Evaluation of thermal performance for natural and forced draft wet cooling tower

被引:2
作者
Al-Dulaimi, M. J. [1 ]
Kareem, F. A. [2 ]
Hamad, F. A. [3 ]
机构
[1] Al Esraa Univ Coll, Dept Air Conditioning & Refrigerat Engn Technol, Baghdad, Iraq
[2] Middle Tech Univ, Inst Technol Baghdad, Baghdad, Iraq
[3] Teesside Univ, Engn Sch Sci & Engn, Middlesbrough TS1 3BA, Cleveland, England
关键词
Cooling tower; experimental measurements; natural draft; forced draft; CFD modelling; spray nozzles;
D O I
10.15282/jmes.13.4.2019.19.0475
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents an experimental and numerical investigation of the thermal performance of natural draft wet cooling tower (NDWCT). The experimental investigation is carried out under natural draft condition and forced draft condition created by an axial fan. The operational parameters considered in this study are the thickness of the fill (10 and 20 cm), inlet water temperature (40, 45, and 50 degrees C) and inlet water volume flow rate (5.68, 7.75, and 9.46 L/min). The experimental results showed that the thermal performance is improved when the fans are used with the NDWCT. The temperature difference between inlet and outlet and effectiveness increase by 35% and 37.2%, respectively at fill thickness of 20 cm and water volume flow rate of 11.35 L/min. The temperature distribution of the air and the relative humidity were numerically simulated for both cases of natural and forced draft by employing the commercial CFD software ANSYS Fluent 15. The experimental and numerical results were validated with results from a previous work and showed a good agreement. The experimental results showed that the effectiveness increase by 22% and 30% for NDWCT and FDWCT respectively when in case of fill thickness 20 cm.
引用
收藏
页码:6007 / 6021
页数:15
相关论文
共 18 条
[1]   Investigation of Impingement Heat Transfer for Air-Sand Mixture Flow [J].
Al-Dulaimi, Mustafa J. ;
Rasool, Adnan A. Abdul ;
Hamad, Faik A. .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 94 (01) :134-141
[2]   Experimental investigation on thermal performance of natural draft wet cooling towers employing an innovative wind-creator setup [J].
Alavi, Seyed Rashid ;
Rahmati, Mehdi .
ENERGY CONVERSION AND MANAGEMENT, 2016, 122 :504-514
[3]  
Alok S, 2012, INT J ENG RES, V2, P1050
[4]  
[Anonymous], 2008, ASHRAE HDB HEAT VENT
[5]   Numerical simulation of thermal performance for super large-scale wet cooling tower equipped with an axial fan [J].
Dang, Zhigang ;
Zhang, Zhengqing ;
Gao, Ming ;
He, Suoying .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 :220-234
[6]  
Gudmundsson Y., 2012, THESIS
[7]  
Hamon, 2019, FAN ASS NAT COOL TOW
[8]  
Kareem FA, 2018, INT J ENG TECHNOL, V7, P2575
[9]   3D CFD modeling of natural draft wet-cooling tower with flue gas injection [J].
Klimanek, Adam ;
Cedzich, Michal ;
Bialecki, Ryszard .
APPLIED THERMAL ENGINEERING, 2015, 91 :824-833
[10]   Experimental analysis of heat and mass transfer phenomena in a direct contact evaporative cooling tower [J].
Lemouari, M. ;
Boumaza, M. ;
Kaabi, A. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (06) :1610-1617