Simultaneous measurement of refractive index and temperature using a hybrid-grating sensor

被引:8
作者
Fan, Xiaojun [1 ,2 ,3 ]
Jiang, Junfeng [1 ,2 ,3 ]
Zhang, Xuezhi [1 ,2 ,3 ]
Liu, Kun [1 ,2 ,3 ]
Wan, Shuang [1 ,2 ,3 ]
Liu, Tiegen [1 ,2 ,3 ]
机构
[1] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Inst Opt Fiber Sensing, Tianjin Opt Fiber Sensing Engn Ctr, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Minist Educ, Key Lab Optoelect Informat Technol, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
LONG-PERIOD;
D O I
10.7567/1882-0786/ab4407
中图分类号
O59 [应用物理学];
学科分类号
摘要
A hybrid-grating-based optical fiber sensor for simultaneously measuring the refractive index (RI) and temperature is proposed. The sensor is fabricated by inscribing a long period grating (LPG) and tilted fiber Bragg grating (TFBG) in the same region of an optical fiber in sequence. The hybrid grating takes advantage of both LPG's high temperature sensitivity and TFBG's high RI sensitivity, with consideration of the temperature-insensitive characteristic of wavelength difference between the cladding mode wavelength and core mode wavelength of TFBG. Experiments prove the ability of the sensor to measure the RI and temperature simultaneously. The sensitivities are 606.82 nm/RIU and 268.79 pm degrees C-1, respectively. (C) 2019 The Japan Society of Applied Physics
引用
收藏
页数:6
相关论文
共 25 条
  • [1] Tilted fiber Bragg grating sensors
    Albert, Jacques
    Shao, Li-Yang
    Caucheteur, Christophe
    [J]. LASER & PHOTONICS REVIEWS, 2013, 7 (01) : 83 - 108
  • [2] Simultaneous measurement of temperature and refractive index using focused ion beam milled Fabry-Perot cavities in optical fiber micro-tips
    Andre, Ricardo M.
    Warren-Smith, Stephen C.
    Becker, Martin
    Dellith, Jan
    Rothhardt, Manfred
    Zibaii, M. I.
    Latifi, H.
    Marques, Manuel B.
    Bartelt, Hartmut
    Frazao, Orlando
    [J]. OPTICS EXPRESS, 2016, 24 (13): : 14053 - 14065
  • [3] Choi S., 2004, PHOTON TECHNOL LETT, V17, P115
  • [4] Measurements of refractive index sensitivity using long-period grating refractometer
    Chong, JH
    Shum, P
    Haryono, H
    Yohana, A
    Rao, MK
    Lu, C
    Zhu, YN
    [J]. OPTICS COMMUNICATIONS, 2004, 229 (1-6) : 65 - 69
  • [5] Distributed magnetic field sensor based on magnetostriction using Rayleigh backscaftering spectra shift in optical frequency-domain reflectometry
    Du, Yang
    Lu, Tiegen
    Ding, Zhenyang
    Liu, Kun
    Feng, Bowen
    Jiang, Junfeng
    [J]. Applied Physics Express, 2015, 8 (01)
  • [6] Fan XD, 2011, NAT PHOTONICS, V5, P591, DOI [10.1038/NPHOTON.2011.206, 10.1038/nphoton.2011.206]
  • [7] Hanglin L., 2018, OPT EXPRESS, V26, P18920
  • [8] Self temperature referenced refractive index sensor by non-uniform thinned fiber Bragg gratings
    Iadicicco, A.
    Campopiano, S.
    Cutolo, A.
    Giordano, M.
    Cusano, A.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 120 (01) : 231 - 237
  • [9] Surface plasmon resonance instrument as a refractometer for liquids and ultrathin films
    Liang, Huamin
    Miranto, Heini
    Granqvist, Niko
    Sadowski, Janusz W.
    Viitala, Tapani
    Wang, Bochu
    Yliperttula, Marjo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01) : 212 - 220
  • [10] High-sensitive and temperature-self-calibrated tilted fiber grating biological sensing probe
    Liu Fu
    Guo Tuan
    Liu JianGuo
    Zhu XiaoYang
    Liu Yu
    Guan BaiOu
    Albert, Jacques