Numerical optimization of a novel ceiling radiant cooling panel combined with wall attached ventilation system

被引:24
作者
Ye, Minzhi [1 ]
Serageldin, Ahmed A. [2 ,3 ]
Nagano, Katsunori [2 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Sapporo, Hokkaido 0608628, Japan
[2] Hokkaido Univ, Fac Engn, Div Human Environm Syst, Kita Ku, N13-W8, Sapporo, Hokkaido 0608628, Japan
[3] Benha Univ, Shoubra Fac Engn, Dept Mech Engn, Cairo 11629, Egypt
关键词
Radiant ceiling panel; Wall attached ventilation; Optimization; Response surface; Sensitivity analysis; DISPLACEMENT VENTILATION; THERMAL COMFORT; ENERGY; PERFORMANCE; BUILDINGS; DESIGN;
D O I
10.1016/j.csite.2021.101066
中图分类号
O414.1 [热力学];
学科分类号
摘要
The warm draft that floats from the window has an unfavorable influence on the indoor thermal comfort condition, which heated the indoor air temperature. Therefore, an integrated cooling system combined novel free-suspended ceiling radiant cooling panel (CRCP) with a wall Attached Ventilation (WAV) system is proposed and investigated by using a three-dimensional conjugated computational fluid dynamic (CFD). Two different WAV systems (ceiling inlet/ceiling outlet; ceiling inlet/floor outlet) are examined under various operating conditions. Moreover, the surface response, sensitivity analysis, and optimization of the system's operating condition are carried out via the ANSYS Design Explorer tool. In conclusion, adding the ventilation system with a ceiling inlet and ceiling outlet is more effective than installing a ceiling inlet and a floor outlet. Moreover, the operating conditions with the inlet air velocity of 0.164 m/s, inlet air temperature of 25 degrees C, and panel surface temperature of 23 degrees C are selected as the optimum design. Under this condition, the system can prevent warm draft effectively and achieve better thermal comfort using a lower ventilation flow rate, higher ventilation temperature, and higher panel surface temperatures. Thus, it also shows a significant potential of energy-saving accordingly.
引用
收藏
页数:18
相关论文
共 31 条
[1]   Numerical modeling and optimization of thermal comfort in building: Central composite design and CFD simulation [J].
Alizadeh, M. ;
Sadrameli, S. M. .
ENERGY AND BUILDINGS, 2018, 164 :187-202
[2]  
Ansys Fluent 14, US GUID
[3]   Coaxial personalized ventilation system and window performance for human thermal comfort in asymmetrical environment [J].
Antoun, Sylvie ;
Ghaddar, Nesreen ;
Ghali, Kamel .
ENERGY AND BUILDINGS, 2016, 111 :253-266
[4]   A fresh (air) look at ventilation for COVID-19: Estimating the global energy savings potential of coupling natural ventilation with novel radiant cooling strategies [J].
Aviv, Dorit ;
Chen, Kian Wee ;
Teitelbaum, Eric ;
Sheppard, Denon ;
Pantelic, Jovan ;
Rysanek, Adam ;
Meggers, Forrest .
APPLIED ENERGY, 2021, 292
[5]   Displacement ventilation with radiant panel for hospital wards: Measurement and prediction of the temperature and contaminant concentration profiles [J].
Choi, Narae ;
Yamanaka, Toshio ;
Sagara, Kazunobu ;
Momoi, Yoshihisa ;
Suzuki, Tomoya .
BUILDING AND ENVIRONMENT, 2019, 160
[6]   Numerical comparison between energy and comfort performances of radiant heating and cooling systems versus air systems [J].
Fabrizio, Enrico ;
Corgnati, Stefano P. ;
Causone, Francesco ;
Filippi, Marco .
HVAC&R RESEARCH, 2012, 18 (04) :692-708
[7]  
Geology E, 1963, THEIR MOST GEN ACCEP, V58, P1246
[8]   Thermal comfort and energy consumption of the radiant ceiling panel system. Comparison with the conventional all-air system [J].
Imanari, T ;
Omori, T ;
Bogaki, K .
ENERGY AND BUILDINGS, 1999, 30 (02) :167-175
[9]   Thermal comfort in buildings using radiant vs. all-air systems: A critical literature review [J].
Karmann, Caroline ;
Schiavon, Stefano ;
Bauman, Fred .
BUILDING AND ENVIRONMENT, 2017, 111 :123-131
[10]   Combining suspended radiant ceiling with diffuse ventilation - Numerical performance analysis of low-energy office space in a temperate climate [J].
Krusaa, Marie Rugholm ;
Hviid, Christian Anker .
JOURNAL OF BUILDING ENGINEERING, 2021, 38