Fibrinogen and von Willebrand Factor and Susceptibility Vessel Sign on T2*-Weighted Gradient Echo Imaging

被引:1
|
作者
Farghali, Ahmed [1 ]
Hanss, Michel [2 ]
Berthiller, Julien [3 ,4 ,5 ]
Derex, Laurent [1 ]
Mechtouff, Laura [1 ]
Ritzenthaler, Thomas [1 ]
Cho, Tae-Hee [1 ]
Berthezene, Yves [6 ]
Schott, Anne Marie [3 ]
Ffrench, Patrick [2 ]
Nighoghossian, Norbert [1 ]
机构
[1] Hop Pierre Wertheimer Hosp Civils Lyon, CREATIS, Ctr Urgences Cerebrovasc, F-69677 Lyon, France
[2] Hosp Civils, GHE, CBPE, Hematol Lab, Lyon, France
[3] Univ Lyon, Hosp Civils Lyon, Equipe Accueil 4129, Pole Informat Med Evaluat Rech, Lyon, France
[4] CNRS, INSERM, RIPPS, EPICIME,CIC201,UMR 5558, F-75700 Paris, France
[5] Univ Lyon, Hop L Pradel, CHU Lyon, Serv Pharmacol Clin, Lyon, France
[6] Univ Lyon 1, Hosp Civils Lyon, Hop Pierre Wertheimer, CNRS,INSERM,CREATIS,Serv Neuroradiol,UMR 5220,U10, F-69365 Lyon, France
关键词
Haemostasis; Stroke; Imaging;
D O I
10.1159/000365443
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: We investigated the relationship between von Willebrand factor (vWF), fibrin monomers (FM), fibrinogen baseline levels and the presence of susceptibility vessel sign (SVS) on T2*-weighted gradient echo imaging in acute ischemic stroke. Methods: SVS was assessed at admission using T2*-weighted GRE. Plasmatic levels of vWF, FM and fibrinogen were evaluated before the initiation of intravenous thrombolysis. Results: Forty-four patients were enrolled in this study. SVS was noted in 26 patients. Univariate analysis revealed that vWF >160% (p = 0.02) and fibrinogen >4 g/l (p = 0.03) were associated with a significant decrease in the likelihood of SVS. Multivariate analysis confirmed that higher levels of vWF or fibrinogen predicted the absence of SVS. Conclusions: The increased activity of vWF may promote a fibrin-platelet recruitment mainly contributing to the absence of (SVS). (C) 2014 S. Karger AG, Basel
引用
收藏
页码:375 / 377
页数:3
相关论文
共 36 条
  • [21] Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion
    Rodrigo Fernández-Jiménez
    Javier Sánchez-González
    Jaume Aguero
    María del Trigo
    Carlos Galán-Arriola
    Valentin Fuster
    Borja Ibáñez
    Journal of Cardiovascular Magnetic Resonance, 17
  • [22] Combined acquisition of diffusion and T2*-weighted measurements using simultaneous multi-contrast magnetic resonance imaging
    Breutigam, Nora-Josefin
    Guenther, Matthias
    Hoinkiss, Daniel Christopher
    Eickel, Klaus
    Frost, Robert
    Buck, Mareike Alicja
    Porter, David A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (03) : 421 - 440
  • [23] Microhemorrhagic transformation of ischemic lesions on T2*-weighted magnetic resonance imaging after Pipeline embolization device treatment
    Nakae, Ryuta
    Nagaishi, Masaya
    Kawamura, Yosuke
    Tanaka, Yoshihiro
    Hyodo, Akio
    Suzuki, Kensuke
    JOURNAL OF NEUROSURGERY, 2019, 130 (06) : 1997 - 2004
  • [24] Combined acquisition of diffusion and T2*-weighted measurements using simultaneous multi-contrast magnetic resonance imaging
    Nora-Josefin Breutigam
    Matthias Günther
    Daniel Christopher Hoinkiss
    Klaus Eickel
    Robert Frost
    Mareike Alicja Buck
    David A. Porter
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 421 - 440
  • [25] Hemosiderin Detected by T2*-Weighted Magnetic Resonance Imaging in Patients With Unruptured Cerebral Aneurysms: Indication of Previous Bleeding?
    Takada, Shihomi
    Inoue, Takashi
    Niizuma, Kuniyasu
    Shimizu, Hiroaki
    Tominaga, Teiji
    NEUROLOGIA MEDICO-CHIRURGICA, 2011, 51 (04) : 275 - 281
  • [26] T2-Weighted intracranial vessel wall imaging at 7 Tesla using a DANTE-prepared variable flip angle turbo spin echo readout (DANTE-SPACE)
    Viessmann, Olivia
    Li, Linqing
    Benjamin, Philip
    Jezzard, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 655 - 663
  • [27] Reliability in detection of hemorrhage in acute stroke by a new three-dimensional gradient recalled echo susceptibility-weighted imaging technique compared to computed tomography: A retrospective study
    Wycliffe, ND
    Choe, J
    Holshouser, B
    Oyoyo, UE
    Haacke, EM
    Kido, DK
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) : 372 - 377
  • [28] T2-Weighted Whole-Brain Intracranial Vessel Wall Imaging at 3 Tesla With Cerebrospinal Fluid Suppression
    Zhang, Lei
    Zhu, Yanjie
    Qi, Yulong
    Wan, Liwen
    Ren, Lijie
    Zhu, Yi
    Zhang, Na
    Liang, Dong
    Li, Ye
    Zheng, Hairong
    Liu, Xin
    FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [29] Bleeding Risk Analysis in Stroke Imaging before ThromboLysis (BRASIL) -: Pooled analysis of t2*-weighted magnetic resonance imaging data from 570 patients
    Fiehler, Jens
    Albers, Gregory W.
    Boulanger, Jean-Martin
    Derex, Laurent
    Gass, Achim
    Hjort, Niels
    Kim, Jong S.
    Liebeskind, David S.
    Neumann-Haefelin, Tobias
    Pedraza, Salvador
    Rother, Joachim
    Rothwell, Peter
    Rovira, Alex
    Schellinger, Peter D.
    Trenkler, Johannes
    STROKE, 2007, 38 (10) : 2738 - 2744
  • [30] Development of an MRI Phantom for Diffusion-Weighted Imaging with Independent Adjustment of Apparent Diffusion Coefficient Values and T2 Relaxation Times
    Gatidis, Sergios
    Schmidt, Holger
    Martirosian, Petros
    Schwenzer, Nina F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 459 - 463