pO2 measurements by phosphorescence quenching:: characteristics and applications of an automated system

被引:63
作者
Kerger, H [1 ]
Groth, G
Kalenka, A
Vajkoczy, P
Tsai, AG
Intaglietta, M
机构
[1] Univ Hosp Mannheim, Dept Operat Crit Care Med, Dept Anesthesiol, D-68135 Mannheim, Germany
[2] Univ Hosp Mannheim, Dept Neurosurg, D-68135 Mannheim, Germany
[3] Univ Calif San Diego, Dept Bioengn, La Jolla, CA 92093 USA
关键词
pO(2); measurement microcirculation; phosphorescence quenching;
D O I
10.1016/S0026-2862(02)00027-4
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
An automated system for pO(2) analysis based upon phosphorescence quenching was tested. The system was calibrated in vitro with capillary samples of saline and blood. Results were compared to a conventional measuring procedure wherein pO(2) was calculated off-line by computer fitting of phosphorescence decay signals. PO2 measurements obtained by the automated system were correlated (r(2) = 0.98) with readings simultaneously generated by a blood gas analyzer, accuracy being highest in the low (0-20 mm Hg) and medium pO(2) ranges (21-70 mm He). Measurements in in vivo studies in the hamster skin-fold preparation were similar to previously reported results. The automated system fits the phosphorescence decay data to a single exponential and allows repeated pO(2) measurements in rapid sequence. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 22 条
  • [1] In vivo pO2 measurements in hamster skinfold by recessed pO2 microelectrodes and phosphorescence quenching are in agreement
    Buerk, DG
    Tsai, AG
    Intaglietta, M
    Johnson, PC
    [J]. MICROCIRCULATION, 1998, 5 (2-3) : 219 - 225
  • [2] TECHNICAL REPORT - A NEW CHAMBER TECHNIQUE FOR MICRO-VASCULAR STUDIES IN UNANESTHETIZED HAMSTERS
    ENDRICH, B
    ASAISHI, K
    GOTZ, A
    MESSMER, K
    [J]. RESEARCH IN EXPERIMENTAL MEDICINE, 1980, 177 (02) : 125 - 134
  • [3] Analysis of phosphorescence in heterogeneous systems using distributions of quencher concentration
    Golub, AS
    Popel, AS
    Zheng, L
    Pittman, RN
    [J]. BIOPHYSICAL JOURNAL, 1997, 73 (01) : 452 - 465
  • [4] Phosphorescence quenching method for measurement of intracellular Po2 in isolated skeletal muscle fibers
    Hogan, MC
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) : 720 - 724
  • [5] MICROVASCULAR MEASUREMENTS BY VIDEO IMAGE SHEARING AND SPLITTING
    INTAGLIETTA, M
    TOMPKINS, WR
    [J]. MICROVASCULAR RESEARCH, 1973, 5 (03) : 309 - 312
  • [6] Microvascular oxygen delivery and interstitial oxygenation during sodium pentobarbital anesthesia
    Kerger, H
    Saltzman, DJ
    Gonzales, A
    Tsai, AG
    vanAckern, K
    Winslow, RM
    Intaglietta, M
    [J]. ANESTHESIOLOGY, 1997, 86 (02) : 372 - 386
  • [7] Systemic and microcirculatory effects of autologous whole blood resuscitation in severe hemorrhagic shock
    Kerger, H
    Waschke, KF
    Ackern, KV
    Tsai, AG
    Intaglietta, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (06): : H2035 - H2043
  • [8] SYSTEMIC AND SUBCUTANEOUS MICROVASCULAR OXYGEN-TENSION IN CONSCIOUS SYRIAN GOLDEN-HAMSTERS
    KERGER, H
    TORRES, IP
    RIVAS, M
    WINSLOW, RM
    INTAGLIETTA, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (02): : H802 - H810
  • [9] Depression of endothelial and smooth muscle cell oxygen consumption by endotoxin
    Motterlini, R
    Kerger, H
    Green, CJ
    Winslow, RM
    Intaglietta, M
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 275 (03): : H776 - H782
  • [10] Pawlowski Marek, 1992, V316, P179