The Effect of Crack Width on Chloride-Induced Corrosion of Steel in Concrete

被引:12
作者
Li, Weiwei [1 ]
Liu, Weiqing [1 ]
Wang, Shuguang [1 ]
机构
[1] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211816, Jiangsu, Peoples R China
关键词
REINFORCEMENT CORROSION; PERFORMANCE; EXPOSURE; INITIATION; INGRESS;
D O I
10.1155/2017/3968578
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
When subjected to loading or thermal shrinkage, reinforced concrete structures usually behave in a cracking state, which raises the risk of bar corrosion from the working environment. The influence of cover cracking on chloride-induced corrosion was experimentally investigated through a 654-day laboratory test on cracked reinforced concrete specimens exposed to chloride solution. The concrete specimens have a dimension of 100 mm x 100 mm x 400 mm and a single prefabricated crack at the midspan. When the percentage concentration of chloride ion (0.6%, 1.2%, 2.1%, 3.0%, and 6.0%) and crack width (uncracked, 0.2, 0.3, 0.4, and 0.5 mm) are taken as variables, the experimental results showed that the corrosion rates for cracked specimens increased with increasing percentage concentration of chloride and increasing crack width. This study also showed the interrelationship between crack width and percentage concentration of chloride on the corrosion rate. In addition, an empirical model, incorporating the influence of the cover cracking and chloride concentration, was developed to predict the corrosion rate. This model allows the prediction of the maximum allowable w(cr) based on the given percentage concentration of chloride in the exposure condition.
引用
收藏
页数:11
相关论文
共 19 条
[1]  
ALAMOUDI OSB, 1993, CEMENT CONCRETE RES, V23, P139
[2]   Influence of crack frequency on reinforcement corrosion in concrete [J].
Arya, C ;
OforiDarko, FK .
CEMENT AND CONCRETE RESEARCH, 1996, 26 (03) :345-353
[3]   THE SIMULTANEOUS DETERMINATION OF TAFEL CONSTANTS AND CORROSION RATE - A NEW METHOD [J].
BANDY, R .
CORROSION SCIENCE, 1980, 20 (8-9) :1017-1028
[4]   Experimental study on crack width and crack spacing for Glass-FRP reinforced concrete beams [J].
Barris, C. ;
Torres, L. ;
Vilanova, I. ;
Mias, C. ;
Llorens, M. .
ENGINEERING STRUCTURES, 2017, 131 :231-242
[5]   Influence of service cracking on reinforcement steel corrosion [J].
Francois, R ;
Arliguie, G .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1998, 10 (01) :14-20
[6]  
Gu P, 2000, ACI MATER J, V97, P254
[7]   Estimation of Crack Depth in Concrete Using Diffuse Ultrasound: Validation in Cracked Concrete Beams [J].
In, Chi-Won ;
Arne, Kevin ;
Kim, Jin-Yeon ;
Kurtis, Kimberly E. ;
Jacobs, Laurence J. .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2017, 36 (01)
[8]   The influence of cracks on chloride-induced corrosion of steel in ordinary Portland cement and high performance concretes subjected to different loading conditions [J].
Jaffer, S. J. ;
Hansson, C. M. .
CORROSION SCIENCE, 2008, 50 (12) :3343-3355
[9]   Natural marine exposure results for reinforced concrete slabs with corrosion inhibitors [J].
Kondratova, IL ;
Montes, P ;
Bremner, TW .
CEMENT & CONCRETE COMPOSITES, 2003, 25 (4-5) :483-490
[10]  
Li CQ, 2000, ACI MATER J, V97, P690