Prosthesis-patient mismatch affects survival after aortic valve replacement

被引:1
作者
Rao, V
Jamieson, WRE
Ivanov, J
Armstrong, S
David, TE
机构
[1] Toronto Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
[2] Vancouver Gen Hosp, Div Cardiovasc Surg, Toronto, ON M5G 2C4, Canada
关键词
aorta; valves; survival;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Surgeons traditionally avoid the use of "small" aortic prostheses because of the potential for residual left ventricular outflow tract obstruction and persistent transvalvular gradients. This study examines the ratio between prosthetic valve size and the body surface area (BSA) of patients undergoing aortic valve replacement (AVR). We sought to determine the effect of potential "prosthesis-patient" mismatch on long-term survival. Methods and Results-Follow-up was conducted on 2981 patients who underwent AVR with stented bioprostheses between 1976 and 1996. To account for differences between manufacturers' labeled valve sizes, we calculated the ratio between the prosthetic valve effective orifice area (EOA) and the patient's BSA (recorded for 2154 patients). The lowest decile in this cohort had a calculated EOA/BSA of <0.75 cm(2)/m(2) (Small group, n=227) compared with the control group (n=1927), in whom the EOA/BSA ratio was >0.75 cm(2)/m(2). Operative mortality was higher in the Small group (8% versus 5%, P=0.03), Actuarial survival at 12 years was 50+/-5% in the Small group compared with 49+/-2% in the control group (P=0.27). However, freedom from valve-related mortality was significantly lower in the Small group (75+/-5% versus 84+/-2%, P=0.004). Cox regression analysis determined age and NYHA functional class to be the multivariate predictors of overall mortality, whereas advanced age and EOA/BSA <0.75 cm(2)/m(2) were found to be the predictors of valve-related mortality. Conclusions-Prosthesis-patient mismatch results in significantly higher early and late mortality after bioprosthetic AVR. We recommend careful selection of stented bioprostheses to ensure an adequate ratio of EOA to BSA. An EOA/BSA ratio of >0.75 cm(2)/m(2) may avoid residual left ventricular outflow tract obstruction and persistent transvalvular gradients. Careful prosthesis-patient matching will improve both early and late survival after AVR.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 50 条
  • [1] Impact of prosthesis-patient mismatch on survival after mitral valve replacement
    Magne, Julien
    Mathieu, Patrick
    Dumesnil, Jean G.
    Tanne, David
    Dagenais, Francois
    Doyle, Daniel
    Pibarot, Philippe
    CIRCULATION, 2007, 115 (11) : 1417 - 1425
  • [2] Prosthesis-patient mismatch after surgical aortic valve replacement in patients with aortic stenosis
    Kim, Hee Jung
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 152 - 157
  • [3] Prosthesis-Patient Mismatch after Aortic Valve Replacement with the Mosaic Ultra Bioprosthesis
    Ntinopoulos, Vasileios
    Biefer, Hector Rodriguez Cetina
    Dushaj, Stak
    Rings, Laura
    Fleckenstein, Philine
    Dzemali, Omer
    Haeussler, Achim
    THORACIC AND CARDIOVASCULAR SURGEON, 2024, 72 (03) : 197 - 204
  • [4] Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis
    Astudillo, Luis M.
    Santana, Orlando
    Urbandt, Pablo A.
    Benjo, Alexandre M.
    Elkayam, Lior U.
    Nascimento, Francisco O.
    Lamas, Gervasio A.
    Lamelas, Joseph
    CLINICS, 2012, 67 (01) : 55 - 60
  • [5] Impact of prosthesis-patient mismatch on mitral regurgitation after aortic valve replacement
    Unger, P.
    Magne, J.
    Eynden, F. Vanden
    Plein, D.
    Van Camp, G.
    Pasquet, A.
    Cosyns, B.
    Dedobbeleer, C.
    Lancellotti, P.
    HEART, 2010, 96 (20) : 1627 - 1632
  • [6] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [7] Reducing Prosthesis-Patient Mismatch With Edwards Magna Prosthesis for Aortic Valve Replacement
    Kume, Yuta
    Fujita, Tomoyuki
    Fukushima, Satsuki
    Hata, Hiroki
    Shimahara, Yusuke
    Matsumoto, Yorihiko
    Yamashita, Kizuku
    Kobayashi, Junjiro
    CIRCULATION JOURNAL, 2017, 81 (04) : 468 - 475
  • [8] Effect of prosthesis-patient mismatch on survival after aortic valve replacement using mechanical prostheses in patients with aortic stenosis
    Tsutsumi K.
    Nagumo M.
    Nishikawa K.
    Takahashi R.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (12) : 577 - 583
  • [9] Impact of prosthesis-patient mismatch on survival after mitral valve replacement: a systematic review
    Zhang Jian-feng
    Wu Yi-cheng
    Shen Wei-feng
    Kong Ye
    CHINESE MEDICAL JOURNAL, 2013, 126 (19) : 3762 - 3766
  • [10] Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    Blais, C
    Dumesnil, JG
    Baillot, R
    Simard, S
    Doyle, D
    Pibarot, P
    CIRCULATION, 2003, 108 (08) : 983 - 988