Modeling and simulation of uniformity effects in Cd1-xZnxTe gamma-ray spectrometers

被引:12
作者
Toney, JE [1 ]
Schlesinger, TE
James, RB
机构
[1] Carnegie Mellon Univ, Dept Phys, Pittsburgh, PA 15213 USA
[2] Carnegie Mellon Univ, Dept Elect & Comp Engn, Pittsburgh, PA 15213 USA
[3] Sandia Natl Labs, Livermore, CA 94550 USA
关键词
cadmium zinc telluride; material nonuniformity; Monte Carlo simulation; radiation detectors;
D O I
10.1109/23.659560
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Monte Carlo simulations of pulse height spectra for Cd1-xZnxTe detectors are used to investigate the effect of variations in alloy composition and carrier drift lengths on energy resolution, The results, which are based on a simple phenomenological model, show that these nonuniformities can have significant detrimental effects on spectrometer performance. For the case of Bridgman-grown material, the orientation of the growth axis relative to the detector axis is shown to be an important consideration, especially for crystals which come from the heel end of a boule, where the composition gradient due to zinc segregation is large, Other effects which we have simulated include growth striations, zinc segregation at grain boundaries, and trapping by inclusions and grain boundaries; each of these effects is detrimental to energy resolution, We conclude that material nonuniformity is a major obstacle to achieving statistically limited energy resolution in cadmium zinc telluride detectors.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 20 条
[1]   Infra-red microscopy of Cd(Zn)Te radiation detectors revealing their internal electric field structure under bias [J].
DeAntonis, P ;
Morton, EJ ;
Podd, FJW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1487-1490
[2]  
HE Z, 1996, P IEEE NUCL SCI S C, P331
[3]  
KNOLL GF, 1996, P MRS S, V302, P317
[4]   Performance of CdZnTe coplanar-grid gamma-ray detectors [J].
Luke, PN ;
Eissler, EE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1481-1486
[5]  
LUKE PN, 1997, P 5 SCI S ROOM TEMP
[6]   The use of pulse processing techniques to improve the performance of Cd1-xZnxTe gamma-ray spectrometers [J].
Lund, JC ;
Olsen, R ;
VanScyoc, JM ;
James, RB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1411-1416
[7]  
MCGREGOR DS, SEMICONDUCTORS ROOM
[8]   EVALUATION OF CDZNTE DETRACTORS FOR SOFT-X-RAY APPLICATIONS [J].
NIEMELA, A ;
SIPILA, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1054-1057
[9]  
PRETTYMAN T, 1997, P 5 SCI S ROOM TEMP
[10]  
SQUILLANTE M, 1995, SEMICONDUCTORS ROOM, P470