A new technique for determining the rotational alignment of the tibial component during total knee arthroplasty

被引:4
|
作者
Kawaguchi, Kohei [1 ]
Inui, Hiroshi [1 ]
Yamagami, Ryota [1 ]
Kenichi, Kono [1 ]
Sameshima, Shin [1 ]
Kage, Tomofumi [1 ]
Taketomi, Shuji [1 ]
Tanaka, Sakae [1 ]
机构
[1] Tokyo Univ Hosp, Dept Orthopaed, Tokyo, Japan
关键词
Tibial component rotation; Range of motion technique; Total knee arthroplasty; Navigation system; Akagi's line; REPLACEMENT; KINEMATICS;
D O I
10.1016/j.knee.2021.02.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We evaluated the effectiveness of our new technique "Range of motion-anatomical (ROM-A) technique" which is the combination of the self-positioning technique "Range of motion (ROM) technique" and the anatomical landmarks technique in determining the tibial component (TC) rotation alignment in total knee arthroplasty (TKA) using a navigation system. Methods: This retrospective study included 103 knees who underwent TKA. The ROM-A technique was consisted of two steps. First, the TC was set and marked by the ROM technique in knee extension. Second, the TC was set according to the marking in the knee flexion and the component rotational angle relative to the anatomical tibial anteroposterior (AP) axis was adjusted between 0 degrees and 10 degrees external rotation using the navigation system. The rotational angle of TC relative to the anatomical AP axis was measured using postoperative computed tomography. Moreover, the hypothetical rotational angle of the TC in the ROM technique was calculated only from the intraoperative difference between the two techniques. Results: The actual rotational angle by the ROM-A technique was externally rotated 3.0 degrees, and the rotational outlier occurred in 3.0%. A significant difference in outlier rate was observed between the two techniques (p = 0.03). The hypothetical rotational angle of TC determined by the ROM technique (the first step only in the ROM-A technique) was externally rotated 4.6 degrees and the TC rotational outlier (difference to AP axis: >10 degrees) occurred in 11.7%. Conclusion: Using the ROM-A technique, the TC was finally fixed in almost all targeted rotational positions, and this technique could reduce the anatomical rotational outlier compared with the ROM technique. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [31] Optimal rotational positioning of tibial component in total knee arthroplasty: determined by linker surgical technique using a high definition CT
    Jung, Woon-Hwa
    Seo, Jai-Gon
    Kim, Dong Hyun
    Balabadra, Suryamanikanta
    Mandot, Utkrisht
    Kumar, Dinesh
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (03) : 401 - 408
  • [32] Functional Outcome and Rotational Alignment of Femoral Component in Unnavigated Total Knee Arthroplasty
    Madhukar, Vignesh D.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (04): : 476 - 487
  • [33] Tibial component rotation in total knee arthroplasty
    Feczko, Peter Z.
    Pijls, Bart G.
    van Steijn, Michael J.
    van Rhijn, Lodewijk W.
    Arts, Jacobus J.
    Emans, Peter J.
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [34] Rotational alignment in total knee arthroplasty
    Cho, Yool
    Lee, Myung Chul
    ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2014, 1 (04): : 113 - 118
  • [35] Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
    Florian Geiger
    Dominik Parsch
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 267 - 270
  • [36] A clinical study of the rotational alignment of the femoral component in total knee arthroplasty
    Ding, Liangjia
    Liu, Xiaomin
    Liu, Changlu
    Liu, Yingli
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (07) : 2077 - 2081
  • [37] Tibial base design and patient morphology affecting tibial coverage and rotational alignment after total knee arthroplasty
    Clary, Chadd
    Aram, Luke
    Deffenbaugh, Daren
    Heldreth, Mark
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (12) : 3012 - 3018
  • [38] Tibial Component Alignment After Total Knee Arthroplasty with Intramedullary Instrumentation: A Prospective Analysis
    Talmo, Carl T.
    Cooper, Andrew J.
    Wuerz, Tom
    Lang, Jason E.
    Bono, James V.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08) : 1209 - 1215
  • [39] Intraoperative assessment of femoral component rotational alignment in total knee arthroplasty
    Geiger, Florian
    Parsch, Dominik
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (03) : 267 - 270
  • [40] Tibial sagittal and rotational alignment reduce patellofemoral stresses in posterior stabilized total knee arthroplasty
    Mizu-Uchi, Hideki
    Ma, Yuan
    Ishibashi, Shojiro
    Colwell, Clifford W., Jr.
    Nakashima, Yasuharu
    D'Lima, Darryl D.
    SCIENTIFIC REPORTS, 2022, 12 (01)