Prosthesis-patient mismatch affects survival after aortic valve replacement

被引:1
作者
Rao, V
Jamieson, WRE
Ivanov, J
Armstrong, S
David, TE
机构
[1] Toronto Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
[2] Vancouver Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
关键词
aorta; valves; survival;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "prosthesis-patient" mismatch on long-term survival. Methods and Results-Follow-up was conducted on 2981 patients who underwent AVR with stented bioprostheses between 1976 and 1996. To account for differences between manufacturers' labeled valve sizes, we calculated the ratio between the prosthetic valve effective orifice area (EOA) and the patient's BSA (recorded for 2154 patients). The lowest decile in this cohort had a calculated EOA/BSA of <0.75 cm(2)/m(2) (Small group, n=227) compared with the control group (n=1927), in whom the EOA/BSA ratio was >0.75 cm(2)/m(2). Operative mortality was higher in the Small group (8% versus 5%, P=0.03), Actuarial survival at 12 years was 50+/-5% in the Small group compared with 49+/-2% in the control group (P=0.27). However, freedom from valve-related mortality was significantly lower in the Small group (75+/-5% versus 84+/-2%, P=0.004). Cox regression analysis determined age and NYHA functional class to be the multivariate predictors of overall mortality, whereas advanced age and EOA/BSA <0.75 cm(2)/m(2) were found to be the predictors of valve-related mortality. Conclusions-Prosthesis-patient mismatch results in significantly higher early and late mortality after bioprosthetic AVR. We recommend careful selection of stented bioprostheses to ensure an adequate ratio of EOA to BSA. An EOA/BSA ratio of >0.75 cm(2)/m(2) may avoid residual left ventricular outflow tract obstruction and persistent transvalvular gradients. Careful prosthesis-patient matching will improve both early and late survival after AVR.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [11] Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
    Lee, Seung Hyun
    Chang, Byung Chul
    Youn, Young-Nam
    Joo, Hyun Chel
    Yoo, Kyung-Jong
    Lee, Sak
    JOURNAL OF CARDIOTHORACIC SURGERY, 2017, 12
  • [12] Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement
    Freeman, Melanie
    Webb, John G.
    Willson, Alexander B.
    Wheeler, Miriam
    Blanke, Philipp
    Moss, Robert R.
    Thompson, Christopher R.
    Munt, Brad
    Norgaard, Bjarne L.
    Yang, Tae-Hyun
    Min, James K.
    Poulsen, Steen
    Hansson, Nicolaj C.
    Binder, Ronald K.
    Toggweiler, Stefan
    Hague, Cameron
    Wood, David A.
    Pibarot, Philippe
    Leipsic, Jonathon
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (04) : 248 - 255
  • [13] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Morita, Shigeki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (08) : 435 - 440
  • [14] Association between the Mean Platelet Volume and Prosthesis-patient Mismatch after Transcatheter Aortic Valve Replacement
    Morita, Yuichi
    Ikenaga, Hiroki
    Takeda, Atsushi
    Nakano, Takayuki
    Higashihara, Tasuku
    Watanabe, Noriaki
    Sada, Yoshiharu
    Utsunomiya, Hiroto
    Takahashi, Shinya
    Fukuda, Yukihiro
    Nakano, Yukiko
    INTERNAL MEDICINE, 2024, : 1171 - 1179
  • [15] Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
    Seung Hyun Lee
    Byung Chul Chang
    Young-Nam Youn
    Hyun Chel Joo
    Kyung-Jong Yoo
    Sak Lee
    Journal of Cardiothoracic Surgery, 12
  • [16] Impact of Prosthesis-Patient Mismatch on Long-term Functional Capacity After Mechanical Aortic Valve Replacement
    Petit-Eisenmann, Helene
    Epailly, Eric
    Velten, Michel
    Radojevic, Jelena
    Eisenmann, Bernard
    Kremer, Helene
    Kindo, Michel
    CANADIAN JOURNAL OF CARDIOLOGY, 2016, 32 (12) : 1493 - 1499
  • [17] Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis
    Tasca, G
    Mhagna, Z
    Perotti, S
    Centurini, PB
    Sabatini, T
    Amaducci, A
    Brunelli, F
    Cirillo, M
    Dalla Tomba, M
    Quiani, E
    Troise, G
    Pibarot, P
    CIRCULATION, 2006, 113 (04) : 570 - 576
  • [18] Impact of Prosthesis-Patient Mismatch After Mitral Valve Replacement: A Propensity Score Analysis
    Tsubota, Hideki
    Sakaguchi, Genichi
    Arakaki, Ryoko
    Marui, Akira
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2021, 33 (02) : 347 - 353
  • [19] Prosthesis-Patient Mismatch Causes a Significantly Increased Risk of Operative Mortality in Aortic Valve Replacement
    Shahzeb, Khan Muhammad
    Imran, Bawany Faizan
    Asadullah, Khan
    Mehwish, Hussain
    HEART SURGERY FORUM, 2014, 17 (03) : E127 - E131
  • [20] Impact of Prosthesis-Patient Mismatch on the Regression of Secondary Mitral Regurgitation After Isolated Aortic Valve Replacement With a Bioprosthetic Valve in Patients With Severe Aortic Stenosis
    Angeloni, Emiliano
    Melina, Giovanni
    Pibarot, Philippe
    Benedetto, Umberto
    Refice, Simone
    Ciavarella, Giuseppino M.
    Roscitano, Antonino
    Sinatra, Riccardo
    Pepper, John R.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (01) : 36 - 42