Simultaneous analysis of naproxen, nabumetone and its major metabolite 6-methoxy-2-naphthylacetic acid in pharmaceuticals and human urine by high-performance liquid chromatography

被引:82
作者
Mikami, E
Goto, T
Ohno, T
Matsumoto, H
Nishida, M
机构
[1] Aichi Prefectural Inst Publ Hlth, Kita Ku, Nagoya, Aichi 4628576, Japan
[2] Meijo Univ, Fac Pharm, Tempaku Ku, Nagoya, Aichi 4688503, Japan
关键词
naproxen; nabumetone; 6-methoxy-2-naphthylacetic acid; pharmaceuticals; human urine; solid-phase extraction;
D O I
10.1016/S0731-7085(00)00365-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-performance liquid chromatographic (HPLC) method for simultaneous determination of naproxen (NAP), nabumetone (NAB) and its major metabolite, 6-methoxy-2-naphthylacetic acid (B-MNA), was developed for the application to pharmaceuticals and human urine. Isocratic reversed-phase HPLC was employed for quantitative analysis using triethylamine and 1-heptanesulfonic acid sodium salt (HSA) as ion-pair reagents. Urine samples were purified by solid-phase extraction using Bond-Elut Certify II cartridges containing reversed-phase and anion exchange functionalities. The HPLC assay was carried out using a Wakosil ODS 5C18 column (5 mu m, 150 x 4.6 mm, i.d.). The mobile phase consisted of 0.5 g of HSA dissolved in 1000 mi of a mixture of acetonitrile: water and triethylamine (500:500:1, v/v) adjusted with phosphoric acid to pH 3. The calibration curves of NAP and NAB showed good linearity in the concentration range 32-160 mu g/ml with UV detection (270 nm) for pharmaceuticals. In the low concentration ranges (8-96 ng of NAP per mi, 24-288 ng of NAB per mi and 5.6-67.2 ng of 6-MNA per mi), the calibration curves were also obtained with fluorimetric detection (excitation 280 nm, emission 350 nm) for biological fluids. The correlation coefficients were better than 0.999 in all cases. The lower limits of detection (defined as a signal-to-noise ratio of about 3) were approximately 0.3 ng for NAP, 1.5 ng for NAB and 0.2 ng for 6-MNA. The procedure described here is rapid, simple, selective, and is suitable for routine analysis of pharmaceuticals and pharmacokinetic studies in human urine samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:917 / 925
页数:9
相关论文
共 42 条
  • [31] Application of ultrasound-assisted emulsification microextraction for simultaneous determination of aminophenol isomers in human urine, hair dye, and water samples using high-performance liquid chromatography
    Asghari, Alireza
    Fazl-Karimi, Hamidreza
    Barfi, Behruz
    Rajabi, Maryam
    Daneshfar, Ali
    HUMAN & EXPERIMENTAL TOXICOLOGY, 2014, 33 (08) : 863 - 872
  • [32] Development and validation of a high-performance liquid chromatographic method with a fluorescence detector for the analysis of epirubicin in human urine and plasma, and its application in drug monitoring
    Treder, Natalia
    Maliszewska, Olga
    Oledzka, Ilona
    Kowalski, Piotr
    Miekus, Natalia
    Baczek, Tomasz
    Bien, Ewa
    Krawczyk, Malgorzata Anna
    Adamkiewicz-Droiynska, Elibieta
    Plenis, Alina
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1136
  • [33] Fluorometric determination of pantothenic acid in human urine by isocratic reversed-phase ion-pair high-performance liquid chromatography with post-column derivatization
    Takahashi, Kei
    Fukuwatari, Tsutomu
    Shibata, Katsumi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (22): : 2168 - 2172
  • [34] Sensitive and Selective Reversed-Phase High Performance Liquid Chromatographic-UV Spectrophotometric Determination of Dextromethorphan and its CYP2D6 Mediated Metabolite, Dextrorphan in Human Urine
    Ebeshi, Benjamin U.
    Obodozie, Obiageri O.
    Bolaji, Oluseye O.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2014, 13 (02) : 281 - 286
  • [35] Magnet integrated fabric phase sorptive extraction of selected endocrine disrupting chemicals from human urine followed by high-performance liquid chromatography - photodiode array analysis
    Alampanos, Vasileios
    Kabir, Abuzar
    Furton, Kenneth
    Samanidou, Victoria
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1654
  • [36] Three-phase hollow-fiber microextraction combined with ion-pair high-performance liquid chromatography for the simultaneous determination of five components of compound α-ketoacid tablets in human urine
    Pan, Zaifa
    Huang, Xiaoya
    Zhong, Yuan
    Wang, Lili
    Zhu, Danhua
    Li, Lanjuan
    JOURNAL OF SEPARATION SCIENCE, 2015, 38 (09) : 1499 - 1506
  • [37] Simultaneous determination of seven metabolites of organophosphate esters and 8-hydroxy-2′-deoxyguanosine in urine by high-performance liquid chromatography-tandem mass spectrometry with homemade mixed column purification
    Li Dong
    Zhang Qin
    Zhang Shenghu
    Xu Cheng
    Chen Jianqiu
    Liu Yanhua
    Song Ninghui
    Guo Ruixin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (06) : 647 - 654
  • [38] A highly sensitive assay for the simultaneous determination of morphine, morphine-3-glucuronide, and morphine-6-glucuronide in human plasma by high-performance liquid chromatography with electrochemical and fluorescence detection
    Rotshteyn, Y
    Weingarten, B
    THERAPEUTIC DRUG MONITORING, 1996, 18 (02) : 179 - 188
  • [40] Simultaneous quantification of acetaminophen and five acetaminophen metabolites in human plasma and urine by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry: Method validation and application to a neonatal pharmacokinetic study
    Cook, Sarah F.
    King, Amber D.
    van den Anker, John N.
    Wilkins, Diana G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1007 : 30 - 42