MRI of the knee: value of short echo time fast spin-echo using high performance gradients versus conventional spin-echo imaging for the detection of meniscal tears

被引:20
|
作者
Kowalchuk, RM
Kneeland, JB
Dalinka, MK
Siegelman, ES
Dockery, WD
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] Univ Rochester, Sch Med & Dent, Rochester, NY USA
关键词
magnetic resonance imaging; comparative studies knee; menisci; knee; MRI; meniscal tears;
D O I
10.1007/s002560000212
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective. Fast spin-echo (FSE) sequences reduce imaging time compared with conventional spin-echo (CSE) sequences, but may result in blurring. Highperformance gradients permit shorter interecho spacing and use of the second echo as the effective TE (20 ms); both improvements reduce blurring. This randomized observer study compared a short TE, second-echo FSE sequence obtained using high-performance gradients and a CSE sequence with similar TR/TE for the detection of meniscal tears in the knee. Design and patients. One hundred consecutive MR examinations of the knee using FSE and CSE sequences at 1.5 T were evaluated. The FSE sequence used an effective TE of 20 ms (centered on the second echo at 2 times minimal interecho spacing) and an echo train length of 4. FSE and CSE parameters were otherwise similar. Four independent, masked readers reviewed randomized sagittal FSE and CSE sequences. Results. Cases were assessed for the presence or absence of meniscal tears and, if present, whether tears were medial or lateral and anterior or posterior. Sequence concordance was 93.5% (1496 of 1600 meniscal segments); the intermethod kappa value was 0.78. Sequence quality was graded from 1 to 5. Average quality of CSE images was slightly but statistically significantly preferred by three of the four readers. Conclusion. There was no statistically significant difference between CSE imaging and FSE imaging centered on the second echo (20 ms) using high-performance gradients for the detection of meniscal tears in the knee. There was a small preference for the quality of CSE images.
引用
收藏
页码:520 / 524
页数:5
相关论文
共 50 条
  • [31] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Wolff, Andrew B.
    Pesce, Lorenzo L.
    Wu, Jim S.
    Smart, L. Ryan
    Medvecky, Michael J.
    Haims, Andrew H.
    SKELETAL RADIOLOGY, 2009, 38 (01) : 21 - 29
  • [32] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Andrew B. Wolff
    Lorenzo L. Pesce
    Jim S. Wu
    L. Ryan Smart
    Michael J. Medvecky
    Andrew H. Haims
    Skeletal Radiology, 2009, 38 : 21 - 29
  • [33] Comparison of T2-weighted fast spin-echo and spin-echo MR sequences in the detection of brain lesions of multiple sclerosis
    Sparacia, G
    Angileri, T
    Accardi, M
    Pappalardo, S
    Sarno, C
    DeMaria, M
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 233 - 235
  • [34] Knee Imaging: Rapid Three-Dimensional Fast Spin-Echo Using Compressed Sensing
    Kijowski, Richard
    Rosas, Humberto
    Samsonov, Alexey
    King, Kevin
    Peters, Rob
    Liu, Fang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (06) : 1712 - 1722
  • [35] MRI of the lung: Value of different turbo spin-echo, single-shot turbo spin-echo, and 3D gradient-echo pulse sequences for the detection of pulmonary metastases
    Bruegel, Melanie
    Gaa, Jochen
    Woertler, Klaus
    Ganter, Carl
    Waldt, Simone
    Hillerer, Claudia
    Rummeny, Ernst J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 73 - 81
  • [36] Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): Initial experience
    Gold, Garry E.
    Busse, Reed F.
    Beehler, Carol
    Han, Eric
    Brau, Anja C. S.
    Beatty, Philip J.
    Beaulieu, Christopher F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) : 1287 - 1293
  • [37] A COMPARISON BETWEEN FAST AND CONVENTIONAL SPIN-ECHO IN THE DETECTION OF MULTIPLE-SCLEROSIS LESIONS
    THORPE, JW
    HALPIN, SF
    MACMANUS, DG
    BARKER, GJ
    KENDALL, BE
    MILLER, DH
    NEURORADIOLOGY, 1994, 36 (05) : 388 - 392
  • [38] STEREOTAXIC LOCALIZATION USING FAST SPIN-ECHO IMAGING IN FUNCTIONAL-DISORDERS
    TAREN, JA
    ROSS, DA
    GEBARSKI, SS
    ACTA NEUROCHIRURGICA, 1993, : 59 - 60
  • [39] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    I-Hua Huang
    Kathleen H. Emery
    Tal Laor
    Mona Valentine
    Jan Tiefermann
    Pediatric Radiology, 2008, 38 : 675 - 679
  • [40] Fast-recovery fast spin-echo T2-weighted MR imaging: a free-breathing alternative to fast spin-echo in the pediatric abdomen
    Huang, I-Hua
    Emery, Kathleen H.
    Laor, Tal
    Valentine, Mona
    Tiefermann, Jan
    PEDIATRIC RADIOLOGY, 2008, 38 (06) : 675 - 679