An ultrasensitive electrochemical immunosensor platform based on disposable ITO electrode modified by 3-CPTMS for early detection of parathyroid hormone

被引:7
作者
Uludag, Inci [1 ]
Sezginturk, Mustafa Kemal [1 ]
机构
[1] Canakkale Onsekiz Mart Univ, Fac Engn, Dept Bioengn, Canakkale, Turkey
关键词
Biosensor; disposable immunosensor; ITO-PET electrode; parathyroid hormone; 3-CPTMS; VITAMIN-D; BIOSENSOR; SENSOR;
D O I
10.3906/kim-1909-44
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Parathyroid hormone (PTH) is a polypeptide containing 84 amino acids secreted by cells of the parathyroid glands. Imbalances of parathyroid levels cause medical problems such as osteoporosis, mental disorders, pancreatitis, kidney stones, cancer, and other symptoms. In this study, we aimed to design an ultrasensitive electrochemical immunosensor for PTH detection. Indium tin oxide (ITO) was used as an electrode for electrochemical impedance spectroscopy (EIS) measurements. ITO sheets were modified by using 3-cyanopropyltrimethoxysilane (3-CPTMS) self-assembled monolayers (SAMs) for immobilizing the anti-PTH antibody via covalent interactions. Cyclic voltammetry (CV) and EIS methods were applied to characterize immobilization steps. Therefore, 1% was selected for an optimal concentration of silane, 10 ng/mL was selected as an optimal concentration of anti-PTH, and 30 and 45 min were selected as optimal incubation times for anti-PTH and PTH, respectively. PTH antigen was determined in the concentration range from 0.05 fg/mL to 150 fg/mL. To detect the analytical characterization of the 3-CPTMS modified immunosensor, linear range, repeatability, reproducibility, Kramers-Kronig transform, and regeneration studies were performed. Also, the shelf life of the developed biosensor was investigated. Finally, real human serum samples were analyzed with the PTH immunosensor. The results showed that the designed biosensor system has high potential for early detection for medical treatments.
引用
收藏
页码:1697 / 1710
页数:14
相关论文
共 50 条
[21]   Ultrasensitive Immunosensor for Aflatoxin B1 Detection Based on Screen-Printed Carbon Electrode Modified by Ferrocene@Multi-Walled Carbon Nanotubes [J].
Zhang, Hui ;
Shi, Zhaoqiang ;
Cheng, Shuting ;
Yang, Qingqing ;
Sun, Xia ;
Guo, Yemin .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (09) :9170-9180
[22]   A novel electrochemical immunosensor based on Fe3O4@graphene nanocomposite modified glassy carbon electrode for rapid detection of Salmonella in milk [J].
Feng, Kaiwen ;
Li, Ting ;
Ye, Cuizhu ;
Gao, Xiaoyu ;
Yue, Xianglin ;
Ding, Shuangyan ;
Dong, Qiuling ;
Yang, Mingqi ;
Huang, Ganhui ;
Zhang, Jinsheng .
JOURNAL OF DAIRY SCIENCE, 2022, 105 (03) :2108-2118
[23]   Rapid detection of Salmonella in milk by a label-free electrochemical immunosensor based on CoFe-MOFs@MWCNTs modified electrode [J].
Li, Huo ;
Huang, Side ;
Ling, Tiandi ;
Li, Shuang ;
Zhang, Yu ;
Ying, Yue ;
Huang, Ganhui ;
Zhang, Jinsheng .
INTERNATIONAL DAIRY JOURNAL, 2025, 166
[24]   Ultrasensitive and Selective Electrochemical Detection of Dopamine Based on CuO/PVA Nanocomposite-Modified GC Electrode [J].
Azharudeen, A. Mohamed ;
Roy, Arpita ;
Karthiga, R. ;
Prabhu, S. Arun ;
Prakash, M. G. ;
Badhusha, A. Mohamed Ismail ;
Ali, Huma ;
Katubi, Khadijah Mohammedsaleh ;
Islam, Md Rabiul .
INTERNATIONAL JOURNAL OF PHOTOENERGY, 2022, 2022
[25]   Electrochemical aptasensor based on carboxylated graphene oxide modified carbon paste electrode for strontium ultrasensitive detection [J].
Ebrahimi, Nastaran ;
Raoof, Jahan Bakhsh ;
Ojani, Reza ;
Ebrahimi, Maryam .
ANALYTICAL BIOCHEMISTRY, 2023, 666
[26]   Rapid detection of Salmonella in milk by labeling-free electrochemical immunosensor based on an Fe3O4-ionic liquid-modified electrode [J].
Li, Shuang ;
Zhang, Yu ;
Guo, Mengdi ;
Yi, Zhibin ;
Hu, Mengna ;
Xiong, Chunhong ;
Huang, Ganhui ;
Zhang, Jinsheng .
TALANTA, 2024, 270
[27]   Disposable integrated bismuth citrate-modified screen-printed immunosensor for ultrasensitive quantum dot-based electrochemical assay of C-reactive protein in human serum [J].
Kokkinos, Christos ;
Prodromidis, Mamas ;
Economou, Anastasios ;
Petrou, Panagiota ;
Kakabakos, Sotirios .
ANALYTICA CHIMICA ACTA, 2015, 886 :29-36
[28]   Electrochemical immunosensor for Enterobacter sakazakii detection based on electrochemically reduced graphene oxide-gold nanoparticle/ionic liquid modified electrode [J].
Hu, Xue ;
Dou, Wenchao ;
Zhao, Guangying .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 756 :43-48
[29]   An ultrasensitive disposable sandwich-configuration electrochemical immunosensor based on OMC@AuNPs composites and AuPt-MB for alpha-fetoprotein detection [J].
Rong, Shengzhong ;
Zou, Lina ;
Li, Yang ;
Guan, Yue ;
Guan, Huilin ;
Zhang, Ze ;
Zhang, Yingcong ;
Gao, Hongmin ;
Yu, Hongwei ;
Zhao, Fuyang ;
Pan, Hongzhi ;
Chang, Dong .
BIOELECTROCHEMISTRY, 2021, 141
[30]   Sensitive electrochemical detection of fenitrothion pesticide based on self-assembled peptide-nanotubes modified disposable pencil graphite electrode [J].
Bolat, Gulcin ;
Abaci, Serdar ;
Vural, Tayfun ;
Bozdogan, Betul ;
Denkbas, Emir B. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 809 :88-95