Buckling resistance of concrete-filled cold-formed steel (CF-CFS) built-up short columns under compression

被引:63
|
作者
Rahnavard, Rohola [1 ]
Craveiro, Helder D. [1 ]
Simoes, Rui A. [1 ]
Laim, Luis [1 ]
Santiago, Aldina [1 ]
机构
[1] Univ Coimbra, Dept Civil Engn, ISISE, Coimbra, Portugal
关键词
Concrete-filled; Cold-formed steel; Built-up section; Composite column; Buckling; HIGH-STRENGTH CONCRETE; TUBULAR SHORT COLUMNS; STUB COLUMNS; SHS OUTER; BEHAVIOR; TUBES; DESIGN; CHS; PERFORMANCE;
D O I
10.1016/j.tws.2021.108638
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The steel-concrete composite columns (SCCC) are widely used in the construction sector. The buckling phenomenon of the steel part (especially thin-walled steel) of the SCCC due to compressive loading is the governing characteristic of these columns. The present paper reports an experimental and numerical study on the compressive behavior of innovative concrete-filled (CF) closed built-up cold-formed steel (CFS) columns to investigate the applicability of EN 1994-1-1 for the prediction of the buckling resistance. Twelve CF-CFS short columns were tested. The finite element (FE) design, test setup, procedure, and results, including the load-carrying capacities, load-deformation, and buckling modes, were fully reported. Additionally, the numerical results and EN 1994-1-1 predictions were compared assessing the validity of the EN 1994-1-1 formulations for the estimation of the contributions of each component. Since the closed built-up cross-sections are composed of Class 4 individual cross-sections, both gross and effective sectional areas were considered to estimate the steel contribution to the overall resistance of the composite columns. Based on the FE results it was observed that using the gross area the EN 1994-1-1 formulation overestimates the steel contribution and underestimates it when the effective area is used. Therefore, a modification was proposed for determining the effective cross-sectional areas of Class 4 closed built-up CFS cross-sections, by considering the overlapping plates, fastener positioning, and the concrete encasement of the individual plate elements resulting in a close agreement between the proposed methodology and experimental results.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Built-up nested cold-formed steel compression members subject to local or distortional buckling
    Vy, Son Tung
    Mahendran, Mahen
    Sivaprakasam, Thananjayan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 182
  • [32] COMPRESSION TESTS OF COLD-FORMED STEEL BUILT-UP CLOSED SECTIONS WITH WEB STIFFENERS
    Zhang, Jia-Hui
    Young, Ben
    STEEL AND ALUMINIUM STRUCTURES, 2016,
  • [33] Numerical investigation and design of lightweight aggregate concrete-filled cold-formed built-up box section (CFBBS) stub columns under axial compression
    Teoh K.B.
    Chua Y.S.
    Pang S.D.
    Kong S.Y.
    Engineering Structures, 2024, 303
  • [34] Lateral Impact Response of Elliptical Hollow and Partially Concrete-Filled Cold-Formed Steel Columns Under Static Axial Compression Load
    Rana, Nayyer Mohammadi
    Ghandi, Elham
    Niari, Shirin Esmaeili
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2022, 22 (05)
  • [35] Numerical Analysis of Built-Up Cold-Formed Steel Battened Columns Subjected to Axial Compression
    Huang, Yi
    Zhao, Hongwang
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2025,
  • [36] The mechanics of built-up cold-formed steel members
    Rasmussen, Kim J. R.
    Khezri, Mani
    Schafer, Benjamin W.
    Zhang, Hao
    THIN-WALLED STRUCTURES, 2020, 154 (154)
  • [37] ANALYSIS OF CONCRETE-FILLED UNSTIFFENED AND STIFFENED COLD-FORMED STUB COLUMNS
    Zhu, Ai-Zhu
    Chen, Xian-Chuan
    Zhu, Hong-Ping
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 246 - 252
  • [38] Mechanical Performance of Built-Up Columns Composed of Four Cold-Formed Square Steel Tubes
    Chen, Xiaomiao
    Xia, Junwu
    Xu, Bo
    Ma, Renwei
    APPLIED SCIENCES-BASEL, 2019, 9 (06):
  • [39] Axial compressive behavior of spiral stirrup-reinforced concrete-filled cold-formed steel built-up box stub columns
    Qian, Zhenghao
    Song, Qianyi
    Huang, Haoyuan
    Wang, Weiyong
    ENGINEERING STRUCTURES, 2024, 308
  • [40] Influence of geopolymer foam concrete on the mechanical performance of cold-formed steel built-up columns
    Li, Yanchun
    Wei, Jiahong
    Han, Aihong
    Xu, Yun
    Qiao, Menghui
    He, Dazhi
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2025, 22