A new technique for determining the rotational alignment of the tibial component during total knee arthroplasty

被引:4
|
作者
Kawaguchi, Kohei [1 ]
Inui, Hiroshi [1 ]
Yamagami, Ryota [1 ]
Kenichi, Kono [1 ]
Sameshima, Shin [1 ]
Kage, Tomofumi [1 ]
Taketomi, Shuji [1 ]
Tanaka, Sakae [1 ]
机构
[1] Tokyo Univ Hosp, Dept Orthopaed, Tokyo, Japan
关键词
Tibial component rotation; Range of motion technique; Total knee arthroplasty; Navigation system; Akagi's line; REPLACEMENT; KINEMATICS;
D O I
10.1016/j.knee.2021.02.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We evaluated the effectiveness of our new technique "Range of motion-anatomical (ROM-A) technique" which is the combination of the self-positioning technique "Range of motion (ROM) technique" and the anatomical landmarks technique in determining the tibial component (TC) rotation alignment in total knee arthroplasty (TKA) using a navigation system. Methods: This retrospective study included 103 knees who underwent TKA. The ROM-A technique was consisted of two steps. First, the TC was set and marked by the ROM technique in knee extension. Second, the TC was set according to the marking in the knee flexion and the component rotational angle relative to the anatomical tibial anteroposterior (AP) axis was adjusted between 0 degrees and 10 degrees external rotation using the navigation system. The rotational angle of TC relative to the anatomical AP axis was measured using postoperative computed tomography. Moreover, the hypothetical rotational angle of the TC in the ROM technique was calculated only from the intraoperative difference between the two techniques. Results: The actual rotational angle by the ROM-A technique was externally rotated 3.0 degrees, and the rotational outlier occurred in 3.0%. A significant difference in outlier rate was observed between the two techniques (p = 0.03). The hypothetical rotational angle of TC determined by the ROM technique (the first step only in the ROM-A technique) was externally rotated 4.6 degrees and the TC rotational outlier (difference to AP axis: >10 degrees) occurred in 11.7%. Conclusion: Using the ROM-A technique, the TC was finally fixed in almost all targeted rotational positions, and this technique could reduce the anatomical rotational outlier compared with the ROM technique. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [41] Computer-assisted surgery improves rotational positioning of the femoral component but not the tibial component in total knee arthroplasty
    Hernandez-Vaquero, Daniel
    Noriega-Fernandez, Alfonso
    Manuel Fernandez-Carreira, Jose
    Manuel Fernandez-Simon, Jose
    Llorens de los Rios, Jimena
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3127 - 3134
  • [42] Usefulness of the "grand-piano sign" for determining femoral rotational alignment in total knee arthroplasty
    Ohmori, Takaaki
    Kabata, Tamon
    Kajino, Yoshitomo
    Taga, Tadashi
    Inoue, Daisuke
    Yamamoto, Takashi
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueno, Takuro
    Tsuchiya, Hiroyuki
    KNEE, 2018, 25 (01) : 15 - 24
  • [43] Optimal rotational positioning of tibial component in total knee arthroplasty: determined by linker surgical technique using a high definition CT
    Woon-Hwa Jung
    Jai-Gon Seo
    Dong Hyun Kim
    Suryamanikanta Balabadra
    Utkrisht Mandot
    Dinesh Kumar
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 401 - 408
  • [44] A new landmark for measuring tibial component rotation after total knee arthroplasty
    Mahmood, Fand F.
    Holloway, Nicholas J.
    Deakin, Angela H.
    Clarke, Jon V.
    Picard, Frederic
    KNEE, 2019, 26 (03) : 779 - 786
  • [45] Effect of Tibial Slope on Coronal Alignment in Total Knee Arthroplasty
    Betzle, Christopher J.
    Bringe, Kariline E.
    Horberg, John, V
    Moskal, Joseph T.
    Mann, John W.
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 445 - 449
  • [46] Tibial component rotation in total knee arthroplasty
    Peter Z. Feczko
    Bart G. Pijls
    Michael J. van Steijn
    Lodewijk W. van Rhijn
    Jacobus J. Arts
    Peter J. Emans
    BMC Musculoskeletal Disorders, 17
  • [47] Cementing the Tibial Component in Total Knee Arthroplasty
    Vanlommel, Jan
    Luyckx, Jean Philippe
    Labey, Luc
    Innocenti, Bernardo
    De Corte, Ronny
    Bellemans, Johan
    JOURNAL OF ARTHROPLASTY, 2011, 26 (03) : 492 - 496
  • [48] Conventional or navigated total knee arthroplasty affects sagittal component alignment
    Sugama, Ryo
    Minoda, Yukihide
    Kobayashi, Akio
    Iwaki, Hiroyoshi
    Ikebuchi, Mitsuhiko
    Takaoka, Kunio
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (12) : 2454 - 2459
  • [49] Current review of surgical management options for rotational alignment of the femoral and tibial component in total knee replacement
    Cretu, Bogdan
    Cirstoiu, Catalin
    Cristea, Stefan
    ROMANIAN JOURNAL OF MILITARY MEDICINE, 2019, 122 (02) : 16 - 20
  • [50] Finite element analysis of the tibial component alignment in a transverse plane in total knee arthroplasty
    Popescu, Roman
    Cristea, Stefan
    Oleksik, Valentin
    Pascu, Adrian Marius
    Haritinian, Emil George
    JOURNAL OF APPLIED BIOMEDICINE, 2021, 19 (04) : 234 - 239