Will X-ray Safety Glasses Become Mandatory for Radiological Vascular Interventions?

被引:8
作者
Thomas, Rohit Philip [1 ]
Grau, Mathias [1 ]
Eldergash, Osama [1 ]
Kowald, Tobias [1 ]
Schnabel, Johannes [1 ]
Szczechowicz, Marcin [2 ]
Chavan, Ajay [1 ]
机构
[1] Klinikum Oldenburg AoR, Inst Diagnost & Intervent Radiol, Rahel Straus Str 10, D-26133 Oldenburg, Germany
[2] Klinikum Oldenburg AoR, Univ Hosp, Dept Cardiac Surg, Oldenburg, Germany
关键词
Ocular radiation dose; 2013/59/Euratom; X-ray safety glasses; EYE LENS; OCCUPATIONAL-EXPOSURE; RADIATION-EXPOSURE; MEDICAL STAFF; BRAIN-TUMORS; CARDIOLOGISTS; EXTREMITIES; PROTECTION; DOSIMETRY;
D O I
10.1007/s00270-018-1960-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The annual permissible radiation ocular lens dose has been reduced to 20 millisieverts (mSv) in the current European directive 2013/59/Euratom. The aim of this study was to evaluate the personal radiation dose for vascular interventions with special focus on ocular lens dose. From May 2016 to October 2016, the personal radiation doses of two interventionists and four technicians were prospectively recorded during 206 vascular interventions. The position of personnel, intervention type and fluoroscopy time were recorded. Parameters evaluated were total body dose measured by film dosimeter, hand dose measured by ring thermoluminescent dosimeter (TLD) and ocular lens dose measured by TLD placed in front of the safety glasses. Linear regression analysis was used to estimate the dose at 2 and 5 years. The ocular lens dose, hand and total body dose of the two interventionists were 11/5, 56/47 and 0.6 mSv each, respectively. The estimated 5-year ocular dose was 113.08 mSv (95% CI 38.2-187.97)/40.95 (95% CI 16.9-64.7). Similarly, hand dose was 608.4 mSv (95% CI 442.78-774.38)/514.47 (95% CI 329.83-699.10) and body dose 6.07 mSv (95% CI 4.70-8.22)/5.12 (95% CI 3.65-6.59), respectively. Amongst four technicians, only the first assistant showed recordings of 0.3 mSv body dose, 2 mSv ocular lens dose and 5 mSv hand dose. The yearly ocular lens dose, particularly for interventionists dealing with complex interventions, could cross the permitted yearly limit set by the new Euratom directive. Therefore, X-ray safety glasses would become mandatory for complex radiological vascular interventions. Level III, non-randomized controlled cohort/follow-up study.
引用
收藏
页码:1074 / 1080
页数:7
相关论文
共 26 条
  • [1] Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels
    Antic, V.
    Ciraj-Bjelac, O.
    Rehani, M.
    Aleksandric, S.
    Arandjic, D.
    Ostojic, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 154 (03) : 276 - 284
  • [2] The lens is more sensitive to radiation than we had believed
    Brown, NP
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (04) : 257 - 257
  • [3] Status of eye lens radiation dose monitoring in European hospitals
    Carinou, Eleftheria
    Ginjaume, Merce
    O'Connor, Una
    Kopec, Renata
    Merce, Marta Sans
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (04) : 729 - 739
  • [4] Optimizing Radiation Safety in the Cardiac Catheterization Laboratory: A Practical Approach
    Christopoulos, Georgios
    Makke, Lorenza
    Christakopoulos, Georgios
    Kotsia, Anna
    Rangan, Bavana V.
    Roesle, Michele
    Haagen, Donald
    Kumbhani, Dharam J.
    Chambers, Charles E.
    Kapadia, Samir
    Mahmud, Ehtisham
    Banerjee, Subhash
    Brilakis, Emmanouil S.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (02) : 291 - 301
  • [5] Risk for Radiation-Induced Cataract for Staff in Interventional Cardiology: Is There Reason for Concern?
    Ciraj-Bjelac, Olivera
    Rehani, Madan M.
    Sim, Kui Hian
    Liew, Houng Bang
    Vano, Eliseo
    Kleiman, Norman J.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (06) : 826 - 834
  • [6] Medical progress: Brain tumors
    DeAngelis, LM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (02) : 114 - 123
  • [7] A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology
    Domienik, J.
    Brodecki, M.
    Rusicka, D.
    [J]. RADIATION MEASUREMENTS, 2012, 47 (02) : 130 - 138
  • [8] European Commission, 2013, OFFICIAL J EUROPEAN, V57, P1
  • [9] Summary of the European Directive 2013/59/Euratom: essentials for health professionals in radiology
    European Society of Radiology
    Akata D.
    Adam E.J.
    Damilakis J.
    Ducou le Pointe H.
    Loose R.
    Owens C.
    Frija G.
    Kainberger F.
    Oleaga L.
    Prokop M.
    Vano E.
    Meghzifene A.
    Paulo G.
    Koff D.
    Stiller W.
    Sheppard D.
    [J]. INSIGHTS INTO IMAGING, 2015, 6 (04): : 411 - 417
  • [10] Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
    Haeusler, Uwe
    Czarwinski, Renate
    Brix, Gunnar
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (08) : 2000 - 2008