An ENS-Oriented Voltage Protection Scheme for Inverter-Based Generators in Active Distribution Networks

被引:22
作者
Ebrahimi, Hossein [1 ]
Yazdaninejadi, Amin [2 ]
Golshannavaz, Sajjad [3 ]
Teimourzadeh, Saeed [4 ]
机构
[1] Urmia Univ, Elect & Comp Engn Dept, Orumiyeh 5717944514, Iran
[2] Shahid Rajaee Teacher Training Univ, Sch Elect & Comp Engn, Tehran 1678815811, Iran
[3] Urmia Univ, Sch Elect & Comp Engn, Orumiyeh 5717944514, Iran
[4] EPRA Elect Energy Co, Res & Dev Dept, TR-06800 Ankara, Turkey
关键词
Relays; Voltage; Resistance; Indexes; Numerical models; Fault currents; Distributed power generation; Directional over-current relay; energy-not-supplied; relays' coordination; voltage index; voltage protection; DIRECTIONAL OVERCURRENT RELAYS; OPTIMAL COORDINATION; DISTRIBUTION-SYSTEMS; REQUIREMENTS;
D O I
10.1109/TSG.2022.3165388
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper unveils that maintaining a proper voltage protection for inverter-based distributed generations (IBDGs) using overcurrent relays and during the power grids' faults with considerable resistance stands as a complicated issue. To overcome this challenge, this paper presents a new protection scheme through developing a voltage index (VI) and launching a new characteristic that concentrates on minimizing energy-not-supplied (ENS). If the developed voltage index is in place, the near area faults with considerable resistance could be effectively discriminated from those at a far distance. Moreover, the adopted characteristic represents two operation modes known by fast and slow modes. For the faults in the vicinity of the IBDG, independent from resistances, the fast part of the proposed characteristic and VI are jointly corresponded to clear the faults swiftly. Moreover, to satisfy coordination time interval (CTI) among relays pairs, the slow part acts in the conventional manner which is corresponded during the backup process. To evaluate the performance of the proposed method, numerical studies are carried out on IEEE 33-bus test system. Results show that the ENS index is enhanced while meeting IBDGs' voltage protection requirements and satisfying selectivity tasks.
引用
收藏
页码:2639 / 2649
页数:11
相关论文
共 38 条
[1]   Optimal Coordination of Directional Overcurrent Relays in Meshed Active Distribution Network Using Imperialistic Competition Algorithm [J].
Alaee, Pegah ;
Amraee, Turaj .
JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (02) :416-422
[2]  
[Anonymous], 2015, MULT 750 760 MAN
[3]  
[Anonymous], 2021, New York Independent System Operator
[4]  
[Anonymous], 2009, document IEC 60255-151
[5]  
[Anonymous], 2014, PROC 12 INT C DEV PO, DOI DOI 10.1049/CP.2014.0146
[6]   Improvement of non-standardized directional overcurrent relay coordination by invasive weed optimization [J].
Castillo, C. A. ;
Conde, A. ;
Shih, M. Y. .
ELECTRIC POWER SYSTEMS RESEARCH, 2018, 157 :48-58
[7]   Optimal Coordination of Directional Overcurrent Relays in Microgrids by Using Cuckoo-Linear Optimization Algorithm and Fault Current Limiter [J].
Dehghanpour, Ehsan ;
Karegar, Hossein Kazemi ;
Kheirollahi, Reza ;
Soleymani, Tohid .
IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (02) :1365-1375
[8]   Flexible Model-Based Alarm Processing for Protection Performance Assessment and Incident Identification [J].
Edwards, Catherine Joyce ;
Davidson, Euan M. ;
McArthur, Stephen D. J. ;
Watt, Ian ;
Cumming, Tom .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (03) :2584-2591
[9]   μPMU-based smart adaptive protection scheme for microgrids [J].
Elbana, Mohamed Salah ;
Abbasy, Nabil ;
Meghed, Ashraf ;
Shaker, Nahil .
JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2019, 7 (04) :887-898
[10]   LINEAR-PROGRAMMING FOR DIRECTIONAL OVERCURRENT RELAY COORDINATION IN INTERCONNECTED POWER-SYSTEMS WITH CONSTRAINT RELAXATION [J].
ELRAFIE, HB ;
IRVING, MR .
ELECTRIC POWER SYSTEMS RESEARCH, 1993, 27 (03) :209-216