .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (06)
[9]   High-temperature digital image correlation method for full-field deformation measurement at 1200 °C [J].
Pan, Bing ;
Wu, Dafang ;
Wang, Zhaoyang ;
Xia, Yong .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (01)
[10]  
Press W. H., 1992, Numerical Recipes in C: The Art of Scientific Computing, V2, DOI DOI 10.2277/052143064X