Nonenhanced Free-Breathing ECG-Gated Steady-State Free Precession 3D MR Angiography of the Renal Arteries: Comparison Between 1.5 T and 3 T

被引:25
|
作者
Lanzman, Rotem Shlomo [1 ]
Kroepil, Patric [1 ]
Schmitt, Peter [2 ]
Freitag, Sonja-Marie [1 ]
Ringelstein, Adrian [1 ]
Wittsack, Hans Joerg [1 ]
Blondin, Dirk [1 ]
机构
[1] Univ Hosp Dusseldorf, Dept Radiol, D-40225 Dusseldorf, Germany
[2] Siemens Healthcare, Imaging & IT Div, Erlangen, Germany
关键词
3T; MR angiography; renal artery; steady-state free precession; DIGITAL-SUBTRACTION-ANGIOGRAPHY; NEPHROGENIC SYSTEMIC FIBROSIS; CONTRAST; EXPERIENCE; SSFP; GADOLINIUM; STENOSIS; HOLD;
D O I
10.2214/AJR.09.2814
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to compare the image quality of free-breathing ECG-gated nonenhanced steady-state free precession (SSFP) MR angiography of renal arteries at 1.5 T and 3 T. SUBJECTS AND METHODS. Twenty volunteers (11 men, nine women; mean age, 23.2 +/- 2.3 years) without a history of renovascular disease participated in the study. Nonenhanced SSFP MR angiography was performed on all subjects at both 1.5 T and 3 T with a maximum interval of 2 weeks between the imaging sessions. The subjective image quality of axial and coronal maximum-intensity-projection reconstructions of four segments (1, abdominal aorta and ostium of renal artery; 2, main renal artery; 3, segmental branches outside renal parenchyma; 4, segmental branches inside renal parenchyma) was evaluated independently by two radiologists using a 4-point scale (4, excellent; 1, nondiagnostic). Relative signal-to-noise ratio, contrast-to-noise ratio, and maximum visible vessel length of the right and left renal arteries also were determined. RESULTS. No significant difference in image quality at 1.5 T and 3 T was found for segments 1 and 2. The mean image quality for segments 3 and 4 was significantly greater at 3 T (3.88 +/- 0.32, 3.17 +/- 0.70) than at 1.5 T (3.32 +/- 0.73, 2.09 +/- 0.81) (p < 0.001). At 3 T, the maximal vessel length of the right (9.85 +/- 0.82 cm) and left (8.3 +/- 0.79 cm) renal arteries was significantly greater than at 1.5 T (8.94 +/- 1.38 cm and 7.58 +/- 1.18 cm, respectively). CONCLUSION. Performing nonenhanced SSFP MR angiography at 3 T significantly improves visualization of peripheral renal arterial segments in healthy subjects as compared to 1.5 T.
引用
收藏
页码:794 / 798
页数:5
相关论文
共 50 条
  • [41] Self-Gated Radial Free-Breathing Liver MR Elastography: Assessment of Technical Performance in Children at 3 T
    Kafali, Sevgi Gokce
    Bolster Jr, Bradley D.
    Shih, Shu-Fu
    Delgado, Timoteo I.
    Deshpande, Vibhas
    Zhong, Xiaodong
    Adamos, Timothy R.
    Ghahremani, Shahnaz
    Calkins, Kara L.
    Wu, Holden H.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (03) : 1271 - 1283
  • [42] 2117 High-resolution 3D free-breathing coronary MR angiography using wideband SSFP at 3 Tesla
    Hsu-Lei Lee
    Ajit Shankaranarayanan
    Gerald M Pohost
    Krishna S Nayak
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [43] Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP): repeatability and comparison of different tagging location
    Yuyang Zhang
    Zhen Xing
    Ying Liu
    Dejun She
    Zheng Zeng
    Dairong Cao
    Abdominal Imaging, 2014, 39 : 1000 - 1008
  • [44] 3D Whole-heart free-breathing qBOOST-T2 mapping
    Milotta, Giorgia
    Ginami, Giulia
    Bustin, Aurelien
    Neji, Radhouene
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1673 - 1687
  • [45] Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP): repeatability and comparison of different tagging location
    Zhang, Yuyang
    Xing, Zhen
    Liu, Ying
    She, Dejun
    Zeng, Zheng
    Cao, Dairong
    ABDOMINAL IMAGING, 2014, 39 (05): : 1000 - 1008
  • [46] Comparison of 3D free-breathing coronary MR angiography and 64-MDCT angiography for detection of coronary stenosis in patients with high calcium scores
    Liu, Xin
    Zhao, Xihai
    Huang, Jie
    Francois, Christopher J.
    Tuite, David
    Bi, Xiaoming
    Li, Debiao
    Carr, James C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) : 1326 - 1332
  • [47] MR angiography of the renal arteries: Intraindividual comparison of double-dose contrast enhancement at 1.5 T with standard dose at 3 T
    Herborn, Christoph U.
    Runge, Val M.
    Watkins, David M.
    Gendron, Jilene M.
    Naul, L. Gill
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) : 173 - 177
  • [48] Evaluation of balanced steady-state free precession (TrueFISP) and K-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla
    Kaul, MG
    Stork, A
    Bansmann, PM
    Nolte-Ernsting, C
    Lund, GK
    Weber, C
    Adam, G
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (11): : 1560 - 1565
  • [49] Optimization of steady-state free precession MRI for lung ventilation imaging with 19F C3F8 at 1.5T and 3T
    Maunder, Adam
    Rao, Madhwesha
    Robb, Fraser
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1130 - 1142
  • [50] Fast isotropic volumetric coronary MR angiography using free-breathing 3D radial balanced FFE acquisition
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Dössell, O
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 197 - 203