Frequency control of smart base isolation system employing a novel adaptive magneto-rheological elastomer base isolator

被引:18
作者
Gu, Xiaoyu [1 ]
Li, Jianchun [1 ]
Li, Yancheng [1 ]
Askari, Mohsen [1 ]
机构
[1] Univ Technol Sydney, Fac Engn & Informat Technol, Ctr Built Infrastruct Res, Sydney, NSW 2007, Australia
关键词
Magneto-rheological elastomer; adaptive base isolator; modelling; frequency control; five-storey benchmark model; OF-THE-ART;
D O I
10.1177/1045389X15595291
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the past decades, base isolation techniques have become increasingly popular for seismic protection of civil structures owing to its capability of decoupling buildings from harmful ground motion. However, it has been recognised recently that the traditional passive base isolation technique could encounter a serious problem during earthquakes due its incapability in adjusting the isolation frequency to cope with the unpredictability and diversity of earthquakes. To address this challenge, a great deal of research efforts have been conducted to improve traditional base isolation systems, most of which focused on hybrid supplementary devices (passive, active and semi-active types) for the isolators to control displacement or to dissipate seismic energy. On the other hand, the most effective approach to address the aforementioned challenge should lay on varying isolator stiffness in real-time to achieve real-time spontaneous decoupling. A recent advance of the development of an adaptive magneto-rheological elastomer base isolator has brought such idea to reality as the new magneto-rheological elastomer base isolator is capable to alter its stiffness significantly in real-time. In this article, an innovative smart base isolation system employing such magneto-rheological elastomer isolator is proposed and a novel frequency control algorithm is developed to shift the fundamental frequency of the structure away from the dominant frequency range of earthquakes. Such design enables the building to avoid resonant state in real-time according to the on-coming spectrum of the earthquakes. Extensive simulation has been conducted using a five-storey benchmark model with the isolation system, and testing results indicate that the proposed control system is able to significantly suppress both the floor accelerations and inter-storey drifts simultaneously under different earthquakes.
引用
收藏
页码:849 / 858
页数:10
相关论文
共 16 条
[1]  
Djajakesukma SL, 2000, P 5 INT C MOT VIBR C, V2, P569
[2]   SEISMIC BEHAVIOR OF BASE-ISOLATED BUILDINGS - A STATE-OF-THE-ART REVIEW [J].
JANGID, RS ;
DATTA, TK .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1995, 110 (02) :186-203
[3]  
Kelly J.M., 1999, PROC 2 WORLD C STRUC, V1, P1043
[4]   SEISMIC RESPONSE CONTROLLED STRUCTURE WITH ACTIVE VARIABLE STIFFNESS SYSTEM [J].
KOBORI, T ;
TAKAHASHI, M ;
NASU, T ;
NIWA, N ;
OGASAWARA, K .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1993, 22 (11) :925-941
[5]   Finite Element Analysis Of the Temperature Effect Of the Wall Fill Frame Structure [J].
Li Yan ;
Dong Wen-yang ;
Wang Bo .
2013 THIRD INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEM DESIGN AND ENGINEERING APPLICATIONS (ISDEA), 2013, :763-765
[6]   A Highly Adjustable Base Isolator Utilizing Magnetorheological Elastomer: Experimental Testing and Modeling [J].
Li, Yancheng ;
Li, Jianchun .
JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2015, 137 (01)
[7]   A highly adjustable magnetorheological elastomer base isolator for applications of real-time adaptive control [J].
Li, Yancheng ;
Li, Jianchun ;
Tian, Tongfei ;
Li, Weihua .
SMART MATERIALS AND STRUCTURES, 2013, 22 (09)
[8]   Development and characterization of a magnetorheological elastomer based adaptive seismic isolator [J].
Li, Yancheng ;
Li, Jianchun ;
Li, Weihua ;
Samali, Bijan .
SMART MATERIALS AND STRUCTURES, 2013, 22 (03)
[9]   Effects of near-fault ground motions on the nonlinear dynamic response of base-isolated r.c. framed buildings [J].
Mazza, Fabio ;
Vulcano, Alfonso .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (02) :211-232
[10]   Smart base isolation systems [J].
Ramallo, JC ;
Johnson, EA ;
Spencer, BF .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 2002, 128 (10) :1088-1099