Use of a sliding plate rheometer to measure the first normal stress difference at high shear rates

被引:15
|
作者
Xu, Junke
Costeux, Stephane
Dealy, John M.
De Decker, Mark N.
机构
[1] McGill Univ, Dept Chem Engn, Montreal, PQ H3A 2B2, Canada
[2] LLC, Firestone Polymers, Akron, OH 44319 USA
[3] Dow Chem Co USA, Prod R&D, Midland, MI 48674 USA
关键词
first normal stress difference; molten polymers; sliding plate rheometer; wall slip;
D O I
10.1007/s00397-006-0156-5
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The use of a sliding plate rheometer (SPR) to determine the first normal stress difference of molten polymers and elastomers at high shear rates is demonstrated. The simple shear flow in this instrument is not subject to the flow instabilities that limit the use of rotational rheometers to shear rates often below l s(-1). However, issues of secondary flow and wall slip must be addressed to obtain reliable data using an SPR. A highly entangled, monodisperse polybutadiene and a commercial polystyrene were the polymers studied. The inclusion of the polystyrene made it possible to compare data with those obtained by Lodge using a stressmeter, which is an instrument based on the measurement of the hole pressure. The data from the two instruments are in good agreement and are also close to the predictions of an empirical equation of Laun based on the storage and loss moduli.
引用
收藏
页码:815 / 824
页数:10
相关论文
共 50 条
  • [1] Use of a sliding plate rheometer to measure the first normal stress difference at high shear rates
    Junke Xu
    Stéphane Costeux
    John M. Dealy
    Mark N. De Decker
    Rheologica Acta, 2007, 46 : 815 - 824
  • [2] A sliding plate microgap rheometer for the simultaneous measurement of shear stress and first normal stress difference
    Baik, Seung Jae
    Moldenaers, Paula
    Clasen, Christian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [3] Dynamic response of a shear stress transducer in the sliding plate rheometer
    Kolitawong, C
    Giacomin, AJ
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2002, 102 (01) : 71 - 96
  • [4] Frequency response of a shear stress transducer installed in a sliding plate rheometer
    Dealy, JM
    Jeyaseelan, RS
    JOURNAL OF RHEOLOGY, 1998, 42 (04) : 833 - 841
  • [5] A SLIDING PLATE NORMAL THRUST RHEOMETER FOR MOLTEN PLASTICS
    OAKLEY, JG
    GIACOMIN, AJ
    POLYMER ENGINEERING AND SCIENCE, 1994, 34 (07): : 580 - 584
  • [6] Development of a sliding plate rheometer to measure high frequency viscoelastic properties of polymer melts
    Braybrook, Chelsea A.
    Lee, Jennifer A.
    Bates, Philip J.
    Kontopoulou, Marianna
    APPLIED RHEOLOGY, 2007, 17 (06)
  • [7] Evaluating the exit pressure method for measurements of normal stress difference at high shear rates
    Tang, Dahang
    Marchesini, Flavio H.
    Cardon, Ludwig
    D'hooge, Dagmar R.
    JOURNAL OF RHEOLOGY, 2020, 64 (03) : 739 - 750
  • [8] A high pressure sliding plate rheometer for polymer melts
    Koran, F
    Dealy, JM
    JOURNAL OF RHEOLOGY, 1999, 43 (05) : 1279 - 1290
  • [9] PRESSURE DISTRIBUTION IN GAP OF CONE AND PLATE RHEOMETER WITH RESPECT TO SHEAR OF VISCOELASTIC LIQUIDS HAVING HIGH SHEAR RATES
    GLEISSLE, W
    RHEOLOGICA ACTA, 1976, 15 (06) : 305 - 316
  • [10] Determining the true slip of a yield stress material with a sliding plate rheometer
    Christian Clasen
    Rheologica Acta, 2012, 51 : 883 - 890