Fluorescent Dye Labeling of Erythrocytes and Leukocytes for Studying the Flow Dynamics in Mouse Retinal Circulation

被引:8
作者
Agrawal, Rupesh [1 ,2 ,3 ]
Balne, Praveen Kumar [2 ]
Tun, Sai Bo Bo [2 ]
Wey, Yeo Sia [2 ]
Khandelwal, Neha [1 ]
Barathi, Veluchamy A. [2 ,4 ,5 ]
机构
[1] Tan Tock Seng Hosp, Natl Healthcare Grp Eye Inst, Singapore, Singapore
[2] Singapore Natl Eye Ctr, SERI, Singapore, Singapore
[3] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore, Singapore
[4] Natl Univ Singapore, Natl Univ Hlth Syst, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore, Singapore
[5] DUKE NUS Grad Med Sch, Ophthalmol Acad Clin Res Program, Singapore, Singapore
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2017年 / 125期
基金
英国医学研究理事会;
关键词
Medicine; Issue; 125; Indocyanine green; sodium fluorescein; erythrocytes; leukocytes; blood flow dynamics; fluorescently labeled blood cells; SCANNING LASER OPHTHALMOSCOPE; OPTICAL COHERENCE TOMOGRAPHY; BLOOD-FLOW; IN-VIVO; LYMPHOCYTE MIGRATION; RHODAMINE ISOTHIOCYANATE; CHOROIDAL CIRCULATION; POTENTIAL APPLICATION; DIABETIC-RETINOPATHY; CELLULAR FUNCTION;
D O I
10.3791/55495
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The retinal and choroidal blood flow dynamics may provide insight into the pathophysiology and sequelae of various ocular diseases, such as glaucoma, diabetic retinopathy, age-related macular degeneration (AMD) and other ocular inflammatory conditions. It may also help to monitor the therapeutic responses in the eye. The proper labeling of the blood cells, coupled with live-cell imaging of the labeled cells, allows for the investigation of the flow dynamics in the retinal and choroidal circulation. Here, we describe the standardized protocols of 1.5% indocyanine green (ICG) and 1% sodium fluorescein labeling of mice erythrocytes and leukocytes, respectively. Scanning laser ophthalmoscopy (SLO) was applied to visualize the labeled cells in the retinal circulation of C57BL/6J mice (wild type). Both methods demonstrated distinct fluorescently labeled cells in the mouse retinal circulation. These labeling methods can have wider applications in various ocular disease models.
引用
收藏
页数:9
相关论文
共 47 条
[1]   In vivo labeling of neutrophils using a fluorescent cell linker [J].
Albertine, KH ;
Gee, MH .
JOURNAL OF LEUKOCYTE BIOLOGY, 1996, 59 (05) :631-638
[2]   Mechanisms of Disease Diabetic Retinopathy [J].
Antonetti, David A. ;
Klein, Ronald ;
Gardner, Thomas W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (13) :1227-1239
[3]   Evaluation of Stability and Sensitivity of Cell Fluorescent Labels When Used for Cell Migration [J].
Beem, Elaine ;
Segal, Mark S. .
JOURNAL OF FLUORESCENCE, 2013, 23 (05) :975-987
[4]   INTRACELLULAR FLUORESCENT LABELING OF CELLS FOR ANALYSIS OF LYMPHOCYTE MIGRATION [J].
BRENAN, M ;
PARISH, CR .
JOURNAL OF IMMUNOLOGICAL METHODS, 1984, 74 (01) :31-38
[5]   DIRECT FLUORESCENT LABELING OF CELLS WITH FLUORESCEIN OR RHODAMINE ISOTHIOCYANATE .2. POTENTIAL APPLICATION TO STUDIES OF LYMPHOCYTE MIGRATION AND MATURATION [J].
BUTCHER, EC ;
SCOLLAY, RG ;
WEISSMAN, IL .
JOURNAL OF IMMUNOLOGICAL METHODS, 1980, 37 (02) :109-121
[6]   DIRECT FLUORESCENT LABELING OF CELLS WITH FLUORESCEIN OR RHODAMINE ISOTHIOCYANATE .1. TECHNICAL ASPECTS [J].
BUTCHER, EC ;
WEISSMAN, IL .
JOURNAL OF IMMUNOLOGICAL METHODS, 1980, 37 (02) :97-108
[7]  
Chiba K, 1998, J IMMUNOL, V160, P5037
[8]   Vascular endothelial growth factor and severity of nonproliferative diabetic retinopathy mediate retinal hemodynamics in vivo: A potential role for vascular endothelial growth factor in the progression of nonproliferative diabetic retinopathy [J].
Clermont, AC ;
Aiello, LP ;
Mori, F ;
Aiello, LM ;
Bursell, SE .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (04) :433-446
[9]   USE OF FLUORESCENT DYES IN THE DETERMINATION OF ADHERENCE OF HUMAN-LEUKOCYTES TO ENDOTHELIAL-CELLS AND THE EFFECT OF FLUOROCHROMES ON CELLULAR FUNCTION [J].
DECLERCK, LS ;
BRIDTS, CH ;
MERTENS, AM ;
MOENS, MM ;
STEVENS, WJ .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 172 (01) :115-124
[10]   STUDY OF LYMPHOCYTE DYNAMICS IN THE OCULAR CIRCULATION - TECHNIQUE OF LABELING CELLS [J].
FILLACIER, K ;
PEYMAN, GA ;
LUO, Q ;
KHOOBEHI, B .
CURRENT EYE RESEARCH, 1995, 14 (07) :579-584