Transperineal Ultrasound for Perianal Fistulas and Abscesses - A Systematic Review and Meta-Analysis

被引:27
作者
Maconi, Giovanni [1 ]
Greco, Maria Teresa [2 ]
Asthana, Anil Kumar [3 ]
机构
[1] L Sacco Univ Hosp, Dept Biomed & Clin Sci, Gastroenterol Unit, Via GB Grassi 74, I-20157 Milan, Italy
[2] ATS, Epidemiol Unit, Metropolitan City Of Mil, Italy
[3] Alfred Hosp, Dept Gastroenterol, Melbourne, Vic, Australia
来源
ULTRASCHALL IN DER MEDIZIN | 2017年 / 38卷 / 03期
关键词
anus; fistula; abscess; perianal; ultrasound; meta-analysis; CROHNS-DISEASE; ULTRASONOGRAPHY; SONOGRAPHY; MANAGEMENT; ACCURACY; EXAM;
D O I
10.1055/s-0043-103954
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose Transperineal ultrasound (TPUS) is a practical tool for assessing perianal inflammatory lesions. We systematically review its accuracy for detecting and classifying perianal fistulae and abscesses. Method The National Library of Medicine and Embase were searched for articles on TPUS for the assessment of idiopathic and Crohn's perianal fistulae and abscesses. Two reviewers independently reviewed eligible studies and rated them for quality using the QUADAS tool. The primary outcome measure was the accuracy of TPUS as measured by its sensitivity and positive predictive value (PPV) in detecting and classifying perianal fistulae, internal openings and perianal abscesses. Results We included 12 studies (565 patients). Overall, the methodological quality of the studies was suboptimal. 3 studies were retrospective and 4 showed significant risks of bias in the application of the reference standard. The sensitivity of TPUS in detecting perianal fistulae on a per-lesion basis was 98 % (95 % CI 96 - 100 %) and the PPV was 95 % (95 % CI 90 98 %). The detection of internal openings had a sensitivity of 91 % (95 % CI 84 - 97 %) with a PPV of 87 % (95 % CI 76 95 %). The classification of fistulae yielded a sensitivity of 92 % (95 % CI 85 - 97%) and a PPV of 92% (95% CI 83-98 %). TPUS had a sensitivity of 86 % (95 % CI 67 -99 %) and PPV of 90% (95% CI 76-99 %) in the detection of perianal abscesses. Conclusion The current literature on TPUS illustrates good overall accuracy in the assessment of perianal fistulae and abscesses. However, many studies had methodological flaws suggesting that further research is required.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 25 条
[21]   Transperineal ultrasonography: First level exam in IBD patients with perianal disease [J].
Terracciano, Fulvia ;
Scalisi, Giuseppe ;
Bossa, Fabrizio ;
Scimeca, Daniela ;
Biscaglia, Giuseppe ;
Mangiacotti, Michele ;
Valvano, Maria Rosa ;
Perri, Francesco ;
Simeone, Anna ;
Andriulli, Angelo .
DIGESTIVE AND LIVER DISEASE, 2016, 48 (08) :874-879
[22]   The second European evidence-based Consensus on the diagnosis and management of Crohn's disease: Special situations [J].
Van Assche, Gert ;
Dignass, Axel ;
Reinisch, Walter ;
van der Woude, C. Janneke ;
Sturm, Andreas ;
De Vos, Martine ;
Guslandi, Mario ;
Oldenburg, Bas ;
Dotan, Iris ;
Marteau, Philippe ;
Ardizzone, Alessandro ;
Baumgart, Daniel C. ;
D'Haens, Geert ;
Gionchetti, Paolo ;
Portela, Francisco ;
Vucelic, Boris ;
Soderholm, Johan ;
Escher, Johanna ;
Koletzko, Sibylle ;
Kolho, Kaija-Leena ;
Lukas, Milan ;
Mottet, Christian ;
Tilg, Herbert ;
Vermeire, Severine ;
Carbonnel, Frank ;
Cole, Andrew ;
Novacek, Gottfried ;
Reinshagen, Max ;
Tsianos, Epameinondas ;
Herrlinger, Klaus ;
Oldenburg, Bas ;
Bouhnik, Yoram ;
Kiesslich, Ralf ;
Stange, Eduard ;
Travis, Simon ;
Lindsay, James .
JOURNAL OF CROHNS & COLITIS, 2010, 4 (01) :63-101
[23]  
Wedemeyer J, 2004, WORLD J GASTROENTERO, V10, P2859
[24]   Development and validation of methods for assessing the quality of diagnostic accuracy studies [J].
Whiting, P ;
Rutjes, AWS ;
Dinnes, J ;
Reitsma, JB ;
Bossuyt, PMM ;
Kleijnen, J .
HEALTH TECHNOLOGY ASSESSMENT, 2004, 8 (25) :1-+
[25]   Transperineal versus hydrogen peroxide-enhanced endoanal ultrasonography in never operated and recurrent cryptogenic fistula-in-ano: A pilot study [J].
Zbar A.P. ;
Oyetunji R.O. ;
Gill R. .
Techniques in Coloproctology, 2006, 10 (4) :297-302