Dall-Miles plates for periprosthetic femoral fractures - A critical review of 16 cases

被引:60
作者
Tsiridis, E
Haddad, FS
Gie, GA
机构
[1] Royal Devon & Exeter Hosp, Princess Elizabeth Orthopaed Ctr, Dept Trauma & Orthopaed, London, England
[2] UCL Hosp, London, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2003年 / 34卷 / 02期
关键词
TOTAL HIP-ARTHROPLASTY; SHAFT FRACTURES; FEMUR; MANAGEMENT; REVISION; FIXATION; REPLACEMENT; PROSTHESES; CABLE; STEM;
D O I
10.1016/S0020-1383(02)00161-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Fourteen patients with 16 periprosthetic femoral fractures around hip replacement were treated with Dall-Miles plates between June 1996 and February 2000. There were 10 Vancouver B3, three B1 and three type C fractures. In addition to a Dall-Miles plate, two of the fractures (one B3 and one C type) were also stabilised with one strut graft and nine B3 fractures were revised with impaction grafting. Of the three B1 fractures treated with plates, two failed through fracture of the plate. A further two patients with B3 fractures treated with plates also failed with fracture of the plate. Failure of these plates occurred within 6 months of surgery. All non-unions and fixation failures in this series were in cases where the femoral component did not bypass the most distal fracture line by at least two cortical diameters. The Dall-Miles plates and cable system alone is insufficient for the treatment for periprosthetic femoral fractures. It must be supplemented with additional intramedullary or extramedullary fixation. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:107 / 110
页数:4
相关论文
共 29 条
[1]  
Beals R K., 1996, Clin. Orthop. Relat. Res, V327, P238, DOI DOI 10.1097/00003086-199606000-00029
[2]  
BERMAN AT, 1993, ORTHOPEDICS, V16, P833
[3]  
BERRY DJ, 1999, ORTHOPAEDIC KNOWLEDG, P474
[4]   Classification of the hip [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :215-+
[5]  
Cameron H U, 1997, Acta Orthop Belg, V63 Suppl 1, P8
[6]  
CHRISTENSEN CM, 1989, CLIN ORTHOP RELAT R, V248, P177
[7]   FRACTURES OF THE FEMUR IN RELATION TO CEMENTED HIP PROSTHESES [J].
COOKE, PH ;
NEWMAN, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03) :386-389
[8]  
DALL DM, 1991, TECH ORTHOP, V6, P7
[9]   Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :523-528
[10]  
Duncan CP, 1995, AAOS INSTR COURS LEC, V44, P293