MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears

被引:20
|
作者
Kowalchuk, RM
Kneeland, JB
Dalinka, MK
Siegelman, ES
Dockery, WD
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Rochester, Sch Med & Dent, Rochester, NY USA
关键词
magnetic resonance imaging; comparative studies knee; menisci; knee; MRI; meniscal tears;
D O I
10.1007/s002560000212
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. Fast spin-echo (FSE) sequences reduce imaging time compared with conventional spin-echo (CSE) sequences, but may result in blurring. Highperformance gradients permit shorter interecho spacing and use of the second echo as the effective TE (20 ms); both improvements reduce blurring. This randomized observer study compared a short TE, second-echo FSE sequence obtained using high-performance gradients and a CSE sequence with similar TR/TE for the detection of meniscal tears in the knee. Design and patients. One hundred consecutive MR examinations of the knee using FSE and CSE sequences at 1.5 T were evaluated. The FSE sequence used an effective TE of 20 ms (centered on the second echo at 2 times minimal interecho spacing) and an echo train length of 4. FSE and CSE parameters were otherwise similar. Four independent, masked readers reviewed randomized sagittal FSE and CSE sequences. Results. Cases were assessed for the presence or absence of meniscal tears and, if present, whether tears were medial or lateral and anterior or posterior. Sequence concordance was 93.5% (1496 of 1600 meniscal segments); the intermethod kappa value was 0.78. Sequence quality was graded from 1 to 5. Average quality of CSE images was slightly but statistically significantly preferred by three of the four readers. Conclusion. There was no statistically significant difference between CSE imaging and FSE imaging centered on the second echo (20 ms) using high-performance gradients for the detection of meniscal tears in the knee. There was a small preference for the quality of CSE images.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 50 条
  • [41] Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequence
    Lee, Seung Hyun
    Lee, Young Han
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2018, 46 : 90 - 97
  • [42] Incidental magnetization transfer contrast in fast spin-echo imaging of cartilage
    Yao, L
    Gentili, A
    Thomas, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) : 180 - 184
  • [43] Fast T2 mapping using multi-echo spin-echo MRI: A linear order approach
    Fatemi, Yaghoub
    Danyali, Habibollah
    Helfroush, Mohammad Sadegh
    Amiri, Houshang
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (05) : 2815 - 2830
  • [44] High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
    Gao, Feifei
    Wen, Zejun
    Dou, Shewei
    Kan, Xiaojing
    Wei, Shufang
    Ge, Yinghui
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [45] MRI MEASUREMENTS OF THE DEPENDENCE ON T-1 OF THE ECHO AMPLITUDES USING A MULTIPLE SPIN-ECHO SCHEME
    FRANSSON, A
    ERICSSON, A
    SPERBER, GO
    MAGNETIC RESONANCE IMAGING, 1993, 11 (08) : 1185 - 1192
  • [46] Spin-echo and 3D gradient-echo imaging of the knee joint: A clinical and histopathological comparison
    Guckel, C
    Jundt, G
    Schnabel, K
    Gachter, A
    EUROPEAN JOURNAL OF RADIOLOGY, 1995, 21 (01) : 25 - 33
  • [47] HIGH-RESOLUTION SPIN-ECHO IMAGING OF THE TEMPOROMANDIBULAR-JOINT
    RAO, VM
    VINITSKI, S
    MAGNETIC RESONANCE IMAGING, 1993, 11 (05) : 621 - 624
  • [48] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [49] Isotropic diffusion weighting in radial fast spin-echo magnetic resonance imaging
    Sarlls, JE
    Newbould, RD
    Altbach, MI
    Gmitro, AF
    Seeger, J
    Trouard, TP
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1347 - 1354
  • [50] Keyhole diffusion tensor imaging - a fast spin-echo based DTI technique
    Chu, W. C.
    Chen, Y. R.
    Chou, K. S.
    Chen Po-Chou
    Sun, S. W.
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 43 - +