Treatment of Femoral Neck Fractures with Cannulated Screw Invasive Internal Fixation Assisted by Orthopaedic Surgery Robot Positioning System

被引:52
|
作者
Wang, Xiao-dong [1 ,2 ]
Lan, Hai [1 ,2 ]
Li, Kai-Nan [2 ]
机构
[1] Zunyi Med Univ, Zunyi, Guizhou, Peoples R China
[2] Chengdu Univ, Affiliated Hosp, Dept Orthopaed, Chengdu 610081, Sichuan, Peoples R China
关键词
Orthopaedic surgery robot positioning system; Femoral neck fractures; Cannulated screw internal fixation; ACCURACY; MANAGEMENT; LUMBAR; YOUNG;
D O I
10.1111/os.12548
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To investigate the clinical efficacy and advantages of cannulated screw internal fixation assisted by the orthopaedic surgery robot positioning system in the treatment of femoral neck fractures. Methods The clinical data of 128 patients with femoral neck fractures which had been treated with cannulated screw internal fixation from January 2016 to July 2018 were retrospectively analyzed. Among them, 63 patients were treated with cannulated screw assisted by orthopedic robot positioning system (orthopaedic surgery robot group), and 65 patients were treated with traditional cannulated screw (traditional surgery group). The operation time, number of intraoperative fluoroscopy, number of guide needle placements, and the amount of operative blood loss were compared between the two groups. The success rate of one-time nail placement and the fracture healing rate were calculated. Fracture healing and internal fixation were observed. The hip joint function was evaluated by the Harris hip score 1 year after operation. Results All patients were followed up for 12 to 24 months. The operation time was 65.70 +/- 9.87 min in the robot group and 73.74 +/- 9.78 min in the traditional group. The number of intraoperative fluoroscopy was 13.67 +/- 4.39 times in the robot group and 17.09 +/- 4.02 times in the traditional group. The number of guide needle placements was 9.95 +/- 3.72 times in the robot group and 13.78 +/- 4.39 times in the traditional surgery group. The success rate of one-time nail placement was 100% (63/63) in the robot group and 49.23% (32/65) in the traditional group. The amount of operative blood loss was 15.25 +/- 6.21 mL in the robot group and 25.51 +/- 6.97 mL in the traditional group. Compared with the traditional group, the robot group had shorter operation time, less fluoroscopy, less needle placement, less bleeding, and higher success rate of one-time nail placement. There was a significant difference between the two groups (P < 0.05). In the robot group, there was no infection, loosening of internal fixation, fracture displacement, and osteonecrosis of femoral head during the follow-up period. The fracture healing rate was 100% (63/63). In the traditional group, there were two cases of loosening of internal fixation and one case of osteonecrosis of femoral head during the follow-up period. The fracture healing rate was 100% (65/65). All patients were evaluated for hip joint function 1 year after operation. The Harris hip score in the robot group was 86.86 +/- 4.74, and the Harris hip score in the traditional surgery group was 83.08 +/- 5.44. Compared with the traditional group, the Harris hip score in the robot group was higher than that in the traditional group. There was significant difference between the two groups (P < 0.05). The excellent and good rate were 92.06% (58/63) in the robot group and 80% (52/65) in the traditional group. There was no significant difference between the two groups (P > 0.05). Conclusion Cannulated screw internal fixation assisted by the orthopaedic surgery robot positioning system is an ideal method for the treatment of femoral neck fractures. This method has the advantages of relatively simple operation, more accurate screw placement during operation, high success rate of one-time nail placement, short operation time, less surgical trauma, less radiation, and good recovery of hip function.
引用
收藏
页码:864 / 872
页数:9
相关论文
共 50 条
  • [1] Application of Robot Positioning for Cannulated Screw Internal Fixation in the Treatment of Femoral Neck Fracture: Retrospective Study
    Wan, Lei
    Zhang, Xiangyun
    Wu, Dalong
    Li, Zhihao
    Yuan, Dongtao
    Li, Junming
    Zhang, Shikui
    Yue, Long
    Zhang, Shao'an
    JMIR MEDICAL INFORMATICS, 2021, 9 (01)
  • [2] Guidance for the Treatment of Femoral Neck Fracture with Precise Minimally Invasive Internal Fixation Based on the Orthopaedic Surgery Robot Positioning System
    Wu, Xin-bao
    Wang, Jun-qiang
    Sun, Xu
    Han, Wei
    ORTHOPAEDIC SURGERY, 2019, 11 (03) : 335 - 340
  • [3] Robot-assisted Percutaneous Cannulated Screw Fixation of Femoral Neck Fractures: Preliminary Clinical Results
    Duan, Sheng-jun
    Liu, Hua-shui
    Wu, Wen-cheng
    Yang, Kun
    Zhang, Zhen
    Liu, Shi-dong
    ORTHOPAEDIC SURGERY, 2019, 11 (01) : 34 - 41
  • [4] Computer-assisted cannulated screw internal fixation versus conventional cannulated screw internal fixation for femoral neck fractures: a systematic review and meta-analysis
    Qing-hao Cheng
    Peng-biao Li
    Ting-ting Lu
    Shi-fang Guo
    Wen-fei Di
    Ke-hu Yang
    Yao-wen Qian
    Journal of Orthopaedic Surgery and Research, 16
  • [5] Computer-assisted cannulated screw internal fixation versus conventional cannulated screw internal fixation for femoral neck fractures: a systematic review and meta-analysis
    Cheng, Qing-Hao
    Li, Peng-Biao
    Lu, Ting-Ting
    Guo, Shi-Fang
    Di, Wen-Fei
    Yang, Ke-Hu
    Qian, Yao-Wen
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [6] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Zhang, Baokun
    Liu, Jingwen
    Zhu, Yi
    Zhang, Wei
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1949 - 1955
  • [7] Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures
    Wang, Jian-Guang
    Wu, Jun-Xian
    Li, Yu-Min
    Xu, You-Yin
    MEDICINE, 2021, 100 (08) : E24834
  • [8] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Baokun Zhang
    Jingwen Liu
    Yi Zhu
    Wei Zhang
    International Orthopaedics, 2018, 42 : 1949 - 1955
  • [9] Intramedullary nails with cannulated screw fixation for the treatment of unstable femoral neck fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Bing
    Jin, Lin
    Lin, Zhe
    Hou, Zhiyong
    Zhang, Yingze
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) : 557 - 568
  • [10] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975