Quantification of blood clotting kinetics II: Thromboelastograph analysis and measurement of erythrocyte sedimentation rate using magnetoelastic sensors

被引:18
|
作者
Roy, Somnath C.
Ong, Keat G.
Zeng, Kefeng
Grimes, Craig A. [1 ]
机构
[1] Penn State Univ, Mat Res Inst, Dept Elect Engn, Mat Res Lab 217, University Pk, PA 16802 USA
[2] Michigan Technol Univ, Dept Biomed Engn, Houghton, MI 49931 USA
[3] KMG2 Sensors Corp, State Coll, PA 16803 USA
关键词
thromboelastograph (TEG); erythrocyte sedimentation rate (ESR); blood clotting kinetics; clot; magnetoelastic;
D O I
10.1166/sl.2007.218
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the development of a low cost, versatile diagnostic system capable of simultaneously performing a thromboelastograph (TEG) analysis and measuring the erythrocyte sedimentation rate (ESR) for the detection of hemophilia, von Willebrand disease, polymyalgia rheumatica, temporal arteritis, and anemia. This diagnostic system is based on use of magnetoelastic sensors that, when excited by a magnetic field, resonate thereby generating a secondary magnetic detectable by a remotely located magnetic coil. By measuring changes in the resonance frequency and resonance amplitude of the sensor both liquid viscosity, and mass loading of the sensor, can be accurately determined. This allows the sensor to monitor real-time blood clotting kinetics as well as clot strength, hence perform a thromboelastograph analysis, as well as determine ESR by measuring mass loading of the sensor as associated with particle settling.
引用
收藏
页码:432 / 440
页数:9
相关论文
共 27 条
  • [21] Blood pressure, pulse rate, and rhythm measurement using ionic polymer-metal composites sensors
    Keshavarzi, A
    Shahinpoor, M
    Kim, KJ
    Lantz, JE
    SMART STRUCTURES AND MATERIALS 1999: ELECTROACTIVE POLYMER ACTUATORS AND DEVICES, 1999, 3669 : 369 - 376
  • [22] New Algorithms for compensation of Error Rate in Noninvasive Blood Pressure Measurement System Using Optical Sensors
    Jeong, In cheol
    Ko, Jae il
    Lee, Dong hee
    Hwang, Sung oh
    Yoon, Hyung ro
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 4123 - +
  • [23] Kinematic and Physiological Analysis of Medieval Combat Sport Using Motion Analysis, Blood Lactate Measurement, and Heart Rate Monitoring: A Case Study
    Mohammadalizadeh, Mojtaba
    Jaiswal, Suraj
    Semken, Scott
    Mikkola, Aki
    SENSORS, 2024, 24 (11)
  • [24] The diagnostic accuracy of blood C-reactive protein and erythrocyte sedimentation rate in periprosthetic joint infections - A 10-year analysis of 1510 revision hip and knee arthroplasties from a single orthopaedic center
    Grzelecki, Dariusz
    Kocon, Maciej
    Mazur, Rafal
    Grajek, Aleksandra
    Kowalczewski, Jacek
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [25] Age induced interactions between heart rate variability and systolic blood pressure variability using approximate entropy and recurrence quantification analysis: a multiscale cross correlation analysis
    Singh, Vikramjit
    Gupta, Amit
    Sohal, J. S.
    Singh, Amritpal
    Bakshi, Surbhi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 497 - 510
  • [26] Age induced interactions between heart rate variability and systolic blood pressure variability using approximate entropy and recurrence quantification analysis: a multiscale cross correlation analysis
    Vikramjit Singh
    Amit Gupta
    J. S. Sohal
    Amritpal Singh
    Surbhi Bakshi
    Physical and Engineering Sciences in Medicine, 2021, 44 : 497 - 510
  • [27] 3D gait analysis in children using wearable sensors: feasibility of predicting joint kinematics and kinetics with personalized machine learning models and inertial measurement units
    Moghadam, Shima Mohammadi
    Auriol, Pablo Ortega
    Yeung, Ted
    Choisne, Julie
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12