Prosthesis-patient mismatch affects survival after aortic valve replacement

被引:1
作者
Rao, V
Jamieson, WRE
Ivanov, J
Armstrong, S
David, TE
机构
[1] Toronto Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
[2] Vancouver Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
关键词
aorta; valves; survival;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "prosthesis-patient" mismatch on long-term survival. Methods and Results-Follow-up was conducted on 2981 patients who underwent AVR with stented bioprostheses between 1976 and 1996. To account for differences between manufacturers' labeled valve sizes, we calculated the ratio between the prosthetic valve effective orifice area (EOA) and the patient's BSA (recorded for 2154 patients). The lowest decile in this cohort had a calculated EOA/BSA of <0.75 cm(2)/m(2) (Small group, n=227) compared with the control group (n=1927), in whom the EOA/BSA ratio was >0.75 cm(2)/m(2). Operative mortality was higher in the Small group (8% versus 5%, P=0.03), Actuarial survival at 12 years was 50+/-5% in the Small group compared with 49+/-2% in the control group (P=0.27). However, freedom from valve-related mortality was significantly lower in the Small group (75+/-5% versus 84+/-2%, P=0.004). Cox regression analysis determined age and NYHA functional class to be the multivariate predictors of overall mortality, whereas advanced age and EOA/BSA <0.75 cm(2)/m(2) were found to be the predictors of valve-related mortality. Conclusions-Prosthesis-patient mismatch results in significantly higher early and late mortality after bioprosthetic AVR. We recommend careful selection of stented bioprostheses to ensure an adequate ratio of EOA to BSA. An EOA/BSA ratio of >0.75 cm(2)/m(2) may avoid residual left ventricular outflow tract obstruction and persistent transvalvular gradients. Careful prosthesis-patient matching will improve both early and late survival after AVR.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [41] Echocardiographic and clinical features of patients developing prosthesis-patient mismatch after transcatheter aortic valve replacement: Insights from the Recovery-TAVR registry
    Bruno, Francesco
    Rampone, Joao Matteo
    Islas, Fabian
    Gorla, Riccardo
    Gallone, Guglielmo
    Melillo, Francesco
    Leone, Pier Pasquale
    Cimaglia, Paolo
    Pastore, Maria Concetta
    Franzone, Anna
    Landra, Federico
    Scudeler, Luca
    Jimenez-Quevedo, Pilar
    Viva, Tommaso
    Piroli, Francesco
    Bragato, Renato
    Trichilo, Michele
    Degiovanni, Anna
    Salizzoni, Stefano
    Ilardi, Federica
    Andreis, Alessandro
    Nombela-Franco, Luis
    Tusa, Maurizio
    Toselli, Marco
    Conrotto, Federico
    Montorfano, Matteo
    Manzo, Rachele
    Cameli, Matteo
    Patti, Giuseppe
    Stefanini, Giulio
    Testa, Luca
    La Torre, Michele
    Giannini, Francesco
    Agricola, Eustachio
    Escaned, Javier
    De Filippo, Ovidio
    De Ferrari, Gaetano M.
    D'Ascenzo, Fabrizio
    AMERICAN HEART JOURNAL, 2024, 275 : 128 - 137
  • [42] Early outcomes of patient-prosthesis mismatch following aortic valve replacement
    Aitaliyev, Serik
    Rumbinaite, Egle
    Melinyte-Ankudavice, Karolina
    Nekrosius, Rokas
    Keturakis, Vytenis
    Benetis, Rimantas
    PERFUSION-UK, 2022, 37 (07): : 692 - 699
  • [43] Moderate patient-prosthesis mismatch can impact on mortality after aortic valve replacement reply
    Mascherbauer, J.
    Baumgartner, H.
    HEART, 2009, 95 (07) : 592 - 593
  • [44] Factors Determining Patient-Prosthesis Mismatch after Aortic Valve Replacement - A Prospective Cohort Study
    Bonderman, Diana
    Graf, Alexandra
    Kammerlander, Andreas A.
    Kocher, Alfred
    Laufer, Guenter
    Lang, Irene M.
    Mascherbauer, Julia
    PLOS ONE, 2013, 8 (12):
  • [45] Impact of Patient-Prosthesis Mismatch on Long-term Outcomes After Aortic Valve Replacement
    Graser, Michaela
    Bleiziffer, Sabine
    Zittermann, Armin
    Mayr, Benedikt
    Sideris, Konstantinos
    Puluca, Nazan
    Krane, Markus
    Prinzing, Anatol
    ANNALS OF THORACIC SURGERY, 2024, 118 (05) : 1063 - 1070
  • [46] Myocardial metabolism and diastolic function after aortic valve replacement for aortic stenosis: influence of patient-prosthesis mismatch
    Mannacio, Vito
    Di Tommaso, Luigi
    Stassano, Paolo
    De Amicis, Vincenzo
    Vosa, Carlo
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (02) : 316 - 321
  • [47] Impact of prosthesis-patient mismatch on long-term survival in patients with small St Jude medical mechanical prostheses in the aortic position
    Mohty-Echahidi, D
    Malouf, JF
    Girard, SE
    Schaff, HV
    Grill, DE
    Enriquez-Sarano, ME
    Miller, FA
    CIRCULATION, 2006, 113 (03) : 420 - 426
  • [48] Is Patient-Prosthesis Mismatch a Perioperative Predictor of Long-Term Mortality After Aortic Valve Replacement?
    Carlos Bianco, Juan
    Qizilbash, Baqir
    Carrier, Michel
    Couture, Pierre
    Fortier, Annik
    Tardif, Jean-Claude
    Lambert, Jean
    Denault, Andre Y.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (04) : 647 - 653
  • [49] Commentary: Prosthesis-Patient Mismatch Increases Early and Late Mortality in Low-Risk Isolated Aortic Valve Replacement: Does it Finally Matter?
    Liakopoulos, Oliver J.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2021, 33 (01) : 33 - 34
  • [50] Prosthesis-Patient Mismatch Predicts Structural Valve Degeneration in Bioprosthetic Heart Valves
    Flameng, Willem
    Herregods, Marie-Christine
    Vercalsteren, Monique
    Herijgers, Paul
    Bogaerts, Kris
    Meuris, Bart
    CIRCULATION, 2010, 121 (19) : 2123 - 2129