A new technique for determining the rotational alignment of the tibial component during total knee arthroplasty

被引:4
|
作者
Kawaguchi, Kohei [1 ]
Inui, Hiroshi [1 ]
Yamagami, Ryota [1 ]
Kenichi, Kono [1 ]
Sameshima, Shin [1 ]
Kage, Tomofumi [1 ]
Taketomi, Shuji [1 ]
Tanaka, Sakae [1 ]
机构
[1] Tokyo Univ Hosp, Dept Orthopaed, Tokyo, Japan
关键词
Tibial component rotation; Range of motion technique; Total knee arthroplasty; Navigation system; Akagi's line; REPLACEMENT; KINEMATICS;
D O I
10.1016/j.knee.2021.02.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We evaluated the effectiveness of our new technique "Range of motion-anatomical (ROM-A) technique" which is the combination of the self-positioning technique "Range of motion (ROM) technique" and the anatomical landmarks technique in determining the tibial component (TC) rotation alignment in total knee arthroplasty (TKA) using a navigation system. Methods: This retrospective study included 103 knees who underwent TKA. The ROM-A technique was consisted of two steps. First, the TC was set and marked by the ROM technique in knee extension. Second, the TC was set according to the marking in the knee flexion and the component rotational angle relative to the anatomical tibial anteroposterior (AP) axis was adjusted between 0 degrees and 10 degrees external rotation using the navigation system. The rotational angle of TC relative to the anatomical AP axis was measured using postoperative computed tomography. Moreover, the hypothetical rotational angle of the TC in the ROM technique was calculated only from the intraoperative difference between the two techniques. Results: The actual rotational angle by the ROM-A technique was externally rotated 3.0 degrees, and the rotational outlier occurred in 3.0%. A significant difference in outlier rate was observed between the two techniques (p = 0.03). The hypothetical rotational angle of TC determined by the ROM technique (the first step only in the ROM-A technique) was externally rotated 4.6 degrees and the TC rotational outlier (difference to AP axis: >10 degrees) occurred in 11.7%. Conclusion: Using the ROM-A technique, the TC was finally fixed in almost all targeted rotational positions, and this technique could reduce the anatomical rotational outlier compared with the ROM technique. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [21] Variability of the location of the tibial tubercle affects the rotational alignment of the tibial component in kinematically aligned total knee arthroplasty
    Howell, Stephen M.
    Chen, Justin
    Hull, Maury L.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2288 - 2295
  • [22] Component rotational alignment in unexplained painful primary total knee arthroplasty
    Bell, Stuart W.
    Young, Peter
    Drury, Colin
    Smith, Jules
    Anthony, Iain
    Jones, Bryn
    Blyth, Mark
    McLean, Angus
    KNEE, 2014, 21 (01) : 272 - 277
  • [23] Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty
    Joong Il Kim
    Jak Jang
    Ki Woong Lee
    Hyuk Soo Han
    Sahnghoon Lee
    Myung Chul Lee
    BMC Musculoskeletal Disorders, 18
  • [24] Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty
    Kim, Joong Il
    Jang, Jak
    Lee, Ki Woong
    Han, Hyuk Soo
    Lee, Sahnghoon
    Lee, Myung Chul
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [25] Knee alignment in the transverse plane during weight-bearing activity and its implication for the tibial rotational alignment in total knee arthroplasty
    Yin, Li
    Chen, Kaining
    Guo, Lin
    Cheng, Liangjun
    Wang, Fuyou
    Yang, Liu
    CLINICAL BIOMECHANICS, 2015, 30 (06) : 565 - 571
  • [26] Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver study
    Rossi, Roberto
    Bruzzone, Matteo
    Bonasia, Davide Edoardo
    Marmotti, Antonio
    Castoldi, Filippo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (07) : 889 - 893
  • [27] Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver study
    Roberto Rossi
    Matteo Bruzzone
    Davide Edoardo Bonasia
    Antonio Marmotti
    Filippo Castoldi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 889 - 893
  • [28] Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border
    Luetzner, Joerg
    Krummenauer, Frank
    Guenther, Klaus-Peter
    Kirschner, Stephan
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [29] Rotational alignment of the tibial component in total knee arthroplasty is better at the medial third of tibial tuberosity than at the medial border
    Jörg Lützner
    Frank Krummenauer
    Klaus-Peter Günther
    Stephan Kirschner
    BMC Musculoskeletal Disorders, 11
  • [30] Femoral Anterior Tangent Line of the Osteoarthritic Knee for Determining Rotational Alignment of the Femoral Component in Total Knee Arthroplasty
    Watanabe, Hiroki
    Gejo, Ryuichi
    Matsuda, Yoshikazu
    Tatsumi, Ichiro
    Hirakawa, Kazuo
    Kimura, Tomoatsu
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02) : 268 - 273