Diffusion-Weighted Quantitative MRI of Pleural Abnormalities: Intra- and Interobserver Variability in the Apparent Diffusion Coefficient Measurements

被引:10
作者
Priola, Adriano Massimiliano [1 ]
Priola, Sandro Massimo [1 ]
Gned, Dario [1 ]
Giraudo, Teresa [2 ]
Brundu, Maria [1 ]
Righi, Luisella [3 ]
Veltri, Andrea [1 ]
机构
[1] San Luigi Gonzaga Univ Hosp, Dept Diagnost Imaging, Regione Gonzole 10, I-10043 Turin, Italy
[2] Univ Torino, Dept Math, Giuseppe Peano, Turin, Italy
[3] San Luigi Gonzaga Univ Hosp, Dept Pathol, Turin, Italy
关键词
ADC MEASUREMENTS; LUNG-CANCER; ANTERIOR MEDIASTINUM; MYASTHENIA-GRAVIS; CHEMICAL-SHIFT; TUMOR; REGION; QUANTIFICATION; MESOTHELIOMA; VALUES;
D O I
10.1002/jmri.25633
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess intra- and interobserver variability in the apparent diffusion coefficient (ADC) measurements of pleural abnormalities. Materials and Methods: Diffusion-weighted magnetic resonance imaging was performed in 34 patients to characterize pleural abnormalities, with a 1.5T unit at b values of 0/150/500/800 sec/mm(2). In two sessions held 3 months apart, on perfusion-free ADC maps, two independent readers measured the ADC of pleural abnormalities (two readings for each reader in each case) using different methods of region-of-interest (ROI) positioning. In three methods, freehand ROIs were drawn within tumor boundaries to encompass the entire lesion on one or more axial slices (whole tumor volume [WTV], three slices observer-defined [TSOD], single-slice [SS]), while in two methods one or more ROIs were placed on the more restricted areas (multiple small round ROI [MSR], one small round ROI [OSR]). Measurement variability between readings by each reader (intraobserver repeatability) and between readers in first reading (interobserver repeatability) were assessed using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). Analysis of variance (ANOVA) was performed to compare ADC values between the different methods. The measurement time of each case for all methods in first reading was recorded and compared between methods and readers. Results: All methods demonstrated good (MSR, OSR) and excellent (WTV, TSOD, SS) intra-and interreader agreement, with best and worst repeatability in WTV (lower ICC, 0.977; higher CoV, 3.5%) and OSR (lower ICC, 0.625; higher CoV, 22.8%), respectively. The lower 95% confidence interval of ICC resulted in fair to moderate agreement for OSR (up to 0.379) and in excellent agreement for WTV, TSV, and SS (up to 0.918). ADC values of OSR and MSR were significantly lower compared to other methods (P < 0.001). The OSR and SS required less measurement time (10 and 21/22 sec, respectively) compared to the others (P < 0.0001), while the WTV required the longest measurement time (132/134 sec) (P < 0.0001). Conclusion: ADC measurements of pleural abnormalities are repeatable. The SS method has excellent repeatability, similar to WTV, but requires significantly less measurement time. Thus, its use should be preferred in clinical practice.
引用
收藏
页码:769 / 782
页数:14
相关论文
共 46 条
[31]   Influence of selected b values on ADC quantification in diffusion-weighted MRI. Comment on Punwani et al.: Diffusion-weighted MRI of lymphoma: prognostic utility and implications for PET/MRI? [J].
Priola, Adriano M. ;
Priola, Sandro M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (07) :1108-1109
[32]   Apparent diffusion coefficient measurements in diffusion-weighted magnetic resonance imaging of the anterior mediastinum: inter-observer reproducibility of five different methods of region-of-interest positioning [J].
Priola, Adriano Massimiliano ;
Priola, Sandro Massimo ;
Parlatano, Daniela ;
Gned, Dario ;
Giraudo, Maria Teresa ;
Giardino, Roberto ;
Ferrero, Bruno ;
Ardissone, Francesco ;
Veltri, Andrea .
EUROPEAN RADIOLOGY, 2017, 27 (04) :1386-1394
[33]   Importance of different region-of-interest protocols for the apparent diffusion coefficient measurement of tumors in diffusion-weighted magnetic resonance imaging [J].
Priola, Adriano Massimiliano ;
Veltri, Andrea ;
Priola, Sandro Massimo .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (04)
[34]   Diffusion-weighted quantitative MRI to diagnose benign conditions from malignancies of the anterior mediastinum: Improvement of diagnostic accuracy by comparing perfusion-free to perfusion-sensitive measurements of the apparent diffusion coefficient [J].
Priola, Adriano Massimiliano ;
Priola, Sandro Massimo ;
Gned, Dario ;
Piacibello, Edoardo ;
Sardo, Diego ;
Parvis, Guido ;
Torti, Davide ;
Ardissone, Francesco ;
Veltri, Andrea .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (03) :758-769
[35]   Diffusion-weighted magnetic resonance imaging of thymoma: ability of the Apparent Diffusion Coefficient in predicting the World Health Organization (WHO) classification and the Masaoka-Koga staging system and its prognostic significance on disease-free survival [J].
Priola, Adriano Massimiliano ;
Priola, Sandro Massimo ;
Giraudo, Maria Teresa ;
Gned, Dario ;
Fornari, Alessandro ;
Ferrero, Bruno ;
Ducco, Lorena ;
Veltri, Andrea .
EUROPEAN RADIOLOGY, 2016, 26 (07) :2126-2138
[36]   Chemical shift and diffusion-weighted magnetic resonance imaging of the anterior mediastinum in oncology: Current clinical applications in qualitative and quantitative assessment [J].
Priola, Adriano Massimiliano ;
Gned, Dario ;
Veltri, Andrea ;
Priola, Sandro Massimo .
CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2016, 98 :335-357
[37]   Thymoma of the left thymic lobe with a contralateral small pleural implant successfully detected with diffusion-weighted MRI [J].
Priola, Adriano Massimiliano ;
Priola, Sandro Massimo .
TUMORI, 2015, 101 (01) :E13-E17
[38]   Chemical-Shift and Diffusion-Weighted Magnetic Resonance Imaging of Thymus in Myasthenia Gravis Usefulness of Quantitative Assessment [J].
Priola, Adriano Massimiliano ;
Priola, Sandro Massimo ;
Giraudo, Maria Teresa ;
Gned, Dario ;
Giardino, Roberto ;
Marci, Valerio ;
Errico, Luca ;
Veltri, Andrea .
INVESTIGATIVE RADIOLOGY, 2015, 50 (04) :228-238
[39]   Diagnostic and functional imaging of thymic and mediastinal involvement in lymphoproliferative disorders [J].
Priola, Adriano Massimiliano ;
Galetto, Giorgio ;
Priola, Sandro Massimo .
CLINICAL IMAGING, 2014, 38 (06) :771-784
[40]   Diffusion-weighted MRI of the abdomen: Current value in clinical routine [J].
Schmid-Tannwald, Christine ;
Oto, Aytekin ;
Reiser, Maximilian F. ;
Zech, Christoph J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) :35-47